1.
Phys Med ; 118: 103201, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38199179

RESUMO

PURPOSE: This work aims at studying the sensitivity of a miniaturized Tissue-Equivalent Proportional Counter to variations of beam quality in clinical radiation fields, to further investigate its performances as radiation quality monitor. METHODS: Measurements were taken at the CATANA facility (INFN-LNS, Catania, Italy), in a monoenergetic and an energy-modulated proton beam with the same initial energy of 62 MeV. PMMA layers were placed in front of the detector to measure at different depths along the depth-dose profile. The frequency- and dose-mean lineal energy were compared to the track- and dose-averaged LET calculated by Monte Carlo simulations. A microdosimetric evaluation of the Relative Biological Effectiveness (RBE) was performed and compared with cell survival experiments. RESULTS: Microdosimetric distributions measured at identical depths in the two beams show spectral differences reflecting their different radiation quality. Discrepancies are most evident at depths corresponding to the Spread-Out Bragg Peak, while spectra at the entrance and in the dose fall-off regions are similar. This can be explained by the different energy components that compose the pristine and spread-out peaks at each depth. The trend of microdosimetric mean values matches that of calculated LET averages along the entire penetration depth, and the microdosimetric estimation of RBE is consistent with radiobiological data not only at 2 Gy but also at lower dose levels, such as those absorbed by healthy tissues. CONCLUSIONS: The mini-TEPC is sensitive to differences in radiation quality resulting from different modulations of the proton beam, confirming its potential for beam quality monitoring in proton therapy.


Assuntos
Terapia com Prótons , Monitoramento de Radiação , Prótons , Radiometria/métodos , Eficiência Biológica Relativa , Método de Monte Carlo
2.
Sci Rep ; 9(1): 10837, 2019 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-31346184

RESUMO

The increased inertia of very high-energy electrons (VHEEs) due to relativistic effects reduces scattering and enables irradiation of deep-seated tumours. However, entrance and exit doses are high for collimated or diverging beams. Here, we perform a study based on Monte Carlo simulations of focused VHEE beams in a water phantom, showing that dose can be concentrated into a small, well-defined volumetric element, which can be shaped or scanned to treat deep-seated tumours. The dose to surrounding tissue is distributed over a larger volume, which reduces peak surface and exit doses for a single beam by more than one order of magnitude compared with a collimated beam.


Assuntos
Simulação por Computador , Dosagem Radioterapêutica , Radioterapia/métodos , Elétrons , Método de Monte Carlo
3.
Sci Rep ; 9(1): 4471, 2019 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-30872656

RESUMO

Protontherapy has emerged as more effective in the treatment of certain tumors than photon based therapies. However, significant capital and operational costs make protontherapy less accessible. This has stimulated interest in alternative proton delivery approaches, and in this context the use of laser-based technologies for the generation of ultra-high dose rate ion beams has been proposed as a prospective route. A better understanding of the radiobiological effects at ultra-high dose-rates is important for any future clinical adoption of this technology. In this study, we irradiated human skin fibroblasts-AG01522B cells with laser-accelerated protons at a dose rate of 109 Gy/s, generated using the Gemini laser system at the Rutherford Appleton Laboratory, UK. We studied DNA double strand break (DSB) repair kinetics using the p53 binding protein-1(53BP1) foci formation assay and observed a close similarity in the 53BP1 foci repair kinetics in the cells irradiated with 225 kVp X-rays and ultra- high dose rate protons for the initial time points. At the microdosimetric scale, foci per cell per track values showed a good correlation between the laser and cyclotron-accelerated protons indicating similarity in the DNA DSB induction and repair, independent of the time duration over which the dose was delivered.


