1.
Radiologe ; 59(10): 860-868, 2019 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-30874826

RESUMO

BACKGROUND: Patients undergoing MRI examinations are exposed to a strong static magnetic field and powerful electromagnetic alternating fields. Undesired or even dangerous effects could be caused if implants or objects with magnetic or electrically conductive elements are accidentally brought into the examination area. METHODS: Relevant interactions in MRI between magnetic/electric fields and body tissue as well as foreign materials are systematically presented, based on proven physical principles. RESULTS OF PRACTICAL RELEVANCE: Natural components of the human body are mainly diamagnetic leading to only hardly perceptible magnetic forces in MRI. In contrast, ferromagnetic items as iron show translational forces of more than hundred times their weight force when brought to the entry of the bore. Lengthy ferromagnetic items are additionally subjected to torque. Materials with high electrical conductivity as metals and carbon fibre-reinforced plastic are also safety relevant. Especially long conductive structures as often present in implants are prone to induced strong electrical currents and high voltages at their end portions. Maximum voltages occurring at the implants and current density in adjacent tissue which might cause significant heating are hardly predictable for individual cases. Implants providing extended conductive loops for ring currents often show strong vibrations due to gradient switching. Counter forces must be considered when tilting conductive plates or ring structures inside the magnetic field area.


Assuntos
Campos Eletromagnéticos , Imageamento por Ressonância Magnética , Condutividade Elétrica , Humanos , Metais , Próteses e Implantes
2.
Magn Reson Imaging ; 53: 134-147, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30036653

RESUMO

Magnetic resonance (MR) imaging offers a wide variety of imaging techniques. A large amount of data is created per examination which needs to be checked for sufficient quality in order to derive a meaningful diagnosis. This is a manual process and therefore time- and cost-intensive. Any imaging artifacts originating from scanner hardware, signal processing or induced by the patient may reduce the image quality and complicate the diagnosis or any image post-processing. Therefore, the assessment or the ensurance of sufficient image quality in an automated manner is of high interest. Usually no reference image is available or difficult to define. Therefore, classical reference-based approaches are not applicable. Model observers mimicking the human observers (HO) can assist in this task. Thus, we propose a new machine-learning-based reference-free MR image quality assessment framework which is trained on HO-derived labels to assess MR image quality immediately after each acquisition. We include the concept of active learning and present an efficient blinded reading platform to reduce the effort in the HO labeling procedure. Derived image features and the applied classifiers (support-vector-machine, deep neural network) are investigated for a cohort of 250 patients. The MR image quality assessment framework can achieve a high test accuracy of 93.7% for estimating quality classes on a 5-point Likert-scale. The proposed MR image quality assessment framework is able to provide an accurate and efficient quality estimation which can be used as a prospective quality assurance including automatic acquisition adaptation or guided MR scanner operation, and/or as a retrospective quality assessment including support of diagnostic decisions or quality control in cohort studies.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Máquina de Vetores de Suporte , Adulto , Idoso , Bases de Dados Factuais , Aprendizado Profundo , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Variações Dependentes do Observador , Estudos Prospectivos , Curva ROC , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador
3.
Med Image Anal ; 42: 129-144, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28800546

RESUMO

PURPOSE: To develop a motion correction for Positron-Emission-Tomography (PET) using simultaneously acquired magnetic-resonance (MR) images within 90 s. METHODS: A 90 s MR acquisition allows the generation of a cardiac and respiratory motion model of the body trunk. Thereafter, further diagnostic MR sequences can be recorded during the PET examination without any limitation. To provide full PET scan time coverage, a sensor fusion approach maps external motion signals (respiratory belt, ECG-derived respiration signal) to a complete surrogate signal on which the retrospective data binning is performed. A joint Compressed Sensing reconstruction and motion estimation of the subsampled data provides motion-resolved MR images (respiratory + cardiac). A 1-POINT DIXON method is applied to these MR images to derive a motion-resolved attenuation map. The motion model and the attenuation map are fed to the Customizable and Advanced Software for Tomographic Reconstruction (CASToR) PET reconstruction system in which the motion correction is incorporated. All reconstruction steps are performed online on the scanner via Gadgetron to provide a clinically feasible setup for improved general applicability. The method was evaluated on 36 patients with suspected liver or lung metastasis in terms of lesion quantification (SUVmax, SNR, contrast), delineation (FWHM, slope steepness) and diagnostic confidence level (3-point Likert-scale). RESULTS: A motion correction could be conducted for all patients, however, only in 30 patients moving lesions could be observed. For the examined 134 malignant lesions, an average improvement in lesion quantification of 22%, delineation of 64% and diagnostic confidence level of 23% was achieved. CONCLUSION: The proposed method provides a clinically feasible setup for respiratory and cardiac motion correction of PET data by simultaneous short-term MRI. The acquisition sequence and all reconstruction steps are publicly available to foster multi-center studies and various motion correction scenarios.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Técnicas de Imagem de Sincronização Cardíaca , Humanos , Reprodutibilidade dos Testes , Técnicas de Imagem de Sincronização Respiratória , Sensibilidade e Especificidade , Razão Sinal-Ruído
4.
Sci Rep ; 7(1): 2261, 2017 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-28536464

RESUMO

Renal sinus fat (RSF) is a perivascular fat compartment located around renal arteries. In this in vitro and in vivo study we hypothesized that the hepatokine fetuin-A may impair renal function in non alcoholic fatty liver disease (NAFLD) by altering inflammatory signalling in RSF. To study effects of the crosstalk between fetuin-A, RSF and kidney, human renal sinus fat cells (RSFC) were isolated and cocultured with human endothelial cells (EC) or podocytes (PO). RSFC caused downregulation of proinflammatory and upregulation of regenerative factors in cocultured EC and PO, indicating a protective influence of RFSC. However, fetuin-A inverted these benign effects of RSFC from an anti- to a proinflammatory status. RSF was quantified by magnetic resonance imaging and liver fat content by 1H-MR spectroscopy in 449 individuals at risk for type 2 diabetes. Impaired renal function was determined via urinary albumin/creatinine-ratio (uACR). RSF did not correlate with uACR in subjects without NAFLD (n = 212, p = 0.94), but correlated positively in subjects with NAFLD (n = 105, p = 0.0005). Estimated glomerular filtration rate (eGRF) was inversely correlated with RSF, suggesting lower eGFR for subjects with higher RSF (r = 0.24, p < 0.0001). In conclusion, our data suggest that in the presence of NAFLD elevated fetuin-A levels may impair renal function by RSF-induced proinflammatory signalling in glomerular cells.


Assuntos
Gordura Intra-Abdominal/fisiologia , Glomérulos Renais/citologia , Glomérulos Renais/metabolismo , Rim/anatomia & histologia , Rim/fisiologia , Artéria Renal/anatomia & histologia , alfa-2-Glicoproteína-HS/metabolismo , Adipócitos/metabolismo , Adulto , Células Cultivadas , Técnicas de Cocultura , Citocinas/metabolismo , Feminino , Expressão Gênica , Humanos , Imuno-Histoquímica , Mediadores da Inflamação/metabolismo , Gordura Intra-Abdominal/diagnóstico por imagem , Rim/diagnóstico por imagem , Macrófagos/metabolismo , Masculino , Pessoa de Meia-Idade , RNA Mensageiro/genética , Artéria Renal/diagnóstico por imagem
5.
Diabetes Metab ; 43(3): 229-239, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28089502

RESUMO

BACKGROUND: In clinical practice, there is a strong interest in non-invasive markers of non-alcoholic fatty liver disease (NAFLD). Our hypothesis was that the fold-change in plasma triglycerides (TG) during a 2-h oral glucose tolerance test (fold-change TGOGTT) in concert with blood glucose and lipid parameters, and the rs738409 C>G single nucleotide polymorphism (SNP) in PNPLA3 might improve the power of the widely used fatty liver index (FLI) to predict NAFLD. METHODS: The liver fat content of 330 subjects was quantified by 1H-magnetic resonance spectroscopy. Blood parameters were measured during fasting and after a 2-h OGTT. A subgroup of 213 subjects underwent these measurements before and after 9 months of a lifestyle intervention. RESULTS: The fold-change TGOGTT was closely associated with liver fat content (r=0.51, P<0.0001), but had less power to predict NAFLD (AUROC=0.75) than the FLI (AUROC=0.79). Not only was the fold-change TGOGTT independently associated with liver fat content and NAFLD, but so also were the 2-h blood glucose level and rs738409 C>G SNP in PNPLA3. In fact, a novel index (extended FLI) generated from these and the usual FLI parameters considerably increased its power to predict NAFLD (AUROC=0.79-0.86). The extended FLI also increased the power to predict changes in liver fat content with a lifestyle intervention (n=213; standardized beta coefficient: 0.23-0.29). CONCLUSION: This study has provided novel data confirming that the OGTT-derived fold-change TGOGTT and 2-h glucose level, together with the rs738409 C>G SNP in PNPLA3, allow calculation of an extended FLI that considerably improves its power to predict NAFLD.


