1.
J Microsc ; 246(2): 160-7, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22429382

RESUMO

Due to photobleaching and phototoxicity induced by high-intensity excitation light, the number of fluorescence images that can be obtained in live cells is always limited. This limitation becomes particularly prominent in multidimensional recordings when multiple Z-planes are captured at every time point. Here we present a simple technique, termed predictive-focus illumination (PFI), which helps to minimize cells' exposure to light by decreasing the number of Z-planes that need to be captured in live-cell 3D time-lapse recordings. PFI utilizes computer tracking to predict positions of objects of interest (OOIs) and restricts image acquisition to small dynamic Z-regions centred on each OOI. Importantly, PFI does not require hardware modifications and it can be easily implemented on standard wide-field and spinning-disc confocal microscopes.


Assuntos
Luz , Microscopia de Fluorescência/métodos , Fotodegradação/efeitos da radiação , Epitélio Pigmentado da Retina/citologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Epitélio Pigmentado da Retina/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...