Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Artigo em Alemão | MEDLINE | ID: mdl-36958311

RESUMO

The still unchanged high morbidity and mortality of patients undergoing complex cardiac surgical procedures as well as developments in minimally invasive cardiac surgery are not only an ongoing challenge for all working in cardiac anaesthesia but also a chance for further developing this anaesthetic subdiscipline. Alongside the presentation of a case report, the present article gives an overview about recent developments in inotropic therapy, monitoring, the rational use of mechanical circulatory support, volume therapy, sedation, analgesia, and point-of-care coagulation monitoring in cardiac anaesthesia.


Assuntos
Analgesia , Anestesia , Anestésicos , Humanos , Anestesia/métodos
3.
J Clin Monit Comput ; 37(3): 735-742, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36607531

RESUMO

This prospective method comparison study compared cerebral oxygen saturation (ScO2) measurement performance of the new cerebral oximeter (NeurOs®, Mespere LifeSciences, Ontario, Canada) in comparison to the established INVOS 5100C® (Medtronic, Boulder, USA) cerebral oximeter. We performed measurements during different levels of carbon dioxide pressure (PaCO2) during hyper- and hypoventilation and different levels of arterial oxygen saturation (SaO2) induced by variation of the inspiratory fraction of oxygen (FiO2). 59 anesthetized cardiac and vascular surgical patients were studied during hemodynamically stable conditions. Two versions of the NeurOs® oximeter were used in 39 and 20 patients, respectively: an older version with one bi-hemispherical sensor attached to the midline of the forehead and a newer version with two sensors that were attached to the left and right forehead. Alternating measurements of ScO2 with the INVOS® oximeter (bifrontal sensors) and the NeurOs® oximeter were performed during baseline conditions and after PaCO2 had been randomly in- and decreased by changes in ventilation (constant FiO2) and SaO2 had been randomly modified by variations in FiO2 (constant PaCO2). Employing the most recent NeurOs® version, measurements were additionally performed in a default and a high penetration mode. Bland-Altman analyses revealed comparable bias and limits of agreement for INVOS® and NeurOS® measurements during baseline conditions when using the bi-hemispherical sensor and the version with two sensors, respectively. Consequently, further analyses were performed on the pooled data of 59 patients. Bland-Altman analysis for repeated measurements revealed a bias of - 0.5%, a lower limit of agreement of - 16.3% (95% CI - 19.6 to - 13.7%) and an upper limit of agreement of 15.4% (95% CI 12.8 to 18.8%) during variations of PaCO2. The respective analysis during changes in SaO2 induced by variation of the FiO2 revealed a bias of - 0.8%, a lower limit of agreement of - 16.3% (95% CI - 19.7 to - 13.6%) and an upper limit of agreement of 14.7% (95% CI 12.1 to 18.2%). Both analyses showed a proportional error. No significant differences in ScO2 were observed during measurements with the bi-frontal sensors in the default as well as the high penetration mode. The ScO2 measurement performance of the NeurOs® cerebral oximeter is not interchangeable with the INVOS® cerebral oximeter during variations of ventilation and oxygenation in elective cardiac or vascular surgical patients. The lack of reactivity to changes in ventilation (by variation of PaCO2) and oxygen delivery (by variation of FiO2) question the reliability of NeurOs® measurements to reflect changes in cerebral blood flow and cerebral oxygen balance. This holds true not only for different sensor positions at the forehead but also for different modes of penetration.


Assuntos
Dióxido de Carbono , Oxigênio , Humanos , Circulação Cerebrovascular , Oximetria/métodos , Pressão Parcial , Reprodutibilidade dos Testes , Estudos Prospectivos
4.
Pflugers Arch ; 473(11): 1795-1806, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34386847

RESUMO

Functional hyperemia is fundamental to provide enhanced oxygen delivery during exercise in skeletal muscle. Different mechanisms are suggested to contribute, mediators from skeletal muscle, transmitter spillover from the neuromuscular synapse as well as endothelium-related dilators. We hypothesized that redundant mechanisms that invoke adenosine, endothelial autacoids, and KATP channels mediate the dilation of intramuscular arterioles in mice. Arterioles (maximal diameter: 20-42 µm, n = 65) were studied in the cremaster by intravital microscopy during electrical stimulation of the motor nerve to induce twitch or tetanic skeletal muscle contractions (10 or 100 Hz). Stimulation for 1-60 s dilated arterioles rapidly up to 65% of dilator capacity. Blockade of nicotinergic receptors blocked muscle contraction and arteriolar dilation. Exclusive blockade of adenosine receptors (1,3-dipropyl-8-(p-sulfophenyl)xanthine) or of NO and prostaglandins (nitro-L-arginine and indomethacin, LN + Indo) exerted only a minor attenuation. Combination of these blockers, however, reduced the dilation by roughly one-third during longer stimulation periods (> 1 s at 100 Hz). Blockade of KATP channels (glibenclamide) which strongly reduced adenosine-induced dilation reduced responses upon electrical stimulation only moderately. The attenuation was strongly enhanced if glibenclamide was combined with LN + Indo and even observed during brief stimulation. LN was more efficient than indomethacin to abrogate dilations if combined with glibenclamide. Arteriolar dilations induced by electrical stimulation of motor nerves require muscular contractions and are not elicited by acetylcholine spillover from neuromuscular synapses. The dilations are mediated by redundant mechanisms, mainly activation of KATP channels and release of NO. The contribution of K+ channels and hyperpolarization sets the stage for ascending dilations that are crucial for a coordinated response in the network.


Assuntos
Trifosfato de Adenosina/metabolismo , Arteríolas/metabolismo , Canais KATP/metabolismo , Músculo Esquelético/metabolismo , Óxido Nítrico/metabolismo , Acetilcolina/farmacologia , Adenosina/metabolismo , Animais , Arteríolas/efeitos dos fármacos , Dilatação/métodos , Estimulação Elétrica/métodos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Contração Muscular/efeitos dos fármacos , Contração Muscular/fisiologia , Músculo Esquelético/efeitos dos fármacos , Prostaglandinas/metabolismo , Vasodilatação/efeitos dos fármacos , Vasodilatação/fisiologia
5.
J Cardiothorac Vasc Anesth ; 34(10): 2674-2681, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32402699

RESUMO

OBJECTIVE: To explore the effects of fluid therapy with the synthetic colloids hydroxyethyl starch (HES) and gelatin (GEL) on the incidence of acute kidney injury (AKI) and need for renal replacement therapy (RRT) in patients undergoing cardiac surgery. DESIGN: Secondary analysis of a prospective observational study in cardiac surgical patients. DESIGN: University hospital. PARTICIPANTS: The study included 584 elective patients (excluding patients on preoperative dialysis). MEASUREMENTS AND MAIN RESULTS: Anamnestic and surgical core data, hemodynamics, and hemodynamic treatments were recorded intraoperatively and postoperatively. Postoperative kidney dysfunction was graded according to the Acute Kidney Injury Network criteria from perioperative changes in plasma creatinine and urine flow. Statistical analyses were performed descriptively, by logistic and probit regression, omitting inotropic and vasoactive medications as established renal risk factors. The incidence of AKI and new renal replacement therapy was 28.6% and 7.5%, respectively. Patients with AKI were older, had a higher additive Euroscore, lower preoperative glomerular filtration rates and hemoglobin level, and presented with a longer duration of cardiopulmonary bypass and surgery and higher postoperative drainage loss. HES (1 [0-2] units of 500 mL) and GEL (3 [2-5] units of 500 mL) were used in 317 and 563 patients, respectively. Crystalloids were used in all patients (4,560 [4,080-5,042] mL). Patients presenting with AKI or new RRT were treated with significantly higher amounts of GEL. The use of HES and crystalloids did not differ between these groups. Probit regression showed significant dose-response relationships between the amount of infused gelatin and the probability of AKI and new RRT. Probit regression showed significant (p = 0.0001 and 0.0003, respectively) dose-response relationships between the total units of gelatin polysuccinate infused and the probability of AKI and new RRT (Fig 1). Logistic regression revealed a statistically significant odds ratio (OR) of 1.9741 (95% CI: 1.3104-2.9740; p = 0.0011) for an association between the number of gelatin units infused and AKI (grade 1-3) but no direct association between the number of gelatin units administered and new RRT. No association between a decrease in kidney function and the application of HES was observed. CONCLUSIONS: Taking into account the limitations of the small sample size and a low event rate, the nonconsideration of established renal risk factors such as inotropes and vasopressors, and potentially unmeasured confounders, these findings suggested that gelatin solutions may have deleterious effects on renal function in cardiac surgical patients. The adverse clinical effects of HES on kidney function observed in other studies may have been blunted by the restrictive use of this synthetic colloid.


Assuntos
Injúria Renal Aguda , Gelatina , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Hidratação , Gelatina/efeitos adversos , Humanos , Derivados de Hidroxietil Amido/efeitos adversos , Rim , Terapia de Substituição Renal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...