Assuntos
Hepatopatia Gordurosa não Alcoólica/diagnóstico , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Adulto , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/sangue , Hepatopatia Gordurosa não Alcoólica/fisiopatologia , Valor Preditivo dos Testes , Curva ROC , Triglicerídeos/sangue
6.
Clin Physiol Funct Imaging ; 37(6): 558-566, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26865009

RESUMO

This report provides an overview on the present knowledge on intramyocellular lipids (IMCL) and their dynamics in the course of interventions with physical activity of variable type and intensity in different population groups, as accessible by examinations using non-invasive volume-selective 1 H magnetic resonance spectroscopy (1 H MRS). IMCL serve as energy source in skeletal muscle for fat oxidation in the mitochondria and became intensively studied after discovery of their relation with insulin sensitivity. While baseline levels of IMCL concentration have been shown to be mainly dependent on the metabolic status (insulin sensitivity), on the level of training and on fibre composition in the muscles, studies applying different physical activity protocols revealed the dynamic of their depletion and replenishment. From the findings in human studies, it can be concluded that IMCL levels are potentially useful markers for monitoring metabolic adaptation of skeletal muscle to sportive activities and training.


Assuntos
Metabolismo Energético , Gotículas Lipídicas/metabolismo , Metabolismo dos Lipídeos , Contração Muscular , Músculo Esquelético/metabolismo , Espectroscopia de Prótons por Ressonância Magnética , Adaptação Fisiológica , Humanos , Resistência à Insulina , Cinética , Estado Nutricional , Oxirredução , Valor Preditivo dos Testes
7.
IEEE Trans Med Imaging ; 35(11): 2447-2458, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27295659

RESUMO

A Cartesian subsampling scheme is proposed incorporating the idea of PF acquisition and variable-density Poisson Disc (vdPD) subsampling by redistributing the sampling space onto a smaller region aiming to increase k-space sampling density for a given acceleration factor. Especially the normally sparse sampled high-frequency components benefit from this sampling redistribution, leading to improved edge delineation. The prospective subsampled and compacted k-space can be reconstructed by a seamless combination of a CS-algorithm with a Hermitian symmetry constraint accounting for the missing part of the k-space. This subsampling and reconstruction scheme is called Compressed Sensing Partial Subsampling (ESPReSSo) and was tested on in-vivo abdominal MRI datasets. Different reconstruction methods and regularizations are investigated and analyzed via global (intensity-based) and local (region-of-interest and line evaluation) image metrics, to conclude a clinical feasible setup. Results substantiate that ESPReSSo can provide improved edge delineation and regional homogeneity for multidimensional and multi-coil MRI datasets and is therefore useful in applications depending on well-defined tissue boundaries, such as image registration and segmentation or detection of small lesions in clinical diagnostics.


Assuntos
Análise de Fourier , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Abdome/diagnóstico por imagem , Adulto , Algoritmos , Feminino , Humanos , Masculino , Adulto Jovem
8.
Scand J Med Sci Sports ; 26(10): 1200-8, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26369754

RESUMO

The purpose of this study was to evaluate temporal alterations of the Achilles tendon volume and hydration state after cross-country-running. Achilles tendons of six untrained participants were examined on a 3T MR-scanner before running, immediately afterwards, and in the following 24, 48, and 72 h. Using a 3D-UTE sequence, caudal (CA) and cranial (CR) mid-portion tendon areas were examined with off-resonance saturation ratios (OSR) and T2* relaxation times. Tendon volume was measured with a self-written Matlab-based automated contour detection algorithm (AVAT) in submillimeter T2-weighted MR images. A significant influence of running in caudal (P = 0.017) and cranial OSR values (P = 0.001), tendon volume (P = 0.024), and cranial T2* measurements (P = 0.046), but not in caudal T2* values (P = 0.298) were found. In detail, mean individual OSR and tendon volume measurements demonstrated a similar but inverted course in their values after exercise: initially, OSR values increased after running (and tendon volume decreased), while subsequently a decrease of OSR values (with an increase of tendon volume) could be observed. OSR and tendon volume measurements are able to detect a physiological response of tendons to a mechanical stimulus. After a transient decrease of free water in the Achilles tendon, an increase with a maximum free water content 48 h after ankle loading and a tendency toward normalization after 72 h was found.


