Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Arch Orthop Trauma Surg ; 142(10): 2911-2917, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34453205

RESUMO

BACKGROUND: Higher complication rates have been reported for total hip arthroplasty (THA) after osteosynthesis of proximal femur fractures (PFF). This study evaluated the infection risk for conversion of internal fixation of PFF to THA by a single-staged procedure in the absence of clear infection signs. METHODS: Patients undergoing a one-staged conversion to THA (2013-2018) after prior internal fixation of the proximal femur were included. Preoperative diagnostics with laboratory results, hip aspirations as well as intraoperative microbiology and sonication were assessed. Postoperative complications were recorded as well as patient demographics, duration between initial and conversion to THA, explanted osteosynthesis and implanted THA. RESULTS: Fifty-eight patients (24 male/34 female, 62.8 ± 14.5 years) were included with a mean time of 3.8 ± 7.5 years between internal fixation and conversion to THA (45 cementless, 3 cemented, 3 hybrid and 7 hybrid inverse THAs). Preoperative mean blood level CRP was 8.36 ± 14 mg/l (reference value < 5 mg/l) and leukocyte count was 7.11 ± 1.84^3/µl (4.5-10.000^3/µl). Fifty patients had intraoperative microbiological diagnostics, with either swabs in 86.2% and/or sonication in 29.3%. Positive microbiological results were recorded in 10% (5 of 50 patients), with pathogens identified being mainly Staphylococcus. Complications after conversion occurred in 9.6% including a postoperative low-grade infection rate of 5.8% after a mean of 2.5 years. CONCLUSION: This study found a positive microbiological test result in 10% of a one-stage conversion of PFF fixation to THA. Moreover, we found a high infection rate (5.8%) for early postoperative periprosthetic joint infection. Interestingly, CRP has not been proven to be an adequate parameter for low-grade infections or occult colonized implants. Therefore, we recommend a comprehensive pre- and intraoperative diagnostic including hip aspiration, swabs and sonication when considering one-staged revision.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Artrite Infecciosa/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Feminino , Fraturas do Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Complicações Pós-Operatórias/etiologia , Reoperação/efeitos adversos , Estudos Retrospectivos , Fatores de Risco
2.
Eur Radiol ; 29(11): 6038-6048, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31028444

RESUMO

OBJECTIVES: Globalization and migration are increasing the demand for reports in different languages. We aimed to examine if structured reports created by non-German-speaking radiologists with multilingual templates show significant differences in quality to structured reports and free-text reports by German native speakers. METHODS: We used structured templates that allow radiologists to report in their mother tongue and then switch the report language to German or English automatically using proprietary software. German- and English-speaking radiology residents created structured reports in both German and English with these templates. Reports for three different exam types were created (intensive care chest x-ray, shoulder x-ray specifically for degenerative processes, and CT pulmonary angiogram for pulmonary embolism). The report quality of automatically translated German structured reports by English-speaking radiologists and German structured reports by German radiologists was then evaluated by German clinicians with a standardized questionnaire. The questionnaire was designed to assess attributes including content, comprehensibility, clinical consequences, and overall quality. RESULTS: Structured reports by English-speaking radiologists that were automatically translated into German and German structured reports by German radiologists both received very high or high overall quality ratings in the majority of cases, showing no significant differences in quality. Likewise, no significant differences were observed between the two report types regarding comprehensibility and clinical consequences. Structured reports by German radiologists received significantly better ratings for overall quality and comprehensibility compared to free-text reports by German radiologists. CONCLUSIONS: Multilingual structured reporting templates may serve as a feasible tool for creating high-quality radiology reports in foreign languages. KEY POINTS: • Multilingualism in structured reporting templates can be a useful tool for creating high-quality radiology reports in foreign languages. • German reports created with multilingual structured reporting templates by English-speaking radiologists and German structured reports by German radiologists exhibit no significant differences in overall report quality. • Multilingual structured reporting templates can help radiologists overcome communication barriers and facilitate teleradiology.


