Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 68(23)2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-37669669

RESUMO

Objective.To experimentally validate a method to create continuous time-resolved estimated synthetic 4D-computed tomography datasets (tresCTs) based on orthogonal cine MRI data for lung cancer treatments at a magnetic resonance imaging (MRI) guided linear accelerator (MR-linac).Approach.A breathing porcine lung phantom was scanned at a CT scanner and 0.35 T MR-linac. Orthogonal cine MRI series (sagittal/coronal orientation) at 7.3 Hz, intersecting tumor-mimicking gelatin nodules, were deformably registered to mid-exhale 3D-CT and 3D-MRI datasets. The time-resolved deformation vector fields were extrapolated to 3D and applied to a reference synthetic 3D-CT image (sCTref), while accounting for breathing phase-dependent lung density variations, to create 82 s long tresCTs at 3.65 Hz. Ten tresCTs were created for ten tracked nodules with different motion patterns in two lungs. For each dataset, a treatment plan was created on the mid-exhale phase of a measured ground truth (GT) respiratory-correlated 4D-CT dataset with the tracked nodule as gross tumor volume (GTV). Each plan was recalculated on the GT 4D-CT, randomly sampled tresCT, and static sCTrefimages. Dose distributions for corresponding breathing phases were compared in gamma (2%/2 mm) and dose-volume histogram (DVH) parameter analyses.Main results.The mean gamma pass rate between all tresCT and GT 4D-CT dose distributions was 98.6%. The mean absolute relative deviations of the tresCT with respect to GT DVH parameters were 1.9%, 1.0%, and 1.4% for the GTVD98%,D50%, andD2%, respectively, 1.0% for the remaining nodulesD50%, and 1.5% for the lungV20Gy. The gamma pass rate for the tresCTs was significantly larger (p< 0.01), and the GTVD50%deviations with respect to the GT were significantly smaller (p< 0.01) than for the sCTref.Significance.The results suggest that tresCTs could be valuable for time-resolved reconstruction and intrafractional accumulation of the dose to the GTV for lung cancer patients treated at MR-linacs in the future.


Assuntos
Neoplasias Pulmonares , Humanos , Animais , Suínos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética , Pulmão , Tomografia Computadorizada Quadridimensional/métodos , Imagem Cinética por Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Phys Imaging Radiat Oncol ; 27: 100482, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37680905

RESUMO

Background and purpose: In radiotherapy, dose calculations based on 4D cone beam CTs (4DCBCTs) require image intensity corrections. This retrospective study compared the dose calculation accuracy of a deep learning, projection-based scatter correction workflow (ScatterNet), to slower workflows: conventional 4D projection-based scatter correction (CBCTcor) and a deformable image registration (DIR)-based method (4DvCT). Materials and methods: For 26 lung cancer patients, planning CTs (pCTs), 4DCTs and CBCT projections were available. ScatterNet was trained with pairs of raw and corrected CBCT projections. Corrected projections from ScatterNet and the conventional workflow were reconstructed using MA-ROOSTER, yielding 4DCBCTSN and 4DCBCTcor. The 4DvCT was generated by 4DCT to 4DCBCT DIR, as part of the 4DCBCTcor workflow. Robust intensity modulated proton therapy treatment plans were created on free-breathing pCTs. 4DCBCTSN was compared to 4DCBCTcor and the 4DvCT in terms of image quality and dose calculation accuracy (dose-volume-histogram parameters and 3%/3mm gamma analysis). Results: 4DCBCTSN resulted in an average mean absolute error of 87HU and 102HU when compared to 4DCBCTcor and 4DvCT respectively. High agreement was observed in targets with median dose differences of 0.4Gy (4DCBCTSN-4DCBCTcor) and 0.3Gy (4DCBCTSN-4DvCT). The gamma analysis showed high average 3%/3mm pass rates of 96% for both 4DCBCTSN vs. 4DCBCTcor and 4DCBCTSN vs. 4DvCT. Conclusions: Accurate 4D dose calculations are feasible for lung cancer patients using ScatterNet for 4DCBCT correction. Average scatter correction times could be reduced from 10min (4DCBCTcor) to 3.9s, showing the clinical suitability of the proposed deep learning-based method.