Assuntos
Tendão do Calcâneo/anatomia & histologia , Tendão do Calcâneo/metabolismo , Articulação do Tornozelo/fisiologia , Imageamento por Ressonância Magnética , Corrida/fisiologia , Suporte de Carga/fisiologia , Tendão do Calcâneo/diagnóstico por imagem , Adulto , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Tamanho do Órgão , Fatores de Tempo , Água/metabolismo
9.
Rofo ; 187(11): 1003-10, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26090729

RESUMO

PURPOSE: The purpose of this study was to evaluate whether gravitational interstitial fluid accumulation in healthy subjects has an impact on off-resonance saturation ratios (OSR) or the volume of the Achilles tendon after a prolonged time of reduced levels of physical activity. MATERIALS AND METHODS: 7 healthy volunteers were repeatedly investigated on 3 consecutive days on a 3 T whole body MR scanner using an ultrashort echo time (UTE) imaging sequence with a Gaussian off-resonance saturation pulse at a frequency offset of 2000 Hz to calculate OSR values. For accurate volumetric quantification of the Achilles tendon, a newly developed contour detection snake algorithm was applied on high-resolution isotropic T2-weighted SPACE sequence datasets. Single-measure intraclass correlation coefficients (ICC) were calculated to estimate test-retest reliability. RESULTS: For OSR and tendon volume measurements on three consecutive days, excellent reproducibility could be achieved with ICC values above 0.96 and 0.97, respectively. Comparing the results of all three days, a statistically significant mean individual percentage decrease (- 4.1  ±â€Š1.5 %; p = 0.001) of calculated tendon OSR values was found for the evening measurements. No statistically significant difference between tendon volumes in the morning and the evening could be detected (p = 0.589). CONCLUSION: The results of this in-vivo study demonstrate a significant influence of gravitational interstitial fluid accumulation after reduced physical activity on OSR values in the Achilles tendon, but not on tendon volume. Taken together with the demonstrated excellent reproducibility, these findings are important for future studies investigating temporal changes of the Achilles tendon microstructure.


Assuntos
Tendão do Calcâneo/anatomia & histologia , Ritmo Circadiano/fisiologia , Líquido Extracelular/fisiologia , Deslocamentos de Líquidos Corporais/fisiologia , Gravitação , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Adulto , Feminino , Humanos , Masculino , Atividade Motora/fisiologia , Distribuição Normal , Tamanho do Órgão/fisiologia , Valores de Referência
10.
Radiologe ; 55(4): 323-8, 2015 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-25784131

RESUMO

OBJECTIVES: The aim of this study was to investigate potential associations between changes in liver volume, the amount of intrahepatic lipids (IHL) and body weight during lifestyle interventions. MATERIAL AND METHODS: In a prospective study 150 patients with an increased risk for developing type 2 diabetes mellitus were included who followed a caloric restriction diet for 6 months. In the retrospective analysis 18 women and 9 men (age range 22-71 years) with an average body mass index (BMI) of 32 kg/m(2) were enrolled. The liver volume was determined at the beginning and after 6 months by three-dimensional magnetic resonance imaging (3D-MRI, echo gradient, opposed-phase) and IHLs were quantified by volume-selective MR spectroscopy in single voxel stimulated echo acquisition mode (STEAM). Univariable and multivariable correlation analyses between changes of liver volume (Δliver volume), intrahepatic lipids (ΔIHL) and body weight (ΔBW) were performed. RESULTS: Univariable correlation analysis in the whole study cohort showed associations between ΔIHL and ΔBW (r = 0.69; p < 0.0001), ΔIHL and Δliver volume (r = 0.66; p = 0.0002) as well as ΔBW and Δliver volume (r = 0.5; p = 0.0073). Multivariable correlation analysis revealed that changes of liver volume are primarily determined by changes in IHL independent of changes in body weight (ß = 0.0272; 95% CI: 0.0155-0.034; p < 0.0001). CONCLUSION: Changes of liver volume during lifestyle interventions are independent of changes of body weight primarily determined by changes of IHL. These results show the reversibility of augmented liver volume in steatosis if it is possible to reduce IHLs during lifestyle interventions.