Assuntos
Quebras de DNA de Cadeia Dupla , Fibroblastos/efeitos da radiação , Terapia com Prótons/instrumentação , Proteína 1 de Ligação à Proteína Supressora de Tumor p53/metabolismo , Linhagem Celular , Ciclotrons/instrumentação , Relação Dose-Resposta à Radiação , Fibroblastos/química , Fibroblastos/citologia , Humanos , Lasers , Estudos Prospectivos , Terapia com Prótons/efeitos adversos
4.
Braz. j. med. biol. res ; 51(1): e6258, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889008

RESUMO

The pathophysiological mechanisms associated with the effects of red blood cell (RBC) transfusion on cardiopulmonary function and inflammation are unclear. We developed an experimental model of homologous 14-days stored RBC transfusion in hypovolemic swine to evaluate the short-term effects of transfusion on cardiopulmonary system and inflammation. Sixteen healthy male anesthetized swine (68±3.3 kg) were submitted to controlled hemorrhage (25% of blood volume). Two units of non-filtered RBC from each animal were stored under blood bank conditions for 14 days. After 30 min of hypovolemia, the control group (n=8) received an infusion of lactated Ringer's solution (three times the removed volume). The transfusion group (n=8) received two units of homologous 14-days stored RBC and lactated Ringer's solution in a volume that was three times the difference between blood removed and blood transfusion infused. Both groups were followed up for 6 h after resuscitation with collection of hemodynamic and respiratory data. Cytokines and RNA expression were measured in plasma and lung tissue. Stored RBC transfusion significantly increased mixed oxygen venous saturation and arterial oxygen content. Transfusion was not associated with alterations on pulmonary function. Pulmonary concentrations of cytokines were not different between groups. Gene expression for lung cytokines demonstrated a 2-fold increase in mRNA level for inducible nitric oxide synthase and a 0.5-fold decrease in mRNA content for IL-21 in the transfused group. Thus, stored homologous RBC transfusion in a hypovolemia model improved cardiovascular parameters but did not induce significant effects on microcirculation, pulmonary inflammation and respiratory function up to 6 h after transfusion.


Assuntos
Animais , Masculino , Pneumonia/fisiopatologia , Fenômenos Fisiológicos Respiratórios , Preservação de Sangue/métodos , Fenômenos Fisiológicos Cardiovasculares , Transfusão de Eritrócitos/métodos , Hipovolemia/terapia , Suínos , Preservação de Sangue/efeitos adversos , Ensaio de Imunoadsorção Enzimática , Citocinas/sangue , Resultado do Tratamento , Transfusão de Eritrócitos/efeitos adversos , Modelos Animais de Doenças , Hemodinâmica
5.
Braz J Med Biol Res ; 51(1): e6258, 2017 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-29185590

RESUMO

The pathophysiological mechanisms associated with the effects of red blood cell (RBC) transfusion on cardiopulmonary function and inflammation are unclear. We developed an experimental model of homologous 14-days stored RBC transfusion in hypovolemic swine to evaluate the short-term effects of transfusion on cardiopulmonary system and inflammation. Sixteen healthy male anesthetized swine (68±3.3 kg) were submitted to controlled hemorrhage (25% of blood volume). Two units of non-filtered RBC from each animal were stored under blood bank conditions for 14 days. After 30 min of hypovolemia, the control group (n=8) received an infusion of lactated Ringer's solution (three times the removed volume). The transfusion group (n=8) received two units of homologous 14-days stored RBC and lactated Ringer's solution in a volume that was three times the difference between blood removed and blood transfusion infused. Both groups were followed up for 6 h after resuscitation with collection of hemodynamic and respiratory data. Cytokines and RNA expression were measured in plasma and lung tissue. Stored RBC transfusion significantly increased mixed oxygen venous saturation and arterial oxygen content. Transfusion was not associated with alterations on pulmonary function. Pulmonary concentrations of cytokines were not different between groups. Gene expression for lung cytokines demonstrated a 2-fold increase in mRNA level for inducible nitric oxide synthase and a 0.5-fold decrease in mRNA content for IL-21 in the transfused group. Thus, stored homologous RBC transfusion in a hypovolemia model improved cardiovascular parameters but did not induce significant effects on microcirculation, pulmonary inflammation and respiratory function up to 6 h after transfusion.


