Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38931627

RESUMO

We demonstrate substrate-emitting resonant cavity interband cascade light emitting diodes (RCICLEDs) based on a single distributed Bragg reflector (DBR). These devices operate in continuous wave mode at room temperature. Compared to standard ICLEDs without a cavity, we achieved an 89% reduction in the emission spectrum width, as indicated by the Full Width Half Maximum (FWHM) of 70 nm. Furthermore, we observed far-field narrowing and improved thermal stability. A single DBR configuration allows the cavity length to be adjusted by adding refractive index-matched material to the top of the epitaxial structure after epitaxial growth. This modification effectively shifts the cavity response towards longer wavelengths. We fabricated emitters comprising two cavities of different lengths, resulting in the emission of two distinct spectral lines that can be independently controlled. This dual-color capability enables one of the emission lines to serve as a built-in reference channel, making these LEDs highly suitable for cost-effective gas-sensing applications.

2.
Appl Spectrosc ; 77(9): 1073-1086, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37525897

RESUMO

The analytical performance of a compact infrared attenuated total reflection spectrometer using a pyroelectric detector array has been evaluated and compared to a conventional laboratory Fourier transform infrared system for applications in food analysis. Analytical characteristics including sensitivity, repeatability, linearity of the calibration functions, signal-to-noise ratio, and spectral resolution have been derived for both approaches. Representative analytes of relevance in food industries (i.e., organic solvents, fatty acids, and mycotoxins) have been used for the assessment of the performance of the device and to discuss the potential of this technology in food and feed analysis.


Assuntos
Ácidos Graxos , Análise de Alimentos , Espectroscopia de Infravermelho com Transformada de Fourier , Ácidos Graxos/análise
3.
Appl Spectrosc ; 75(3): 336-342, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33215517

RESUMO

The detection and measurement of hydrocarbons are of high interest for a variety of applications, for example within the oil and gas industry from extraction throughout the complete refining process, as well as for environmental monitoring and for portable safety devices. This paper presents a highly sensitive, selective, and robust tunable laser analyzer that has the capability to analyze several components in a gas sample stream. More specifically, a multi-gas system for simultaneous detection of C1 to iC5 hydrocarbons, using a room temperature distributed feedback interband cascade laser array, emitting in the 3.3 µm band has been realized. It combines all the advantages of the tunable laser spectroscopy method for a fast, sensitive, and selective in-line multicomponent tunable laser analyzer. Capable of continuous and milliseconds fast monitoring of C1-iC5 hydrocarbon compositions in a process stream, the analyzer requires no consumables (e.g., purging, carrier gas) and no in-field calibration, enabling a low cost of ownership for the analyzer. The system was built based on an industrial GasEye series platform and deployed for the first time in field at Preem refinery in Lysekil, Sweden, in autumn 2018. Results of the measurement campaign and comparison with gas chromatography instrumentation are presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...