Assuntos
Peso Corporal , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/prevenção & controle , Gordura Intra-Abdominal/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Diabetes Mellitus Tipo 2/fisiopatologia , Humanos , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Comportamento de Redução do Risco , Sensibilidade e Especificidade , Resultado do Tratamento
11.
Br J Radiol ; 87(1044): 20140426, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25270833

RESUMO

OBJECTIVE: The aim of this study was to evaluate combined two-dimensional (2D) and three-dimensional (3D) dynamic MR urography with respiratory compensation in children with anomalies of the genitourinary tract, allowing for computation of split renal function and assessment of urinary tract obstruction. METHODS: Dynamic MR urography was performed in 53 children (3 months-16 years of age) with anomalies of the urinary tract. A protocol for dynamic MR urography and nephrography was implemented at 1.5 T using a navigator-triggered 2D TurboFLASH sequence. Split renal function and contrast-medium excretion were assessed after the bolus injection of 0.05 mmol kg(-1) body weight of gadolinium dimeglumine. In the excretory phase, a 3D gradient-echo data set with high spatial resolution was acquired. In all patients, mercaptoacetyltriglycine (MAG3) scintigraphy was obtained as a reference standard. RESULTS: In all children, dynamic MR nephrography and urography could be performed with excellent compensation of breathing artefacts providing region of interest analysis in nearly identical kidney positions. The assessment of contrast-medium excretion into the ureter allowed for discrimination of functional from non-functional stenosis. Split renal function assessed by MRI showed an excellent agreement with the MAG3 reference standard with a correlation coefficient r = 0.95. Additionally recorded 3D data sets offered good depiction of anatomical anomalies in all patients. CONCLUSION: The proposed protocol provides a robust technique for assessment of ureteral obstruction and split renal function with compensation of breathing artefacts, short post-processing time and excellent 3D spatial resolution. ADVANCES IN KNOWLEDGE: The combined protocol of 2D and 3D MR urography is an efficient technique for assessment of renal morphology and function.


Assuntos
Gadolínio DTPA , Glicina/análogos & derivados , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Urografia/métodos , Doenças Urológicas/diagnóstico , Adolescente , Artefatos , Criança , Pré-Escolar , Meios de Contraste , Feminino , Seguimentos , Humanos , Lactente , Masculino , Reprodutibilidade dos Testes
12.
Arch Orthop Trauma Surg ; 134(10): 1443-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25052771

RESUMO

INTRODUCTION: Assessment of the Achilles tendon thickness (ATT) using B-mode ultrasound is a common technique for clinical evaluation of chronic mid-part tendinosis. Currently used image-based assessment is limited by relatively high inter- and intra-observer variability. In this study, it was tested whether a new sequence-based automated assessment of ATT provides more reliable and reproducible results than the standard image-based procedure. MATERIALS AND METHODS: A total of 118 non-operated tendons of 59 healthy subjects (44, range 28-50 years) were analysed using an automated image based as well as a newly developed automated sequence-based method. Correlation and agreement of both methods were evaluated. The root mean square deviation (RMSD) and a Bland-Altman analysis were performed to highlight observer (n = 18 tendons) as well as reader (n = 40 tendons) dependent variabilities of both methods. RESULTS: A strong correlation was found between image and sequence-based ATT assessment (p = 0.92). The Bland-Altman analysis showed a good agreement between both methods (mean difference 0.0018, 95 % CI: -0.046; 0.05). In repetitive examinations, sequence-based analysis showed a significant reduction concerning reader- and observer-dependent variability compared to image-based assessment. The RMSD for repetitive sequence-based measurements was approximately 0.3 mm (compared to 0.6 mm for image-based measurement), respectively. CONCLUSIONS: The study shows sequence-based automated assessment of ATT being clearly superior to the standard image-based procedure. The new method provides a clear reduction of reader as well as observer-dependent variability. Due to the decreased scattering of measurement data sequence-based measurement seems especially valuable for quantification of small tendon thickness changes such as exercise-induced hypertrophy.