Assuntos
Preservação de Sangue/métodos , Fenômenos Fisiológicos Cardiovasculares , Transfusão de Eritrócitos/métodos , Hipovolemia/terapia , Pneumonia/fisiopatologia , Fenômenos Fisiológicos Respiratórios , Animais , Preservação de Sangue/efeitos adversos , Citocinas/sangue , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática , Transfusão de Eritrócitos/efeitos adversos , Hemodinâmica , Masculino , Oxigênio/metabolismo , Reprodutibilidade dos Testes , Ressuscitação/métodos , Suínos , Fatores de Tempo , Resultado do Tratamento
6.
Rev Sci Instrum ; 87(11): 111501, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910572

RESUMO

The space charge accumulation phenomenon has garnered great interest over the last two decades because of the increased use of direct current in high voltage electrical systems. In this context, a significant relevance has been achieved by the thermal methods, used for solid dielectrics. This paper presents a review of this non-destructive measurement system used for the measurement of space charge. The thermal pulse method, the thermal step method, and the laser intensity modulation method are described. For each configuration, the principle of operation, the thicknesses analyzed, and the spatial resolution are described, reporting also the main related applications.

7.
Nanotechnology ; 27(21): 215101, 2016 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-27080849

RESUMO

Radiation resistance and toxicity in normal tissues are limiting factors in the efficacy of radiotherapy. Gold nanoparticles (GNPs) have been shown to be effective at enhancing radiation-induced cell death, and were initially proposed to physically enhance the radiation dose deposited. However, biological responses of GNP radiosensitization based on physical assumptions alone are not predictive of radiosensitisation and therefore there is a fundamental research need to determine biological mechanisms of response to GNPs alone and in combination with ionising radiation. This study aimed to identify novel mechanisms of cancer cell radiosensitisation through the use of GNPs, focusing on their ability to induce cellular oxidative stress and disrupt mitochondrial function. Using N-acetyl-cysteine, we found mitochondrial oxidation to be a key event prior to radiation for the radiosensitisation of cancer cells and suggests the overall cellular effects of GNP radiosensitisation are a result of their interaction with protein disulphide isomerase (PDI). This investigation identifies PDI and mitochondrial oxidation as novel targets for radiosensitisation.


Assuntos
Acetilcisteína/farmacologia , Ouro/farmacologia , Nanopartículas Metálicas/química , Neoplasias/enzimologia , Isomerases de Dissulfetos de Proteínas/metabolismo , Radiossensibilizantes/farmacologia , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Regulação Neoplásica da Expressão Gênica/efeitos dos fármacos , Regulação Neoplásica da Expressão Gênica/efeitos da radiação , Ouro/química , Humanos , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Potencial da Membrana Mitocondrial/efeitos da radiação , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/efeitos da radiação , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia , Estresse Oxidativo/efeitos da radiação
8.
Br J Radiol ; 88(1045): 20140392, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25257709

RESUMO

Proton and ion beams are radiotherapy modalities of increasing importance and interest. Because of the different biological dose response of these radiations as compared with high-energy photon beams, the current approach of treatment prescription is based on the product of the absorbed dose to water and a biological weighting factor, but this is found to be insufficient for providing a generic method to quantify the biological outcome of radiation. It is therefore suggested to define new dosimetric quantities that allow a transparent separation of the physical processes from the biological ones. Given the complexity of the initiation and occurrence of biological processes on various time and length scales, and given that neither microdosimetry nor nanodosimetry on their own can fully describe the biological effects as a function of the distribution of energy deposition or ionization, a multiscale approach is needed to lay the foundation for the aforementioned new physical quantities relating track structure to relative biological effectiveness in proton and ion beam therapy. This article reviews the state-of-the-art microdosimetry, nanodosimetry, track structure simulations, quantification of reactive species, reference radiobiological data, cross-section data and multiscale models of biological response in the context of realizing the new quantities. It also introduces the European metrology project, Biologically Weighted Quantities in Radiotherapy, which aims to investigate the feasibility of establishing a multiscale model as the basis of the new quantities. A tentative generic expression of how the weighting of physical quantities at different length scales could be carried out is presented.