3.
Med Phys ; 50(8): 4981-4992, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36847184

RESUMO

BACKGROUND: The treatment of moving tumor entities is expected to have superior clinical outcomes, using image-guided adaptive intensity-modulated proton therapy (IMPT). PURPOSE: For 21 lung cancer patients, IMPT dose calculations were performed on scatter-corrected 4D cone beam CTs (4DCBCTcor ) to evaluate their potential for triggering treatment adaptation. Additional dose calculations were performed on corresponding planning 4DCTs and day-of-treatment 4D virtual CTs (4DvCTs). METHODS: A 4DCBCT correction workflow, previously validated on a phantom, generates 4DvCT (CT-to-CBCT deformable registration) and 4DCBCTcor images (projection-based correction using 4DvCT as a prior) with 10 phase bins, using day-of-treatment free-breathing CBCT projections and planning 4DCT images as input. Using a research planning system, robust IMPT plans administering eight fractions of 7.5 Gy were created on a free-breathing planning CT (pCT) contoured by a physician. The internal target volume (ITV) was overridden with muscle tissue. Robustness settings for range and setup uncertainties were 3% and 6 mm, and a Monte Carlo dose engine was used. On every phase of planning 4DCT, day-of-treatment 4DvCT, and 4DCBCTcor , the dose was recalculated. For evaluation, image analysis as well as dose analysis were performed using mean error (ME) and mean absolute error (MAE) analysis, dose-volume histogram (DVH) parameters, and 2%/2-mm gamma pass rate analysis. Action levels (1.6% ITV D98 and 90% gamma pass rate) based on our previous phantom validation study were set to determine which patients had a loss of dosimetric coverage. RESULTS: Quality enhancements of 4DvCT and 4DCBCTcor over 4DCBCT were observed. ITV D98% and bronchi D2% had its largest agreement for 4DCBCTcor -4DvCT, and the largest gamma pass rates (>94%, median 98%) were found for 4DCBCTcor -4DvCT. Deviations were larger and gamma pass rates were smaller for 4DvCT-4DCT and 4DCBCTcor -4DCT. For five patients, deviations were larger than the action levels, suggesting substantial anatomical changes between pCT and CBCT projections acquisition. CONCLUSIONS: This retrospective study shows the feasibility of daily proton dose calculation on 4DCBCTcor for lung tumor patients. The applied method is of clinical interest as it generates up-to-date in-room images, accounting for breathing motion and anatomical changes. This information could be used to trigger replanning.


Assuntos
Neoplasias Pulmonares , Terapia com Prótons , Humanos , Estudos Retrospectivos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Prótons , Tomografia Computadorizada de Feixe Cônico
4.
Molecules ; 28(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36615598

RESUMO

Tunable aryl alkyl ionic liquids (TAAILs) are ionic liquids (ILs) with a 1-aryl-3-alkylimidazolium cation having differently substituted aryl groups. Herein, nine TAAILs with the bis(trifluoromethylsulfonyl)imide anion are utilized in combination with and without ethylene glycol (EG) as reaction media for the rapid microwave synthesis of platinum nanoparticles (Pt-NPs). TAAILs allow the synthesis of small NPs and are efficient solvents for microwave absorption. Transmission electron microscopy (TEM) shows that small primary NPs with sizes of 2 nm to 5 nm are obtained in TAAILs and EG/TAAIL mixtures. The Pt-NPs feature excellent activity as electrocatalysts in the hydrogen evolution reaction (HER) under acidic conditions, with an overpotential at a current density of 10 mA cm-2 as low as 32 mV vs the reversible hydrogen electrode (RHE), which is significantly lower than the standard Pt/C 20% with 42 mV. Pt-NPs obtained in TAAILs also achieved quantitative conversion in the hydrosilylation reaction of phenylacetylene with triethylsilane after just 5 min at 200 °C.

5.
Biomolecules ; 11(12)2021 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-34944426

RESUMO

Regeneration, the restoration of body parts after injury, is quite widespread in the animal kingdom. Species from virtually all Phyla possess regenerative abilities. Human beings, however, are poor regenerators. Yet, the progress of knowledge and technology in the fields of bioengineering, stem cells, and regenerative biology have fostered major advancements in regenerative medical treatments, which aim to regenerate tissues and organs and restore function. Human induced pluripotent stem cells can differentiate into any cell type of the body; however, the structural and cellular complexity of the human tissues, together with the inability of our adult body to control pluripotency, require a better mechanistic understanding. Planarians, with their capacity to regenerate lost body parts thanks to the presence of adult pluripotent stem cells could help providing such an understanding. In this paper, we used a top-down approach to shortlist blastema transcription factors (TFs) active during anterior regeneration. We found 44 TFs-31 of which are novel in planarian-that are expressed in the regenerating blastema. We analyzed the function of half of them and found that they play a role in the regeneration of anterior structures, like the anterior organizer, the positional instruction muscle cells, the brain, the photoreceptor, the intestine. Our findings revealed a glimpse of the complexity of the transcriptional network governing anterior regeneration in planarians, confirming that this animal model is the perfect playground to study in vivo how pluripotency copes with adulthood.


Assuntos
Perfilação da Expressão Gênica/métodos , Planárias/fisiologia , Fatores de Transcrição/genética , Animais , Regulação da Expressão Gênica no Desenvolvimento , Proteínas de Helminto/genética , Planárias/citologia , Regeneração , Análise de Sequência de RNA
6.
Phys Med Biol ; 66(17)2021 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-34293737