Assuntos
Idioma , Multilinguismo , Sistemas de Informação em Radiologia/estatística & dados numéricos , Radiologia/estatística & dados numéricos , Relatório de Pesquisa/normas , Humanos , Reprodutibilidade dos Testes
3.
Oper Orthop Traumatol ; 30(6): 457-468, 2018 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-30194642

RESUMO

OBJECTIVE: The dysplastic acetabulum is shifted three-dimensionally outwards and forwards. INDICATIONS: Symptomatic residual hip dysplasias and hip subluxations in skeletally mature patients up to the age of 50 years. Sharp's acetabular up to 60°, as an exception above 60°. CONTRAINDICATIONS: Acetabular retroversion. Radiographic joint space at the lateral acetabular edge that is less than half the normal thickness for the patient's age. Relative contraindication: Elongated leg on the affected side. SURGICAL TECHNIQUE: Ilioinguinal approach in a supine position. Division of the innominate bone. Pivoting the distal osteotomy fragment outwards and forwards with the aid of the Salter maneuver. Fixing the fragments with a guide wire. Final correction of the osteotomy fragments. Force fitting of a dovetail grooved, wedge-shaped bone graft. Insertion of a cannulated compression screw and two further threaded rods. Wound closure. POSTOPERATIVE MANAGEMENT: Unloaded 3­point walking for 4 weeks. Increasing weight bearing from week 4. Full weight bearing from week 10-12. RESULTS: A total of 45 consecutive patients (7 men, 38 women, 49 hips) underwent surgery. Average age at surgery was 27.6 years. The Sharp acetabular angle improved from preoperatively 45.7°â€¯± 4.2° by 13.8° to 32.0°â€¯± 6.4°; the Wiberg (LCE) angle increased from 15.4°â€¯± 9.3° by 19.5° to 34.9°â€¯± 10° postoperatively. The anterior center edge (ACE) angle increased from 28.9°â€¯± 10.4° by 8.6°â€¯± 2.3° to 37.5°â€¯± 8.1°. Complications requiring surgical intervention occurred in 7 patients.


Assuntos
Luxação do Quadril , Osteotomia/métodos , Acetábulo , Adulto , Feminino , Luxação do Quadril/cirurgia , Luxação Congênita de Quadril , Articulação do Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Resultado do Tratamento
4.
Orthopade ; 46(2): 142-147, 2017 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-28083683

RESUMO

BACKGROUND: In case of hip revision arthroplasty, one component (cup/stem) is often well fixed and does not need to be exchanged. The newly implanted component needs to be compatible with the well-fixed implant. The combination of implants from different companies leads to "mix and match" or even mismatch between the implants. OBJECTIVES AND METHODS: The objective of this work was to describe possible combinations including their specifications that need to be considered in partial exchange of hip prostheses. For this purpose the literature, surgical techniques of companies and judgements concerning this topic were analysed and our own results and experiences were included. RESULTS AND CONCLUSIONS: Partial revision arthroplasty can be challenging and needs to be planned in detail. In case of isolated cup or inlay revision with exchange of a modular head the cone of the stem needs to be identified. A ceramic head may be used in revision with a titanium sleeve even from a different company as long as they are compatible. Patients however need to give their informed consent for this mix and match procedure. This procedure is done frequently and good study results support this, however from a juristic point of view a definite recommendation cannot be given. If the inlay of a cup is replaced, the original inlay should be used. If this is not available anymore, it can be manufactured as a special product in many cases. If this is also not possible, an inlay can also be cemented into a well-fixed cup. Biomechanical and clinical studies support this off-label technique. In case of an isolated exchange of the stem with a ceramic inlay that is retained in a well-fixed cup, the revision stem and ceramic head need to be from the same company as the cup. In case of ceramic fracture, a ceramic head with a titanium sleeve should be combined with a PE or ceramic inlay, a metal head or inlay should never be used.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Reoperação/instrumentação , Reoperação/métodos , Acetabuloplastia/instrumentação , Acetabuloplastia/métodos , Acetábulo/cirurgia , Terapia Combinada , Medicina Baseada em Evidências , Humanos , Osteotomia/instrumentação , Osteotomia/métodos , Desenho de Prótese , Procedimentos de Cirurgia Plástica/instrumentação , Procedimentos de Cirurgia Plástica/métodos , Resultado do Tratamento
5.
Orthopade ; 46(1): 78-84, 2017 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-27921130

RESUMO

BACKGROUND: Certification according to EndoCert in the field of arthroplasty in Germany aims at standardization of treatment and with this optimization of its quality. However, huge capital investment and efforts are necessary. There are currently more than 400 certified centres in Germany. Our Department of Orthopaedics at a German medical school was certified in the pilot phase. The aim of this study was to analyse whether there was a difference in the quality in the year after the certification. A second aim was to analyse whether the defined quality criteria are adequate for a university hospital. MATERIALS AND METHODS: The quality criteria as defined by EndoCert were analysed in the year before (2011) and after certification (2012). The observed complications were noted for 1 year postoperatively. The clinical outcome was analysed with Western Ontario and McMaster University Osteoarthritis Index Score (WOMAC) 1 year postoperatively. RESULTS: There was no difference concerning the criteria analysed, including the clinical outcome in the year before and that after certification. In both years, nearly all criteria could be reached except the operation time and the infection rate in hip and knee revision surgery. CONCLUSION: Certification did not lead to a measurable change of the quality of care. Nearly all criteria, except the infection rate in revision arthroplasty (required: less than 3% at 1 year postop.) and the operation duration could be fulfilled. This rate as well as the operation duration should be revised. Certification according to EndoCert is an important tool to prove quality care, however big efforts and capital are needed. The criteria should be constantly revised and reduced, as these resources should not be missed in patient care.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Artroplastia de Quadril/normas , Artroplastia do Joelho/estatística & dados numéricos , Artroplastia do Joelho/normas , Certificação/normas , Complicações Pós-Operatórias/epidemiologia , Melhoria de Qualidade/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Resultado do Tratamento
6.
J Biomech ; 47(14): 3509-16, 2014 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-25278045

RESUMO

Cementless surface replacement arthroplasty (CSRA) of the shoulder was designed to preserve the individual anatomy and humeral bone stock. A matter of concern in resurfacing implants remains the stress shielding and bone remodeling processes. The bone remodeling processes of two different CSRA fixation designs, conical-crown (Epoca RH) and central-stem (Copeland), were studied by three-dimensional (3-D) finite element analysis (FEA) as well as evaluation of contact radiographs from human CSRA retrievals. FEA included one native humerus model with a normal and one with a reduced bone stock quality. Compressive strains were evaluated before and after virtual CSRA implantation and the results were then compared to the bone remodeling and stress-shielding pattern of eight human CSRA retrievals (Epoca RH n=4 and Copeland n=4). FEA revealed for both bone stock models increased compressive strains at the stem and outer implant rim for both CSRA designs indicating an increased bone formation at those locations. Unloading of the bone was seen for both designs under the central implant shell (conical-crown 50-85%, central-stem 31-93%) indicating high bone resorption. Those effects appeared more pronounced for the reduced than for the normal bone stock model. The assumptions of the FEA were confirmed in the CSRA retrieval analysis which showed bone apposition at the outer implant rim and stems with highly reduced bone stock below the central implant shell. Overall, clear signs of stress shielding were observed for both CSRAs designs in the in vitro FEA and human retrieval analysis. Especially in the central part of both implant designs the bone stock was highly resorbed. The impact of these bone remodeling processes on the clinical outcome as well as long-term stability requires further evaluation.


Assuntos
Artroplastia de Substituição/métodos , Remodelação Óssea/fisiologia , Análise de Elementos Finitos , Articulação do Ombro/fisiologia , Articulação do Ombro/cirurgia , Estresse Mecânico , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Substituição/instrumentação , Densidade Óssea/fisiologia , Reabsorção Óssea/fisiopatologia , Força Compressiva/fisiologia , Feminino , Humanos , Úmero/fisiopatologia , Úmero/cirurgia , Prótese Articular , Masculino , Pessoa de Meia-Idade , Modelos Biológicos
7.
Oper Orthop Traumatol ; 26(2): 171-83, 2014 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-24699924

RESUMO

OBJECTIVE: Total hip arthroplasty with a minimal-incision technique that can be performed in the widely used supine position. The accustomed and good overview of this position allows safe positioning of the implant and combines this with the advantage of a soft tissue preserving technique. All standard instruments and implants can be further applied. INDICATIONS: Primary and secondary coxarthrosis, femoral head necrosis. CONTRAINDICATIONS: Revision surgery, severe anatomic deformity, implantation of hip resurfacing arthroplasty. SURGICAL TECHNIQUE: Supine position. The skin incision runs from the innominate tubercle proximally and falls slightly in the dorsal direction (20-30°). Incision of the iliotibial tract and exposure of the vastogluteal muscle sling. Starting from the greater trochanter, the sinewy onset of the minimal and medium gluteal muscle is split with an arched-shaped incision, which also falls proximally in the dorsal direction. Exposition of the joint capsule, longitudinal incision and resection of the ventrolateral parts. Dislocation of the hip by a combined adduction and external rotation movement. Osteotomy of the femoral neck and resection of the femoral head are performed in a figure-of-four position without adduction. To prepare the acetabulum and to insert the cup, the leg is placed in neutral position with a slight flexion of 20° in the hip. Preparation of the femur and implantation of the stem is again performed in a figure-of-four position in adduction. Reduction of the hip and stepwise wound closure. POSTOPERATIVE MANAGEMENT: Mobilization on postoperative day 1. Starting with half weight bearing and after completed wound healing rapid increase to full weight bearing. Intensive physiotherapy and rehabilitation. Thrombosis prophylaxis according to guidelines. RESULTS: The mini-incision approach has successfully been used in our clinic for years. Between September 2004 and November 2005, the less-invasive technique was evaluated in a randomized controlled trial with 51 patients (52 hips). Compared to the standard approach a significantly shorter incision length (8.9 vs. 14.0 cm) and a slightly lower blood loss (502 vs. 660 ml) were observed for the modified mini-Hardinge. Moreover, the mini-incision group showed slightly better functional results in the early course. A higher rate of implant malpositioning or a higher peri- and postoperative complication rate was not observed.


Assuntos
Artroplastia de Quadril/métodos , Necrose da Cabeça do Fêmur/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Osteoartrite do Quadril/cirurgia , Posicionamento do Paciente/métodos , Fraturas Periprotéticas/cirurgia , Feminino , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Fraturas Periprotéticas/diagnóstico por imagem , Radiografia , Decúbito Dorsal , Resultado do Tratamento
8.
Acta Chir Belg ; 113(2): 123-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23741931

RESUMO

BACKGROUND: Hip resurfacing arthroplasty is known to increase the metal ion concentration in the serum, urine and whole blood, with potentially adverse effects on the organism. However, only few data are available about the metal ion concentrations in erythrocytes, although they are directly exposed to the higher concentrations of the serum. METHODS: The ion levels of chromium, cobalt, nickel and molybdenum in erythrocytes of 25 patients with a hip resurfacing implant were analysed with high resolution ICP-sf-MS (inductively-coupled-plasma-sector-field-mass-spectrometry). The results were compared to the ion levels in the serum and urine of the patients, and also to the ion levels of 27 control persons without an implant. RESULTS: Compared to the control group, ion levels in the erythrocytes of the hip resurfacing group were markedly increased for cobalt (0.10 vs. 3.26 microg/kg) and slightly for chromium (6.04 vs. 7.38 microg/kg). In contrast, ion levels in the serum of the hip resurfacing group were increased for cobalt (0.21 vs. 1.92 microg/l), chromium (1.48 vs. 5.64 microg/l), nickel (1.53 vs. 4.25 microg/l) and molybdenum (2.17 vs. 3.78 microg/l). CONCLUSION: Ion concentrations of cobalt and chromium are also increased in erythrocytes after hip resurfacing arthroplasty. Further research is required to evaluate the impact of the elevated ion levels on the erythrocytes, and to evaluate if metal ions also accumulate in other tissues of the body.


Assuntos
Artroplastia de Quadril , Eritrócitos/metabolismo , Prótese de Quadril , Artropatias/metabolismo , Próteses Articulares Metal-Metal , Metais Pesados/metabolismo , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Íons/sangue , Íons/urina , Artropatias/patologia , Artropatias/cirurgia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
10.
Vet Comp Orthop Traumatol ; 25(4): 301-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22534728

RESUMO

OBJECTIVES: The ovine hip is often used as an experimental research model to simulate the human hip. However, little is known about the contact pressures on the femoral and acetabular cartilage in the ovine hip, and if those are representative for the human hip. METHODS: A model of the ovine hip, including the pelvis, femur, acetabular cartilage, femoral cartilage and ligamentum transversum, was built using computed tomography and micro-computed tomography. Using the finite element method, the peak forces were analysed during simulated walking. RESULTS: The evaluation revealed that the contact pressure distribution on the femoral cartilage is horseshoe-shaped and reaches a maximum value of approximately 6 MPa. The maximum contact pressure is located on the dorsal acetabular side and is predominantly aligned in the cranial-to-caudal direction. The surface stresses acting on the pelvic bone reach an average value of approximately 2 MPa. CONCLUSIONS: The contact pressure distribution, magnitude, and the mean surface stress in the ovine hip are similar to those described in the current literature for the human hip. This suggests that in terms of load distribution, the ovine hip is well suited for the preclinical testing of medical devices designed for the human hip.


Assuntos
Artrometria Articular/veterinária , Análise de Elementos Finitos , Articulação do Quadril/anatomia & histologia , Articulação do Quadril/fisiologia , Ovinos/anatomia & histologia , Ovinos/fisiologia , Animais , Fenômenos Biomecânicos , Simulação por Computador , Humanos , Modelos Anatômicos
11.
Orthopade ; 41(4): 298-302, 2012 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-22476420

RESUMO

INTRODUCTION: Unicompartmental knee arthroplasty (UKA) has become a standard procedure with good clinical outcome in patients with isolated medial osteoarthritis of the knee. However, the survival rates of UKA are still inferior compared to that of total knee arthroplasty. Aseptic loosening and wear are responsible for more than 50% of revisions. Therefore, this study evaluated the influence of the tibial slope on the wear rate in a medial UKA. MATERIALS AND METHODS: The wear rate of a medial mobile-bearing UKA (Univation® Aesculap, Tuttlingen, Deutschland) was evaluated according to the ISO 14243-1:2002(E) norm with a customized four-station servo-hydraulic knee wear simulator (EndoLab, Thansau, Germany). In the first group, the prostheses was medially implanted with 0° slope (n = 3) and in the second group the prostheses was medially implanted with 8° slope (n = 3). The lateral side was kept constant with 0° in both groups. For each implant, a total of 5.0 million cycles was performed and after every 0.5 million cycles the gravimetric wear rate was determined. RESULTS: The wear rate in the 0° slope group was 3.46 ± 0.59 mg/million cycles and therefore significantly higher than in the 8° slope group with 0.99 ± 0.42 mg/million cycles (p < 0.01). DISCUSSION: An increase in the tibial slope leads to a reduced wear rate in a mobile-bearing UKA. Therefore, at least for this mobile-bearing UKA a higher tibial slope seems favorable to reduce the wear. However, before an optimal position of the tibial slope can be recommended, further investigations are required to evaluate the influence of the tibial slope on other factors, such as the ligament tension or the strain on the lateral compartment.


Assuntos
Prótese do Joelho , Tíbia/fisiopatologia , Tíbia/cirurgia , Análise de Falha de Equipamento , Humanos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...