Assuntos
Radiobiologia/tendências , Radiometria/tendências , Humanos , Dosagem Radioterapêutica , Eficiência Biológica Relativa
9.
Perfusion ; 29(6): 517-25, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24594638

RESUMO

INTRODUCTION: Transmembrane pressure drop reflects the resistance of an artificial lung system to blood transit. Decreased resistance (low transmembrane pressure drop) enhances blood flow through the oxygenator, thereby, enhancing gas exchange efficiency. This study is part of a previous one where we observed the behaviour and the modulation of blood pressure drop during the passage of blood through artificial lung membranes. METHODS: Before and after the induction of multi-organ dysfunction, the animals were instrumented and analysed for venous-venous extracorporeal membrane oxygenation, using a pre-defined sequence of blood flows. RESULTS: Blood flow and revolutions per minute (RPM) of the centrifugal pump varied in a linear fashion. At a blood flow of 5.5 L/min, pre- and post-pump blood pressures reached -120 and 450 mmHg, respectively. Transmembrane pressures showed a significant spread, particularly at blood flows above 2 L/min; over the entire range of blood flow rates, there was a positive association of pressure drop with blood flow (0.005 mmHg/mL/minute of blood flow) and a negative association of pressure drop with temperature (-4.828 mmHg/(°Celsius). These associations were similar when blood flows of below and above 2000 mL/minute were examined. CONCLUSIONS: During its passage through the extracorporeal system, blood is exposed to pressure variations from -120 to 450 mmHg. At high blood flows (above 2 L/min), the drop in transmembrane pressure becomes unpredictable and highly variable. Over the entire range of blood flows investigated (0-5500 mL/min), the drop in transmembrane pressure was positively associated with blood flow and negatively associated with body temperature.


Assuntos
Pressão Sanguínea , Temperatura Corporal , Oxigenação por Membrana Extracorpórea , Insuficiência de Múltiplos Órgãos/fisiopatologia , Insuficiência de Múltiplos Órgãos/cirurgia , Animais , Velocidade do Fluxo Sanguíneo , Feminino , Suínos
10.
Sci Rep ; 3: 1770, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23640660

RESUMO

Biological validation of new radiotherapy modalities is essential to understand their therapeutic potential. Antiprotons have been proposed for cancer therapy due to enhanced dose deposition provided by antiproton-nucleon annihilation. We assessed cellular DNA damage and relative biological effectiveness (RBE) of a clinically relevant antiproton beam. Despite a modest LET (~19 keV/µm), antiproton spread out Bragg peak (SOBP) irradiation caused significant residual γ-H2AX foci compared to X-ray, proton and antiproton plateau irradiation. RBE of ~1.48 in the SOBP and ~1 in the plateau were measured and used for a qualitative effective dose curve comparison with proton and carbon-ions. Foci in the antiproton SOBP were larger and more structured compared to X-rays, protons and carbon-ions. This is likely due to overlapping particle tracks near the annihilation vertex, creating spatially correlated DNA lesions. No biological effects were observed at 28-42 mm away from the primary beam suggesting minimal risk from long-range secondary particles.


Assuntos
Carbono/química , Dano ao DNA , Prótons , Carbono/farmacologia , Sobrevivência Celular/efeitos da radiação , Células Cultivadas , Humanos , Íons/farmacologia , Radioterapia/métodos , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Raios X
11.
Br J Anaesth ; 106(3): 394-402, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21278154