Assuntos
Tendão do Calcâneo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Tendão do Calcâneo/anatomia & histologia , Adulto , Algoritmos , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Ultrassonografia
13.
Radiologe ; 53(8): 709-21; quiz 722, 2013 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-23949439

RESUMO

The second part of this educational article focuses on sequence techniques in magnetic resonance imaging (MRI) and on suitable parameter sets for different contrast weightings. The content is based on the recently published part 1 of this educational article providing a survey on tissue properties relevant for most important contrast mechanisms. Characteristics of contrast weightings are presented in exemplary images recorded from healthy volunteers. Typical clinical applications of the most commonly used contrast weightings are described and discussed. Sequences for the following contrast weightings are included: proton density (density of hydrogen in small mobile molecules), relaxation times T1 and T2, chemical shift (water and fat), effects of magnetic susceptibility, restricted diffusion of water molecules and magnetization transfer between macromolecules and water molecules.


Assuntos
Algoritmos , Meios de Contraste , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Rofo ; 185(11): 1041-55, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23888478

RESUMO

In the past decades the incidence of acute and chronic disorders of the Achilles tendon associated with sport-induced overuse has steadily increased. Besides acute complete or partial ruptures, achillodynia (Achilles tendon pain syndrome), which is often associated with tendon degeneration, represents the most challenging entity regarding clinical diagnostics and therapy. Therefore, the use of imaging techniques to differentiate tendon disorders and even characterize structure alterations is of growing interest. This review article discusses the potential of different imaging techniques with respect to the diagnosis of acute and chronic tendon disorders. In this context, the most commonly used imaging techniques are magnetic resonance imaging (MRI), B-mode ultrasound, and color-coded Doppler ultrasound (US). These modalities allow the detection of acute tendon ruptures and advanced chronic tendon disorders. However, the main disadvantages are still the low capabilities in the detection of early-stage degeneration and difficulties in the assessment of treatment responses during follow-up examinations. Furthermore, differentiation between chronic partial ruptures and degeneration remains challenging. The automatic contour detection and texture analysis may allow a more objective and quantitative interpretation, which might be helpful in the monitoring of tendon diseases during follow-up examinations. Other techniques to quantify tendon-specific MR properties, e. g. based on ultrashort echo time (UTE) sequences, also seem to have great potential with respect to the precise detection of degenerative tendon disorders and their differentiation at a very early stage.


Assuntos
Tendão do Calcâneo/lesões , Tendão do Calcâneo/patologia , Transtornos Traumáticos Cumulativos/patologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Traumatismos dos Tendões/patologia , Doença Aguda , Doença Crônica , Humanos , Ruptura/patologia
15.
Radiologe ; 53(5): 441-53;quiz 454-6, 2013 May.
Artigo em Alemão | MEDLINE | ID: mdl-23680825

RESUMO

In comparison to roentgen-based radiological examination techniques, magnetic resonance imaging (MRI) provides a wide variety of tissue contrast. This can be utilized for better detection and characterization of pathological findings. The basis of image contrast in MRI is the chemical and physical properties of the hydrogen atoms in tissue, in particular in their chemical bonds in water and lipid molecules and in the environment in which the hydrogen-containing molecules are contained. This environment is mainly determined by the composition of substances, viscosity and temperature as well as the microscopic geometrical conditions in tissue. Part 1 of this advanced education article describes those contrast mechanisms which are most commonly utilized in static clinical standard examinations of various organ systems.


Assuntos
Meios de Contraste/química , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Humanos
16.
Eur Radiol ; 23(2): 588-95, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22898936

RESUMO

OBJECTIVES: To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. METHODS: Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. RESULTS: Nitinol stents showed significantly better performance than the cobalt chromium stent (P < 0.05) at 1.5 and 3 T. Maximum visible stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". CONCLUSIONS: Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.


