Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Oncol ; 19(1): 80, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38918828

RESUMO

INTRODUCTION: Magnetic resonance guided radiotherapy (MRgRT) allows daily adaptation of treatment plans to compensate for positional changes of target volumes and organs at risk (OARs). However, current adaptation times are relatively long and organ movement occurring during the adaptation process might offset the benefit gained by adaptation. The aim of this study was to evaluate the dosimetric impact of these intrafractional changes. Additionally, a method to predict the extent of organ movement before the first treatment was evaluated in order to have the possibility to compensate for them, for example by adding additional margins to OARs. MATERIALS & METHODS: Twenty patients receiving adaptive MRgRT for treatment of abdominal lesions were retrospectively analyzed. Magnetic resonance (MR) images acquired at the start of adaptation and immediately before irradiation were used to calculate adapted and pre-irradiation dose in OARs directly next to the planning target volume. The extent of organ movement was determined on MR images acquired during simulation sessions and adaptive treatments, and their agreement was evaluated. Correlation between the magnitude of organ movement during simulation and the duration of simulation session was analyzed in order to assess whether organ movement might be relevant even if the adaptation process could be accelerated in the future. RESULTS: A significant increase in dose constraint violations was observed from adapted (6.9%) to pre-irradiation (30.2%) dose distributions. Overall, OAR dose increased significantly by 4.3% due to intrafractional organ movement. Median changes in organ position of 7.5 mm (range 1.5-10.5 mm) were detected within a median time of 17.1 min (range 1.6-28.7 min). Good agreement was found between the range of organ movement during simulation and adaptation (66.8%), especially if simulation sessions were longer and multiple MR images were acquired. No correlation was determined between duration of simulation sessions and magnitude of organ movement. CONCLUSION: Intrafractional organ movement can impact dose distributions and lead to violations of OAR tolerance doses, which impairs the benefit of daily on-table plan adaptation. By application of simulation images, the extent of intrafractional organ movement can be predicted, which possibly allows to compensate for them.


Assuntos
Imageamento por Ressonância Magnética , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Humanos , Radioterapia Guiada por Imagem/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Órgãos em Risco/efeitos da radiação , Imageamento por Ressonância Magnética/métodos , Neoplasias Abdominais/radioterapia , Neoplasias Abdominais/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Radioterapia de Intensidade Modulada/métodos , Movimento , Fracionamento da Dose de Radiação
2.
Cancers (Basel) ; 16(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38927978

RESUMO

(1) Background: Recent publications foster stereotactic body radiotherapy (SBRT) in patients with adrenal oligometastases or oligoprogression. However, local control (LC) after non-adaptive SBRT shows the potential for improvement. Online adaptive MR-guided SBRT (MRgSBRT) improves tumor coverage and organ-at-risk (OAR) sparing. Long-term results of adaptive MRgSBRT are still sparse. (2) Methods: Adaptive MRgSBRT was performed on a 0.35 T MR-Linac. LC, overall survival (OS), progression-free survival (PFS), overall response rate (ORR), and toxicity were assessed. (3) Results: 35 patients with 40 adrenal metastases were analyzed. The median gross tumor volume was 30.6 cc. The most common regimen was 10 fractions at 5 Gy. The median biologically effective dose (BED10) was 75.0 Gy. Plan adaptation was performed in 98% of all fractions. The median follow-up was 7.9 months. One local failure occurred after 16.6 months, resulting in estimated LC rates of 100% at one year and 90% at two years. ORR was 67.5%. The median OS was 22.4 months, and the median PFS was 5.1 months. No toxicity > CTCAE grade 2 occurred. (4) Conclusions: LC and ORR after adrenal adaptive MRgSBRT were excellent, even in a cohort with comparably large metastases. A BED10 of 75 Gy seems sufficient for improved LC in comparison to non-adaptive SBRT.

3.
Phys Imaging Radiat Oncol ; 27: 100477, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37635846

RESUMO

Background and Purpose: In online adaptive stereotactic body radiotherapy treatments, linear accelerator delivery accuracy is essential. Recently introduced double stack multileaf collimators (MLCs) have new facets in their calibration. We established a radiation-based leaf-individual calibration (LIMCA) method for double stack MLCs. Materials and Methods: MLC leaf positions were evaluated from four cardinal angles with test patterns at measurement positions throughout the radiation field on EBT3 radiochromic film for each single stack. The accuracy of the method and repeatability of the results were assessed. The effect of MLC positioning errors was characterized for a measured output factor curve and a clinical patient plan. Results: All positions in the motor step - position calibration file were optimized in the established LIMCA method. The resulting double stack mean accuracy for all angles was 0.2 ± 0.1 mm for X1 (left bank) and 0.2 ± 0.2 mm for X2 (right bank). The accuracy of the leaf position evaluation was 0.2 mm (95% confidence level). The MLC calibration remained stable over four months. Small MLC leaf position errors (e.g. 1.2 mm field size reduction) resulted in important dose errors (-5.8 %) for small quadratic fields of 0.83 × 0.83 cm2. Single stack position accuracy was essential for highly modulated treatment plans. Conclusions: LIMCA is a new double stack MLC calibration method that increases treatment accuracy from four angles and for all moving leaves.

4.
Clin Transl Radiat Oncol ; 39: 100567, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36935853

RESUMO

Purpose/Objective: To evaluate the potential of stereotactic magnetic resonance-guided online adaptive radiotherapy (SMART) to fulfill dose recommendations for stereotactic body radiotherapy (SBRT) of adrenal metastases and spare organs at risk (OAR). Materials and methods: In this subgroup analysis of a prospective registry trial, 22 patients with adrenal metastases were treated on a 0.35 T MR-Linac in 5-12 fractions with fraction doses of 4-10 Gy. Baseline plans were re-calculated to the anatomy of the day. These predicted plans were reoptimized to generate adapted plans. Baseline, predicted and adapted plans were compared with regard to PTV objectives, OAR constraints and published dose recommendations. Results: The cohort comprised patients with large GTV (median 36.0 cc) and PTV (median 66.6 cc) and predominantly left-sided metastases. 179 of 181 fractions (98.9 %) were adapted because of PTV and/or OAR violations. Predicted plans frequently violated PTV coverage (99.4 %) and adjacent OAR constraints (bowel: 32.9 %, stomach: 32.8 %, duodenum: 10.4 %, kidneys: 10.8 %). In the predicted plans, the volume exposed to the maximum dose was exceeded up to 16-fold in the duodenum and up to 96-fold in the spinal cord. Adapted plans significantly reduced OAR violations by 96.4 % for the bowel, 98.5 % for the stomach, 85.6 % for the duodenum and 83.3 % for the kidneys. Plan adaptation improved PTV coverage from 82.7 ± 8.1 % to 90.6 ± 4.9 % (p < 0.001). Furthermore, recently established target volume thresholds could easily be fulfilled with SMART. No toxicities > grade II occurred. Conclusion: SMART fulfills established GTV and PTV dose recommendations while simultaneously sparing organs at risk even in a challenging cohort.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...