1.
J Orthop Res ; 41(7): 1505-1516, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36370140

RESUMO

Three-dimensional (3D) printing is used to manufacture custom acetabular cups to treat patients with massive acetabular defects. There is a risk of defects occurring in these, often in the form of structural voids. Our aim was to investigate the presence of voids in commercially available cups. We examined 12, final-production titanium custom acetabular cups, that had been 3D-printed by six manufacturers. We measured their mass, then performed micro-computed tomography (micro-CT) imaging to determine their volume and density. The micro-CT data were examined for the presence of voids. In cups that had voids, we computed (1) the number of voids, (2) their volume and the cup volume fraction, (3) their sphericity, (4) size, and (5) their location. The cups had median mass, volume, and density of 208.5 g, 46,471 mm3 , and 4.42 g/cm3 , respectively. Five cups were found to contain a median (range) of 90 (58-101) structural voids. The median void volume and cup volume fractions of cups with voids were 5.17 (1.05-17.33) mm3 and 99.983 (99.972-99.998)%, respectively. The median void sphericity and size were 0.47 (0.19-0.65) and 0.64 (0.27-8.82) mm, respectively. Voids were predominantly located adjacent to screw holes, within flanges, and at the transition between design features; these were between 0.17 and 4.66 mm from the cup surfaces. This is the first study to examine defects within final-production 3D-printed custom cups, providing data for regulators, surgeons, and manufacturers about the variability in final print quality. The size, shape, and location of these voids are such that there may be an increased risk of crack initiation from them.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Microtomografia por Raio-X , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Impressão Tridimensional
2.
3D Print Med ; 8(1): 33, 2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36342573

RESUMO

BACKGROUND: 3D printed patient-specific titanium acetabular cups are used to treat patients with massive acetabular defects. These have highly porous surfaces, with the design intent of enhancing bony fixation. Our aim was to characterise these porous structures in commercially available designs. METHODS: We obtained 12 final-production, patient-specific 3D printed acetabular cups that had been produced by 6 manufacturers. High resolution micro-CT imaging was used to characterise morphometric features of their porous structures: (1) strut thickness, 2) the depth of the porous layer, (3) pore size and (4) the level of porosity. Additionally, we computed the surface area of each component to quantify how much titanium may be in contact with patient tissue. Statistical comparisons were made between the designs. RESULTS: We found a variability between designs in relation to the thickness of the struts (0.28 to 0.65 mm), how deep the porous layers are (0.57 to 11.51 mm), the pore size (0.74 to 1.87 mm) and the level of porosity (34 to 85%). One manufacturer printed structures with different porosities between the body and flange; another manufacturer had two differing porous regions within the body of the cups. The cups had a median (range) surface area of 756.5 mm2 (348 - 1724). CONCLUSIONS: There is a wide variability between manufacturers in the porous titanium structures they 3D print. We do not currently know whether there is an optimal porosity and how this variability will impact clinically on the integrity of bony fixation; this will become clearer as post market surveillance data is generated.

3.
J Pers Med ; 11(8)2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34442421

RESUMO

The accuracy of the implant's post-operative position and orientation in reverse shoulder arthroplasty is known to play a significant role in both clinical and functional outcomes. Whilst technologies such as navigation and robotics have demonstrated superior radiological outcomes in many fields of surgery, the impact of augmented reality (AR) assistance in the operating room is still unknown. Malposition of the glenoid component in shoulder arthroplasty is known to result in implant failure and early revision surgery. The use of AR has many promising advantages, including allowing the detailed study of patient-specific anatomy without the need for invasive procedures such as arthroscopy to interrogate the joint's articular surface. In addition, this technology has the potential to assist surgeons intraoperatively in aiding the guidance of surgical tools. It offers the prospect of increased component placement accuracy, reduced surgical procedure time, and improved radiological and functional outcomes, without recourse to the use of large navigation or robotic instruments, with their associated high overhead costs. This feasibility study describes the surgical workflow from a standardised CT protocol, via 3D reconstruction, 3D planning, and use of a commercial AR headset, to AR-assisted k-wire placement. Post-operative outcome was measured using a high-resolution laser scanner on the patient-specific 3D printed bone. In this proof-of-concept study, the discrepancy between the planned and the achieved glenoid entry point and guide-wire orientation was approximately 3 mm with a mean angulation error of 5°.

4.
Knee ; 21(5): 964-70, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25086900

RESUMO

BACKGROUND: Results of knee replacement registries have shown that unicompartmental knee arthroplasty (UKA) has a significantly higher revision and failure rate than current state-of-the-art TKA. The aim of this prospective study is to evaluate the long-term outcomes and to calculate the 10 year survival of knees with medial osteoarthritis treated with Uniglide® UKA. METHODS: Two hundred thirty-four patients were assessed by an independent clinical observer using the American Knee Society Clinical Rating System, a validated outcome measure. Kaplan-Meier analysis was used to calculate the 10 year survival rates using revision surgery for any cause as the end point. RESULTS: There were no revisions due to progression of lateral osteoarthritis or polyethylene failure. There were one traumatic and three non-traumatic bearing dislocations and two revisions due to aseptic loosening of the tibial component. One joint was revised for traumatic ligament rupture, one for synovitis from bearing impingement, one due to femoral component mal-positioning and one for infection. A total of 10 cases were revised due to failures for any cause in the 61 patients withdrawn because they had died, thus giving a cumulative survival rate at 10 years of 95.57%. The knee (function) score showed an increase from 33.4 (54.7) pre-operatively to 94 (83.4) points post-operatively. The average range of motion increased from 107 to 122° (p<0.01). CONCLUSION: Based on our findings we believe that the Uniglide® unicompartmental knee prosthesis offers a safe and effective solution for the treatment of medial compartment osteoarthritis.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular , Reoperação , Fatores de Tempo , Resultado do Tratamento
5.
Hip Int ; 19(4): 323-9, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20041378

RESUMO

CT when compared to plain radiograph is known to be a more valid measure of acetabular component orientation. The validity of plain radiographs may be further compromised by large diameter metal femoral heads because of obscuration of the acetabular rim. We quantified this effect by measuring acetabular cup angles (inclination and version) of 49 metal on metal (MOM) hip resurfacings using plain radiographs and 3D CT based measurement. Bland-Altman plots revealed poor agreement between plain radiographic and CT based measurement with 2 standard deviation limits of agreements of: +7 to -15 degrees for cup inclination angle; and +16 to -31 degrees for cup version angle. The large differences between plain radiographic and CT measurement of cup positions are probably due to the large diameter metal femoral head that can obscure the cup margin. We have used a metal artefact reduction CT protocol with a 3D imaging software package to overcome this problem and measure cup position relative to the Anterior Pelvic Plane.


Assuntos
Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril/efeitos adversos , Humanos , Variações Dependentes do Observador , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS