1.
Water Res ; 43(5): 1370-80, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19138781

RESUMO

Lagrangian actinometry (LA) has been demonstrated to represent an alternative to conventional biodosimetry for validation of ultraviolet (UV) disinfection systems used in drinking water treatment. However, previous applications of LA for this purpose have all involved monochromatic (lambda = 254 nm) UV reactor systems. To address this issue, dyed microspheres (DMS) were applied for quantification of dose distribution delivery by field-scale UV reactor systems based on medium-pressure Hg lamp (MP) technology. These MP reactor systems are characterized by polychromatic output. Dose distribution estimates developed by LA for these reactors were reported as equivalent 254 nm distributions. When combined with the UV(254) dose-response behavior for challenge organisms used in simultaneous or parallel biodosimetry experiments, the dose distribution estimates developed from the microspheres yielded estimates of challenge organism inactivation that were in agreement with measured values. For one of the reactors tested, biodosimetry tests were conducted with two challenge organisms that had different UV dose-response behavior; UV dose distribution estimates from LA yielded predictions of microbial inactivation that were in agreement with measured inactivation responses for both challenge organisms for all test conditions. It is likely that the agreement between LA results and biodosimetry data was related, in part, to the agreement between the action spectra of the microspheres and the challenge organisms. Because LA yields a measure of the UV dose distribution delivered by a reactor, the information from LA assays will eliminate many sources of uncertainty in the design and operation of UV systems, thereby allowing for implementation of UV reactor systems that are less expensive than their predecessors, yet more reliable.


Assuntos
Reatores Biológicos/virologia , Corantes/química , Desinfecção/métodos , Microesferas , Pressão , Raios Ultravioleta , Relação Dose-Resposta à Radiação , Fluorescência , Levivirus/isolamento & purificação , Levivirus/efeitos da radiação , Viabilidade Microbiana/efeitos da radiação , Reprodutibilidade dos Testes
2.
Water Res ; 42(3): 677-88, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17888484

RESUMO

Dyed microspheres have been developed as a new method for validation of ultraviolet (UV) reactor systems. When properly applied, dyed microspheres allow measurement of the UV dose distribution delivered by a photochemical reactor for a given operating condition. Prior to this research, dyed microspheres had only been applied to a bench-scale UV reactor. The goal of this research was to extend the application of dyed microspheres to large-scale reactors. Dyed microsphere tests were conducted on two prototype large-scale UV reactors at the UV Validation and Research Center of New York (UV Center) in Johnstown, NY. All microsphere tests were conducted under conditions that had been used previously in biodosimetry experiments involving two challenge bacteriophage: MS2 and Qbeta. Numerical simulations based on computational fluid dynamics and irradiance field modeling were also performed for the same set of operating conditions used in the microspheres assays. Microsphere tests on the first reactor illustrated difficulties in sample collection and discrimination of microspheres against ambient particles. Changes in sample collection and work-up were implemented in tests conducted on the second reactor that allowed for improvements in microsphere capture and discrimination against the background. Under these conditions, estimates of the UV dose distribution from the microspheres assay were consistent with numerical simulations and the results of biodosimetry, using both challenge organisms. The combined application of dyed microspheres, biodosimetry, and numerical simulation offers the potential to provide a more in-depth description of reactor performance than any of these methods individually, or in combination. This approach also has the potential to substantially reduce uncertainties in reactor validation, thereby leading to better understanding of reactor performance, improvements in reactor design, and decreases in reactor capital and operating costs.


Assuntos
Desinfecção/instrumentação , Microesferas , Raios Ultravioleta , Purificação da Água/instrumentação , Allolevivirus/efeitos da radiação , Corantes , Desinfecção/métodos , Escherichia coli/virologia , Levivirus/efeitos da radiação , Poliestirenos , Estreptavidina , Poluentes da Água/efeitos da radiação , Purificação da Água/métodos , Abastecimento de Água