RESUMO

BACKGROUND: The functional haemodynamic variables pulse pressure variation (PPV), stroke volume variation (SVV), and systolic pressure variation (SPV) are widely used to assess haemodynamic status. However, it is not known how these perform during acute lung injury (ALI). This study evaluated the effects of different ventilatory strategies on haemodynamic parameters in pigs with ALI during normovolaemia and hypovolaemia. METHODS: Eight anaesthetized Agroceres pigs [40 (1.9) kg] were instrumented with pulmonary artery, PiCCO, and arterial catheters and ventilated. Three ventilatory settings were randomly assigned for 10 min each: tidal volume (VT) 15 ml kg(-1) and PEEP 5 cm H(2)O, VT 8 ml kg(-1) and PEEP 13 cm H(2)O, or VT 6 ml kg(-1) and PEEP 13 cm H(2)O. Data were collected at each setting at baseline, after ALI (lung lavage+Tween 1.5%), and ALI with hypovolaemia (haemorrhage to 30% of estimated blood volume). RESULTS: At baseline, high VT increased PPV, SVV, and SPV (P<0.05 for all). During ALI, high VT significantly increased PPV and SVV [(P = 0.002 and P = 0.008) respectively.]. After ALI with hypovolaemia, ventilation at VT 6 ml kg(-1) and PEEP 13 cm H(2)O decreased the accuracy of functional haemodynamic variables to predict hypovolaemia, with the exception of PPV (area under the curve 0.875). The parameters obtained by PiCCO were less influenced by ventilatory changes. CONCLUSIONS: VT is the ventilatory parameter which influences functional haemodynamics the most. During ventilation with low VT and high PEEP, most functional variables are less able to accurately predict hypovolaemia secondary to haemorrhage, with the exception of PPV.


Assuntos
Lesão Pulmonar Aguda/fisiopatologia , Hipovolemia/fisiopatologia , Respiração com Pressão Positiva/métodos , Animais , Modelos Animais de Doenças , Hemodinâmica/fisiologia , Hemorragia/complicações , Hipovolemia/diagnóstico , Hipovolemia/etiologia , Monitorização Fisiológica/métodos , Sus scrofa , Volume de Ventilação Pulmonar/fisiologia
12.
Radiat Prot Dosimetry ; 143(2-4): 340-3, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21149324

RESUMO

Cellular response to radiation damage is made by a complex network of pathways and feedback loops whose spatiotemporal organisation is still unclear despite its decisive role in determining the fate of the damaged cell. Revealing the dynamic sequence of the repair proteins is therefore critical in understanding how the DNA repair mechanisms work. There are also still open questions regarding the possible movement of damaged chromatin domains and its role as trigger for lesion recognition and signalling in the DNA repair context. The single-cell approach and the high spatial resolution offered by microbeams provide the perfect tool to study and quantify the dynamic processes associated with the induction and repair of DNA damage. We have followed the development of radiation-induced foci for three DNA damage markers (i.e. γ-H2AX, 53BP1 and hSSB1) using normal fibroblasts (AG01522), human breast adenocarcinoma cells (MCF7) and human fibrosarcoma cells (HT1080) stably transfected with yellow fluorescent protein fusion proteins following irradiation with the QUB X-ray microbeam (carbon X-rays <2 µm spot). The size and intensity of the foci has been analysed as a function of dose and time post-irradiation to investigate the dynamics of the above-mentioned DNA repair processes and monitor the remodelling of chromatin structure that the cell undergoes to deal with DNA damage.


Assuntos
Técnicas de Cultura de Células/instrumentação , Dano ao DNA/fisiologia , Reparo do DNA/fisiologia , Reparo do DNA/efeitos da radiação , DNA/genética , DNA/efeitos da radiação , Doses de Radiação , Radiobiologia/instrumentação , DNA/química , Humanos
13.
Radiat Prot Dosimetry ; 143(2-4): 335-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21113061