Assuntos
Ligas , Cobalto , Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Stents , Meios de Contraste , Feminino , Artéria Femoral , Humanos , Técnicas In Vitro , Masculino , Teste de Materiais , Imagens de Fantasmas , Desenho de Prótese , Estatísticas não Paramétricas
17.
Rofo ; 184(12): 1138-43, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23059699

RESUMO

PURPOSE: Though increased thyroid perfusion assessed by colour-coded Doppler ultrasound (CDUS) is characteristic of Graves' disease (GD), sometimes perfusion assessment by CDUS is not possible. In these cases, arterial spin labelling (ASL), a novel magnetic resonance imaging (MRI) technique allowing non-invasive thyroid perfusion quantification, may have additional diagnostic value. We aimed to evaluate the potential of ASL-MRI for assessment of increased blood perfusion in patients with GD compared to CDUS. MATERIALS AND METHODS: Thyroid perfusion was measured by CDUS (volume flow rate calculated from pulsed wave Doppler signals and vessel diameter) and ASL-MRI at 1.5 T in 7 patients with GD and 10 healthy controls. RESULTS: In patients with GD, average perfusion in both thyroid lobes was markedly increased compared to controls. Both techniques applied for volume related perfusion as well as absolute volume flow in thyroid feeding vessels provided similar results (all p=0.0008). Using a cut-off value of 22 ml/min for the volume flow rate assessed by CDUS in the four feeding vessels allowed discrimination between patients with GD and controls in all cases. After adjusting thyroid perfusion for the differences in organ volume, both CDUS and ASL revealed also complete discrimination between health and disease. CONCLUSION: Thyroid perfusion measurement by ASL-MRI reliably discriminate GD from normal thyroid glands. In patients in whom thyroid arteries cannot be depicted by CDUS for technical or anatomical reasons, ASL-MRI may have additional diagnostic value.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Doença de Graves/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Glândula Tireoide/irrigação sanguínea , Ultrassonografia Doppler em Cores/métodos , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Diagnóstico Diferencial , Feminino , Humanos , Imunoglobulinas Estimuladoras da Glândula Tireoide/sangue , Masculino , Pessoa de Meia-Idade , Valores de Referência , Sensibilidade e Especificidade , Testes de Função Tireóidea , Ultrassonografia Doppler de Pulso/métodos , Adulto Jovem
18.
Diabetologia ; 55(7): 2054-8, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22526613

RESUMO

AIMS/HYPOTHESIS: Microalbuminuria represents an established surrogate marker of early diabetic nephropathy and glomerular microangiopathy. Increasing evidence is emerging of a role of perivascular adipose tissue (PVAT) as an important link between obesity, insulin resistance and both macro- and microangiopathy. It is not known whether perivascular renal sinus fat (RSF) has an impact on microalbuminuria in the prediabetic stage. We investigated whether RSF quantified by MRI is associated with microalbuminuria before or after exercise. METHODS: Non-diabetic individuals at increased risk of type 2 diabetes were recruited into the Tübingen Lifestyle Intervention Program (TULIP); 146 participants took part in the analysis. RSF was measured in axial MRI sections at the level of the renal artery. Urine was collected before and after exercise stress testing. RESULTS: Participants (age 47 ± 12 years; mean ± SD) reached a mean exercise load of 176 ± 49 W, with a mean arterial peak pressure (MAPP) of 112 ± 14 mmHg. After adjusting for sex, age, visceral adipose tissue (VAT) and MAPP during exercise, RSF was significantly associated with postexercise albumin/creatinine ratio (ACR; p = 0.006). No association between RSF and baseline BP could be observed after adjusting for confounders (p = 0.26), and there was no association between RSF and baseline ACR either (p = 0.2). CONCLUSIONS: RSF is associated with exercise-induced albuminuria independently of sex, age, VAT and MAPP in a non-diabetic cohort at diabetic risk. We conclude that PVAT in the renal sinus may play a role in the pathogenesis of microalbuminuria.


Assuntos
Albuminúria/urina , Glicemia/metabolismo , Creatinina/urina , Diabetes Mellitus Tipo 2/complicações , Nefropatias Diabéticas/urina , Exercício Físico , Nefropatias/urina , Albuminúria/etiologia , Albuminúria/fisiopatologia , Pressão Sanguínea , Diabetes Mellitus Tipo 2/urina , Nefropatias Diabéticas/etiologia , Nefropatias Diabéticas/fisiopatologia , Teste de Esforço , Feminino , Humanos , Gordura Intra-Abdominal/metabolismo , Nefropatias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
19.
Diabetologia ; 55(6): 1660-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22349074

