Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 70: 28-42, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27693217

RESUMO

Modulating deformation mechanism through manipulating morphological parameters of scaffold internal pore architecture provides potential to tailor the overall mechanical properties under physiological loadings. Whereas cells sense local strains, cell differentiation is also impressed by the elastic deformations. In this paper, structure-property relations were developed for Ti6-Al-4V scaffolds designed based on triply periodic minimal surfaces. 10mm cubic scaffolds composed of 5×5×5 unit cells formed of F-RD (bending dominated) and I-WP (stretching dominated) architectures were additively manufactured at different volume fractions and subjected to compressive tests. The first stages of deformation for stretching dominated structure, was accompanied by bilateral layer-by-layer failure of unit cells owing to the buckling of micro-struts, while for bending dominated structure, namely F-RD, global shearing bands appeared since the shearing failure of struts in the internal architecture. Promoted mechanical properties were found for stretching dominated structure since the global orientation of struts were parallel to loading direction while inclination of struts diminished specific properties for bending dominated structure. Moreover, elastic-plastic deformation was computationally studied by applying Johnson-Cook damage model to the voxel-based models in FE analysis. Scaling analysis was performed for mechanical properties with respect to the relative density thereby failure mechanism was correlated to the constants of power law describing mechanical properties.


Assuntos
Materiais Biocompatíveis/análise , Próteses e Implantes , Fenômenos Biomecânicos , Porosidade
2.
MethodsX ; 3: 219-30, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27054098

RESUMO

Atomistic simulations have now become commonplace in the study of the deformation and failure of materials. Increase in computing power in recent years has made large-scale simulations with billions, or even trillions, of atoms a possibility. Most simulations to-date, however, are still performed with quasi-2D geometries or rather simplistic 3D setups. Although controlled studies on such well-defined structures are often required to obtain quantitative information from atomistic simulations, for qualitative studies focusing on e.g. the identification of mechanisms, researchers would greatly benefit from a methodology that helps realize more realistic configurations. The ideal scenario would be a one-on-one reconstruction of experimentally observed structures. To this end, we propose a new method and software tool called nano sculpt with the following features:•The method allows for easy sample generation for atomistic simulations from any arbitrarily shaped 3D enclosed volume.•The tool can be used to build atomistic samples from artificial geometries, including CAD geometries and structures obtained from simulation methods other than atomistic simulations.•The tool enables the generation of experimentally informed atomistic samples, by e.g. digitization of micrographs or usage of tomography data.

3.
J Mech Behav Biomed Mater ; 50: 180-91, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26143351

RESUMO

Since the advent of additive manufacturing techniques, regular porous biomaterials have emerged as promising candidates for tissue engineering scaffolds owing to their controllable pore architecture and feasibility in producing scaffolds from a variety of biomaterials. The architecture of scaffolds could be designed to achieve similar mechanical properties as in the host bone tissue, thereby avoiding issues such as stress shielding in bone replacement procedure. In this paper, the deformation and failure mechanisms of porous titanium (Ti6Al4V) biomaterials manufactured by selective laser melting from two different types of repeating unit cells, namely cubic and diamond lattice structures, with four different porosities are studied. The mechanical behavior of the above-mentioned porous biomaterials was studied using finite element models. The computational results were compared with the experimental findings from a previous study of ours. The Johnson-Cook plasticity and damage model was implemented in the finite element models to simulate the failure of the additively manufactured scaffolds under compression. The computationally predicted stress-strain curves were compared with the experimental ones. The computational models incorporating the Johnson-Cook damage model could predict the plateau stress and maximum stress at the first peak with less than 18% error. Moreover, the computationally predicted deformation modes were in good agreement with the results of scaling law analysis. A layer-by-layer failure mechanism was found for the stretch-dominated structures, i.e. structures made from the cubic unit cell, while the failure of the bending-dominated structures, i.e. structures made from the diamond unit cells, was accompanied by the shearing bands of 45°.


Assuntos
Materiais Biocompatíveis/química , Fenômenos Mecânicos , Ligas , Força Compressiva , Lasers , Modelos Moleculares , Conformação Molecular , Porosidade , Estresse Mecânico , Titânio/química
4.
Mol Cell Biomech ; 10(1): 27-42, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24010244

RESUMO

Owing to the apparent simple morphology and peculiar properties, nacre, an iridescent layer, coating of the inner part of mollusk shells, has attracted considerable attention of biologists, material scientists and engineers. The basic structural motif in nacre is the assembly of oriented plate-like aragonite crystals with a 'brick' (CaCO3 crystals) and 'mortar' (macromolecular components like proteins) organization. Many scientific researchers recognize that such structures are associated with the excellent mechanical properties of nacre and biomimetic strategies have been proposed to produce new layered nanocomposites. During the past years, increasing efforts have been devoted towards exploiting nacre's structural design principle in the synthesis of novel nanocomposites. However, the direct transfer of nacre's architecture to an artificial inorganic material has not been achieved yet. In the present contribution we report on laminated architecture, composed of the inorganic oxide (TiO2) and organic polyelectrolyte (PE) layers which fulfill this task. To get a better insight and understanding concerning the mechanical behaviour of bio-inspired layered materials consisting of oxide ceramics and organic layers, the elastic-plastic properties of titanium dioxide and organic polyelectrolyte phase are determined via FE-modelling of the nanoindentation process. With the use of inverse modeling and based on numerical models which are applied on the microscopic scale, the material properties of the constituents are derived.


Assuntos
Exoesqueleto/química , Materiais Biomiméticos/química , Modelos Químicos , Moluscos/química , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Titânio/química , Animais , Força Compressiva , Simulação por Computador , Módulo de Elasticidade , Eletrólitos/química , Dureza , Teste de Materiais , Estresse Mecânico , Resistência à Tração
5.
J Microsc ; 201(2): 171-178, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11207919

RESUMO

The deformation characteristics of the metal matrix composites Ag/Ni and Al/Al2O3 are studied at microstructural level by a scanning electron microscopebased grating method and finite element (FE) simulation. The measured strain was found to localize in narrow bands in the ductile matrix of both composites. In the case of the Al/Al2O3 composite, the bands are preferentially initiated in Al regions adjacent to the interface of large Al2O3 particles, leading to local strain maxima. The band positions found in the Ag/Ni composite are also affected by the less deformable Ni phase, but strain localization first occurs by sliding of single Ag grains sometimes located away from the Ni phase. Using a FE model of real phase geometry and measured border displacements as boundary conditions, the simulation agrees reasonably with the experiment. The differences in the case of the Al/Al2O3 composite are due to particle cracks and voids at the particle/matrix interface. This effect was found in the experiment but not considered in modelling. For the Ag/Ni composite the band positions agree fairly well. However, the level and gradient of strain is clearly different as the crystallographic orientation of the Ag grains was not accounted for in modelling.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...