RESUMO

Microbeams have undergone a renaissance since their introduction and early use in the mid-60s. Recent advances in imaging, software and beam delivery have allowed rapid technological developments in microbeams for use in a range of experimental studies. Microbeams allow the effects of single radiation tracks to be determined in a highly quantified way. They offer a unique tool for following DNA damage and repair in a highly controlled way. More importantly, they allow radiation to be targeted to specific regions within a cell to probe subcellular radiosensitivity. They are also playing an important role in our understanding of bystander responses, where cells not directly irradiated can respond to irradiated neighbours. Although these processes have been studied using a range of experimental approaches, microbeams offer a unique route by which bystander responses can be elucidated. Without exception, all of the microbeams currently active have studied bystander responses in a range of cell and tissue models. Together, these studies have considerably advanced our knowledge of the underpinning mechanisms. Much of this has come from charged particle microbeam studies, but increasingly, X-ray and electron microbeams are starting to contribute quantitative and mechanistic information on bystander effects. A recent development has been the move from studies with 2-D cell culture models to more complex 3-D systems where the possibilities of utilising the unique characteristics of microbeams in terms of their spatial and temporal delivery will make a major impact.


Assuntos
Técnicas de Cultura de Células/instrumentação , Radiobiologia/instrumentação , Radiobiologia/métodos , Irradiação Corporal Total/instrumentação , Irradiação Corporal Total/métodos , Desenho de Equipamento , Avaliação da Tecnologia Biomédica
14.
Opt Lett ; 35(18): 3105-7, 2010 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20847793

RESUMO

An optical resonator, designed for frequency doubling of cw single-frequency radiation, is simultaneously injected by two phase-coherent laser beams with the same frequency. By using standard methods in laser-cavity stabilization, we are able to stabilize the cavity length on resonance with the laser, as well as the relative phase of the fundamental beams, to fulfill the optimum coupling conditions simultaneously on the two input couplers. By using this method, we generate reliably more than 220 mW of single-frequency radiation at 399 nm using two 0.5 W semiconductor tapered amplifiers at 798 nm. This method can be generalized to a larger number of input couplers and holds promise for improving the performances of extreme-UV frequency combs.

15.
Nanotechnology ; 21(29): 295101, 2010 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-20601762

RESUMO

High atomic number (Z) materials such as gold preferentially absorb kilovoltage x-rays compared to soft tissue and may be used to achieve local dose enhancement in tumours during treatment with ionizing radiation. Gold nanoparticles have been demonstrated as radiation dose enhancing agents in vivo and in vitro. In the present study, we used multiple endpoints to characterize the cellular cytotoxic response of a range of cell lines to 1.9 nm gold particles and measured dose modifying effects following transient exposure at low concentrations. Gold nanoparticles caused significant levels of cell type specific cytotoxicity, apoptosis and increased oxidative stress. When used as dose modifying agents, dose enhancement factors varied between the cell lines investigated with the highest enhancement being 1.9 in AGO-1522B cells at a nanoparticle concentration of 100 microg ml(-1). This study shows exposure to 1.9 nm gold particles to induce a range of cell line specific responses including decreased clonogenic survival, increased apoptosis and induction of DNA damage which may be mediated through the production of reactive oxygen species. This is the first study involving 1.9 nm nanometre sized particles to report multiple cellular responses which impact on the radiation dose modifying effect. The findings highlight the need for extensive characterization of responses to gold nanoparticles when assessing dose enhancing potential in cancer therapy.


Assuntos
Ouro/farmacologia , Nanopartículas Metálicas/uso terapêutico , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Processos de Crescimento Celular/efeitos dos fármacos , Processos de Crescimento Celular/efeitos da radiação , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Quebras de DNA de Cadeia Dupla , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Citometria de Fluxo , Ouro/administração & dosagem , Ouro/farmacocinética , Humanos , Nanopartículas Metálicas/química , Dinâmica não Linear , Oxirredução , Estresse Oxidativo/efeitos dos fármacos , Estresse Oxidativo/efeitos da radiação , Radiossensibilizantes/administração & dosagem , Radiossensibilizantes/química , Radiossensibilizantes/farmacocinética
16.
Respir Med ; 104(1): 134-41, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19716690

RESUMO

BACKGROUND: Patients with idiopathic pulmonary fibrosis (IPF) present an important ventilatory limitation reducing their exercise capacity. Non-invasive ventilatory support has been shown to improve exercise capacity in patients with obstructive diseases; however, its effect on IPF patients remains unknown. OBJECTIVE: The present study assessed the effect of ventilatory support using proportional assist ventilation (PAV) on exercise capacity in patients with IPF. METHODS: Ten patients (61.2+/-9.2 year-old) were submitted to a cardiopulmonary exercise testing, plethysmography and three submaximal exercise tests (60% of maximum load): without ventilatory support, with continuous positive airway pressure (CPAP) and PAV. Submaximal tests were performed randomly and exercise capacity, cardiovascular and ventilatory response as well as breathlessness subjective perception were evaluated. Lactate plasmatic levels were obtained before and after submaximal exercise. RESULTS: Our data show that patients presented a limited exercise capacity (9.7+/-3.8 mL O(2)/kg/min). Submaximal test was increased in patients with PAV compared with CPAP and without ventilatory support (respectively, 11.1+/-8.8 min, 5.6+/-4.7 and 4.5+/-3.8 min; p<0.05). An improved arterial oxygenation and lower subjective perception to effort was also observed in patients with IPF when exercise was performed with PAV (p<0.05). IPF patients performing submaximal exercise with PAV also presented a lower heart rate during exercise, although systolic and diastolic pressures were not different among submaximal tests. Our results suggest that PAV can increase exercise tolerance and decrease dyspnoea and cardiac effort in patients with idiopathic pulmonary fibrosis.


Assuntos
Tolerância ao Exercício/fisiologia , Fibrose Pulmonar Idiopática/fisiopatologia , Ventilação Pulmonar/fisiologia , Idoso , Antropometria , Teste de Esforço , Feminino , Humanos , Fibrose Pulmonar Idiopática/reabilitação , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio
17.
Braz J Med Biol Res ; 41(8): 648-56, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18797696

RESUMO

We evaluated the recovery of cardiovascular function after transient cardiogenic shock. Cardiac tamponade was performed for 1 h and post-shock data were collected in 5 domestic large white female pigs (43 +/- 5 kg) for 6 h. The control group (N = 5) was observed for 6 h after 1 h of resting. During 1 h of cardiac tamponade, experimental animals evolved a low perfusion status with a higher lactate level (8.0 +/- 2.2 vs 1.9 +/- 0.9 mEq/L), lower standard base excess (-7.3 +/- 3.3 vs 2.0 +/- 0.9 mEq/L), lower urinary output (0.9 +/- 0.9 vs 3.0 +/- 1.4 mL x kg(-1) x h(-1)), lower mixed venous saturation, higher ileum partial pressure of CO2-end tidal CO2 (EtCO2) gap and a lower cardiac index than the control group. Throughout the 6-h recovery phase after cardiac tamponade, tamponade animals developed significant tachycardia with preserved cardiac index, resulting in a lower left ventricular stroke work, suggesting possible myocardial dysfunction. Vascular dysfunction was present with persistent systemic hypotension as well as persistent pulmonary hypertension. In contrast, oliguria, hyperlactatemia and metabolic acidosis were corrected by the 6th hour. The inflammatory characteristics were an elevated core temperature and increased plasma levels of interleukin-6 in the tamponade group compared to the control group. We conclude that cardiovascular recovery after a transient and severe low flow systemic state was incomplete. Vascular dysfunction persisted up to 6 h after release of tamponade. These inflammatory characteristics may also indicate that inflammatory activation is a possible pathway involved in the pathogenesis of cardiogenic shock.