RESUMO

AIMS/HYPOTHESIS: The aim of this study was to compare estimates of body fat content, i.e. body adiposity index (BAI), BMI and waist and hip circumferences, with respect to their ability to predict the percentage of body fat (PBF; confirmed by magnetic resonance tomography) and incident type 2 diabetes. METHODS: Associations between anthropometric measurements and PBF were evaluated in the Tübingen Lifestyle Intervention Program (TULIP; 138 men, 222 women), and between these measurements and incident type 2 diabetes in the European Prospective Investigation into Cancer and Nutrition (EPIC)-Potsdam study (9,729 men, 15,438 women) and the Cooperative Health Research in the Region of Augsburg (KORA) study (5,573 men, 5,628 women), using correlation and multivariate Cox regression analyses. RESULTS: BMI more strongly correlated with PBF (men: r = 0.81, women: r = 0.84) than BAI (r = 0.68 and 0.81, respectively), while waist circumference among men (r = 0.84) and hip circumference among women (r = 0.88) showed the strongest correlations. BAI overestimated PBF among men (mean difference -3.0%), and this error was dependent on the value of PBF. BAI was more weakly associated with diabetes risk (RRs for 1 SD, EPIC-Potsdam men: 1.62 [95% CI 1.52, 1.72], women: 1.67 [95% CI 1.55, 1.80]; KORA men: 1.62 [95% CI 1.48, 1.78], women: 1.82 [95% CI 1.65, 2.02]) compared with BMI (RRs, EPIC-Potsdam men: 1.95 [95% CI 1.83, 2.09], women 1.88 [95% CI 1.76, 2.02], KORA men 1.75 [95% CI 1.62, 1.89], women 2.00 [95% CI 1.81, 2.22]), while waist circumference showed the strongest associations (RRs: 2.17 [95% CI 2.01, 2.35], 2.33 [95% CI 2.15, 2.53], 1.81 [95% CI 1.66, 1.96] and 2.29 [95% CI 2.05, 2.57] for EPIC-Potsdam men and women and KORA men and women, respectively). CONCLUSIONS/INTERPRETATION: Waist circumference in men and hip circumference in women are better predictors of PBF than BAI and BMI. BAI was not as strong a predictor of diabetes as BMI, while waist circumference was the strongest predictor.


Assuntos
Tecido Adiposo/metabolismo , Adiposidade/fisiologia , Diabetes Mellitus Tipo 2/epidemiologia , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Circunferência da Cintura/fisiologia
20.
Rofo ; 184(4): 324-32, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22322443

RESUMO

PURPOSE: The purpose of this study is to establish and validate a magnetic resonance (MR)-based fat quantification package that provides an accurate assessment of abdominal adipose tissue and liver fat in children. MATERIALS AND METHODS: Ex vivo trials with a torso model and water-oil mixtures are conducted. Abdominal adipose tissue (AAT) is covered by magnetic resonance imaging (MRI) using a fat-selective sequence and is analyzed by a plug-in based on the open source software ImageJ. Liver fat (LF) is measured with localized 1H Magnetic Resonance Spectroscopy (1H MRS) and the jMRUI (java-based Magnetic Resonance User Interface) software package. Evaluation of the clinical methodology involved a study of 10 children in this feasibility study (mean age and body mass index: 13.3 yr; 33.3 kg/m²). To evaluate the method's validity, reference measurements were performed. RESULTS: Ex vivo trials with the torso model showed that adipose tissue was measured appropriately with a systematic underestimation by 9.3 ± 0.2 % (0.32 ± 0.064 kg). Coefficients of variation for both intra- and inter-observer measurements ranged between 0 - 2.7 % and repeated analyses showed significant equivalent results (p < 0.01). The lipid content obtained by 1H MRS ex vivo revealed significant equivalence with the predefined fat content in water-oil mixtures (p < 0.01). In vivo, the homemade plug-in significantly overestimated the AAT, with the visceral adipose tissue being most affected (+ 15.7 ± 8.4 %). CONCLUSION: Although an overestimation of the AAT by the presented plug-in should be taken into consideration, this children-friendly package enables the quantification of both LF and AAT within 30 min on a freeware-based platform.


Assuntos
Fígado Gorduroso/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Obesidade Abdominal/diagnóstico , Software , Gordura Abdominal/patologia , Adolescente , Algoritmos , Índice de Massa Corporal , Criança , Feminino , Humanos , Fígado/patologia , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS