Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(9)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38730942

RESUMO

Bone substitutes are ideally biocompatible, osteoconductive, degradable and defect-specific and provide mechanical stability. Magnesium phosphate cements (MPCs) offer high initial stability and faster degradation compared to the well-researched calcium phosphate cements (CPCs). Calcium magnesium phosphate cements (CMPCs) should combine the properties of both and have so far shown promising results. The present study aimed to investigate and compare the degradation and osseointegration behavior of 3D powder-printed wedges of CMPC and MPC in vivo. The wedges were post-treated with phosphoric acid (CMPC) and diammonium hydrogen phosphate (MPC) and implanted in a partially loaded defect model in the proximal rabbit tibia. The evaluation included clinical, in vivo µ-CT and X-ray examinations, histology, energy dispersive X-ray analysis (EDX) and scanning electron microscopy (SEM) for up to 30 weeks. SEM analysis revealed a zone of unreacted material in the MPC, indicating the need to optimize the manufacturing and post-treatment process. However, all materials showed excellent biocompatibility and mechanical stability. After 24 weeks, they were almost completely degraded. The slower degradation rate of the CMPC corresponded more favorably to the bone growth rate compared to the MPC. Due to the promising results of the CMPC in this study, it should be further investigated, for example in defect models with higher load.

2.
Sensors (Basel) ; 24(2)2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38257422

RESUMO

The noise in sensor data has a substantial impact on the reliability and accuracy of (ML) algorithms. A comprehensive framework is proposed to analyze the effects of diverse noise inputs in sensor data on the accuracy of ML models. Through extensive experimentation and evaluation, this research examines the resilience of a LightGBM ML model to ten different noise models, namely, Flicker, Impulse, Gaussian, Brown, Periodic, and others. A thorough analytical approach with various statistical metrics in a Monte Carlo simulation setting was followed. It was found that the Gaussian and Colored noise were detrimental when compared to Flicker and Brown, which are identified as safe noise categories. It was interesting to find a safe threshold limit of noise intensity for the case of Gaussian noise, which was missing in other noise types. This research work employed the use case of changeover detection in (CNC) manufacturing machines and the corresponding data from the publicly funded research project (OBerA).

3.
Sensors (Basel) ; 23(9)2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-37177389

RESUMO

Monitoring the metal Additive Manufacturing (AM) process is an important task within the scope of quality assurance. This article presents a method to gain insights into process quality by comparing the actual and target layers. Images of the powder bed were captured and segmented using an Xception-style neural network to predict the powder and part areas. The segmentation result of every layer is compared to the reference layer regarding the area, centroids, and normalized area difference of each part. To evaluate the method, a print job with three parts was chosen where one of them broke off and another one had thermal deformations. The calculated metrics are useful for detecting if a part is damaged or for identifying thermal distortions. The method introduced by this work can be used to monitor the metal AM process for quality assurance. Due to the limited camera resolutions and inconsistent lighting conditions, the approach has some limitations, which are discussed at the end.

5.
Sensors (Basel) ; 22(24)2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36560384

RESUMO

In recent years, the use of indoor localization techniques has increased significantly in a large number of areas, including industry and healthcare, primarily for monitoring and tracking reasons. From the field of radio frequency technologies, an ultra-wideband (UWB) system offers comparatively high accuracy and is therefore suitable for use cases with high precision requirements in position determination, for example for localizing an employee when interacting with a machine tool on the shopfloor. Indoor positioning systems with radio signals are influenced by environmental obstacles. Although the influence of building structures like walls and furniture was already analysed in the literature before, the influence of metal machine tools was not yet evaluated concerning the accuracy of the position determination. Accordingly, the research question for this article is defined: To what extent is the positioning accuracy of the UWB system influenced by a metal machine tool?The accuracy was measured in a test setup, which consists of a total of four scenarios in a production environment. For this purpose, the visual contact between the transmitter and the receiver modules, including the influence of further interfering factors of a commercially available indoor positioning system, was improved step by step from scenario 1 to 4. A laser tracker was used as the reference measuring device. The data was analysed based on the type A evaluation of standard uncertainty according to the guide to the expression of uncertainty in measurement (GUM). It was possible to show an improvement in standard deviation from 87.64cm±32.27cm to 6.07cm±2.24cm with confidence level 95% and thus provides conclusions about the setup of an indoor positioning system on the shopfloor.


Assuntos
Ondas de Rádio
6.
Biomed Mater ; 18(1)2022 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-36541469

RESUMO

Regenerative bone implants should be completely replaced by new bone within a period of time corresponding to the growth rate of native bone. To meet this requirement, suitable biomaterials must be biodegradable and promote osteogenesis. The combination of slowly degrading but osteoconductive calcium phosphates (CPs) with rapidly degrading and mechanically more resilient magnesium phosphates represents a promising material class for this purpose. In order to create the best possible conditions for optimal implant integration, microporous calcium magnesium phosphate (CMP) cements were processed using 3D powder printing. This technique enables the production of a defect-adapted implant with an optimal fit and a high degree of open porosity to promote bone ingrowth. Four different compositions of 3D printed CMP ceramics were investigated with regard to essential properties of bone implants, including chemical composition, porosity, microstructure, mechanical strength, and cytocompatibility. The ceramics consisted of farringtonite (Mg3(PO4)2) and stanfieldite (Ca4Mg5(PO4)6), with either struvite (NH4MgPO4·6H2O) or newberyite (MgHPO4·3H2O) and brushite (CaHPO4·2H2O) as additional phases. The CMP materials showed open porosities between 13 and 28% and compressive strengths between 11 and 17 MPa, which was significantly higher, as compared with clinically established CP. The cytocompatibility was evaluated with the human fetal osteoblast cell line hFOB 1.19 and was proven to be equal or to even exceed that of tricalcium phosphate. Furthermore, a release of 4-8 mg magnesium and phosphate ions per mg scaffold material could be determined for CMPs over a period of 21 d. In the case of struvite containing CMPs the chemical dissolution of the cement matrix was combined with a physical degradation, which resulted in a mass loss of up to 3.1 wt%. In addition to its beneficial physical and biological properties, the proven continuous chemical degradation and bioactivity in the form of CP precipitation indicate an enhanced bone regeneration potential of CMPs.


Assuntos
Substitutos Ósseos , Humanos , Substitutos Ósseos/química , Estruvita , Magnésio , Fosfatos/química , Fosfatos de Cálcio/química , Cimentos Ósseos/química , Teste de Materiais
7.
Front Bioeng Biotechnol ; 10: 998254, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36246367

RESUMO

Due to the positive effects of magnesium substitution on the mechanical properties and the degradation rate of the clinically well-established calcium phosphate cements (CPCs), calcium magnesium phosphate cements (CMPCs) are increasingly being researched as bone substitutes. A post-treatment alters the materials' physical properties and chemical composition, reinforcing the structure and modifying the degradation rate. By alkaline post-treatment with diammonium hydrogen phosphate (DAHP, (NH4)2HPO4), the precipitation product struvite is formed, while post-treatment with an acidic phosphate solution [e.g., phosphoric acid (PA, H3PO4)] results in precipitation of newberyite and brushite. However, little research has yet been conducted on newberyite as a bone substitute and PA post-treatment of CMPCs has not been described in the accessible literature so far. Therefore, in the present study, the influence of an alkaline (DAHP) or acid (PA) post-treatment on the biocompatibility, degradation behavior, and osseointegration of cylindrical scaffolds (h = 5.1 mm, Ø = 4.2 mm) produced from the ceramic cement powder Ca0.75Mg2.25(PO4)2 by the advantageous manufacturing technique of three-dimensional (3D) powder printing was investigated in vivo. Scaffolds of the material groups Mg225d (DAHP post-treatment) and Mg225p (PA post-treatment) were implanted into the cancellous part of the lateral femoral condyles in rabbits. They were evaluated up to 24 weeks by regular clinical, X-ray, micro-computed tomographic (µCT), and histological examinations as well as scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) analysis and compared with tricalcium phosphate (TCP). All materials showed excellent biocompatibility and rapid osseointegration. While TCP degraded only slightly, the CMPCs showed almost complete degradation. Mg225d demonstrated significantly faster loss of form and demarcability from surrounding bone, scaffold volume reduction, and significantly greater degradation on the side towards the bone marrow than to the cortex than Mg225p. Simultaneously, numerous bone trabeculae have grown into the implantation site. While these were mostly located on the side towards the cortex in Mg225d, they were more evenly distributed in Mg225p and showed almost the same structural characteristics as physiological bone after 24 weeks in Mg225p. Based on these results, the acid post-treated 3D powder-printed Mg225p is a promising degradable bone substitute that should be further investigated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...