Assuntos
Tamponamento Cardíaco/fisiopatologia , Hipotensão/fisiopatologia , Choque Cardiogênico/fisiopatologia , Síndrome de Resposta Inflamatória Sistêmica/fisiopatologia , Animais , Tamponamento Cardíaco/sangue , Feminino , Hipotensão/etiologia , Recuperação de Função Fisiológica , Choque Cardiogênico/sangue , Suínos , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Fatores de Tempo
18.
Braz. j. med. biol. res ; 41(8): 648-656, Aug. 2008. graf, tab
Artigo em Inglês | LILACS | ID: lil-491920

RESUMO

We evaluated the recovery of cardiovascular function after transient cardiogenic shock. Cardiac tamponade was performed for 1 h and post-shock data were collected in 5 domestic large white female pigs (43 ± 5 kg) for 6 h. The control group (N = 5) was observed for 6 h after 1 h of resting. During 1 h of cardiac tamponade, experimental animals evolved a low perfusion status with a higher lactate level (8.0 ± 2.2 vs 1.9 ± 0.9 mEq/L), lower standard base excess (-7.3 ± 3.3 vs 2.0 ± 0.9 mEq/L), lower urinary output (0.9 ± 0.9 vs 3.0 ± 1.4 mL·kg-1·h-1), lower mixed venous saturation, higher ileum partial pressure of CO2-end tidal CO2 (EtCO2) gap and a lower cardiac index than the control group. Throughout the 6-h recovery phase after cardiac tamponade, tamponade animals developed significant tachycardia with preserved cardiac index, resulting in a lower left ventricular stroke work, suggesting possible myocardial dysfunction. Vascular dysfunction was present with persistent systemic hypotension as well as persistent pulmonary hypertension. In contrast, oliguria, hyperlactatemia and metabolic acidosis were corrected by the 6th hour. The inflammatory characteristics were an elevated core temperature and increased plasma levels of interleukin-6 in the tamponade group compared to the control group. We conclude that cardiovascular recovery after a transient and severe low flow systemic state was incomplete. Vascular dysfunction persisted up to 6 h after release of tamponade. These inflammatory characteristics may also indicate that inflammatory activation is a possible pathway involved in the pathogenesis of cardiogenic shock.


Assuntos
Animais , Feminino , Tamponamento Cardíaco/fisiopatologia , Hipotensão/fisiopatologia , Choque Cardiogênico/fisiopatologia , Síndrome de Resposta Inflamatória Sistêmica/fisiopatologia , Tamponamento Cardíaco/sangue , Hipotensão/etiologia , Recuperação de Função Fisiológica , Suínos , Choque Cardiogênico/sangue , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Fatores de Tempo
19.
Artigo em Inglês | MEDLINE | ID: mdl-16787297

RESUMO

The mortality rate of severe sepsis is still high (20 to 65%) despite the advances in critical care. The most important determinant of the prognosis in this condition is the occurrence of multiple organ dysfunction syndrome (MODS). The lung is the most frequently identified organ to fail in sepsis and is also the most frequent primary site of infection. The development of acute respiratory distress syndrome (ARDS) is common in those cases. The current understanding of the pathogenesis of ARDS suggests that the degree of inflammatory response and its sustained leukocyte activation may determine the clinical evolution of ARDS. The way that mechanical ventilation is delivered is responsible for the start and/or the perpetuation of a pro-inflammatory cascade activation that, due to the loss of the alveolar compartmentalization in ARDS, can reach the bloodstream and induce MODS. On the other hand, during sepsis, the alveolar compartmentalization is lost, allowing the passage of cytokines, released to the bloodstream by any other organ, to the pulmonary endothelium. These cytokines, especially IL-1, TNF-alpha and IL-8, have important roles in the lung dysfunction. Experimental and clinical studies have been demonstrated that ventilation strategies using low tidal volumes and limitation of airway pressures can block cytokines and reduce mortality of patients with respiratory failure. The studies are still insufficient to determine the role of pharmacological therapies in those patients.


Assuntos
Síndrome do Desconforto Respiratório/microbiologia , Sepse/microbiologia , Animais , Humanos , Pulmão/microbiologia , Síndrome do Desconforto Respiratório/sangue , Síndrome do Desconforto Respiratório/imunologia , Sepse/sangue , Sepse/imunologia