RESUMO

Proton therapy treatment for lungs remains challenging as images enabling the detection of inter- and intra-fractional motion, which could be used for proton dose adaptation, are not readily available. 4D computed tomography (4DCT) provides high image quality but is rarely available in-room, while in-room 4D cone beam computed tomography (4DCBCT) suffers from image quality limitations stemming mostly from scatter detection. This study investigated the feasibility of using virtual 4D computed tomography (4DvCT) as a prior for a phase-per-phase scatter correction algorithm yielding a 4D scatter corrected cone beam computed tomography image (4DCBCTcor), which can be used for proton dose calculation. 4DCT and 4DCBCT scans of a porcine lung phantom, which generated reproducible ventilation, were acquired with matching breathing patterns. Diffeomorphic Morphons, a deformable image registration algorithm, was used to register the mid-position 4DCT to the mid-position 4DCBCT and yield a 4DvCT. The 4DCBCT was reconstructed using motion-aware reconstruction based on spatial and temporal regularization (MA-ROOSTER). Successively for each phase, digitally reconstructed radiographs of the 4DvCT, simulated without scatter, were exploited to correct scatter in the corresponding CBCT projections. The 4DCBCTcorwas then reconstructed with MA-ROOSTER using the corrected CBCT projections and the same settings and deformation vector fields as those already used for reconstructing the 4DCBCT. The 4DCBCTcorand the 4DvCT were evaluated phase-by-phase, performing proton dose calculations and comparison to those of a ground truth 4DCT by means of dose-volume-histograms (DVH) and gamma pass-rates (PR). For accumulated doses, DVH parameters deviated by at most 1.7% in the 4DvCT and 2.0% in the 4DCBCTcorcase. The gamma PR for a (2%, 2 mm) criterion with 10% threshold were at least 93.2% (4DvCT) and 94.2% (4DCBCTcor), respectively. The 4DCBCTcortechnique enabled accurate proton dose calculation, which indicates the potential for applicability to clinical 4DCBCT scans.


Assuntos
Prótons , Algoritmos , Animais , Galinhas , Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Quadridimensional , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares , Masculino , Imagens de Fantasmas , Suínos
7.
Cell Rep ; 5(4): 1142-55, 2013 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-24268775

RESUMO

Planarian regeneration depends on the presence of pluripotent stem cells in the adult. We developed an in vivo stable isotope labeling by amino acids in cell culture (SILAC) protocol in planarians to identify proteins that are enriched in planarian stem cells. Through a comparison of SILAC proteomes of normal and stem cell-depleted planarians and of a stem cell-enriched population of sorted cells, we identified hundreds of stem cell proteins. One of these is an ortholog of nuclear receptor coactivator-5 (Ncoa5/CIA), which is known to regulate estrogen-receptor-mediated transcription in human cells. We show that Ncoa5 is essential for the maintenance of the pluripotent stem cell population in planarians and that a putative mouse ortholog is expressed in pluripotent cells of the embryo. Our study thus identifies a conserved component of pluripotent stem cells, demonstrating that planarians, in particular, when combined with in vivo SILAC, are a powerful model in stem cell research.


Assuntos
Planárias/citologia , Planárias/genética , Células-Tronco Pluripotentes/citologia , Animais , Blastocisto/citologia , Diferenciação Celular/genética , Proliferação de Células , Marcação por Isótopo , Camundongos , Camundongos Endogâmicos C3H , Dados de Sequência Molecular , Coativadores de Receptor Nuclear , Proteoma/genética , Proteômica , Interferência de RNA , RNA Interferente Pequeno , Regeneração/genética , Transcrição Gênica
8.
Int J Dev Biol ; 56(1-3): 117-25, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22450999

RESUMO

The planarian adult stem cell (pASC) population has a specific molecular signature and can be easily visualized and isolated by flow cytometry. However, the lack of antibodies against specific surface markers for planarian cells prevents a deeper analysis of specific cell populations. Here, if we describe the results of the immunoscreening of pASC plasma membrane proteins (PMPs). A novel papain-based method for planarian cell dissociation enabling both high yield and improved cell viability was used to generate single cell preparations for PMP purification. PMPs were used for intraperitoneal immunization of mice and thus about 1000 hybridoma clones were generated and screened. Supernatants collected from the hybridoma clones were first screened by ELISA and then by live immuno-staining. About half of these supernatants stained all the planarian cells, whereas the other half specifically labeled a subfraction thereof. A detailed analysis of two hybridoma supernatants revealed that large subfractions of the X1, X2 and Xin populations differentially express specific membrane markers. Quantitative PCR data disclosed a correlation between the immunostaining results and the expression of markers of the early and late progeny, also for those pASCs in the S/G2/M phase of the cell cycle (X1 population). Thus, about two thirds of the cycling pASCs showed a specific membrane signature coupled with the expression of markers hitherto considered to be restricted to differentiating, post-mitotic progeny. In summary, a library of 66 monoclonal antibodies against planarian PMPs was generated. The analysis of two of the clones generated revealed that a subset of cells of the X1 population expresses early and late progeny markers, which might indicate that these cells are committed while still proliferating. The findings demonstrate the usefulness of our PMP antibody library for planarian research.


Assuntos
Divisão Celular/fisiologia , Fase G2/fisiologia , Proteínas de Membrana/imunologia , Planárias/fisiologia , Fase S/fisiologia , Células-Tronco/fisiologia , Animais , Anticorpos Monoclonais/imunologia , Biomarcadores/metabolismo , Western Blotting , Membrana Celular/imunologia , Membrana Celular/metabolismo , Proliferação de Células , Ensaio de Imunoadsorção Enzimática , Citometria de Fluxo , Hibridomas , Imunização , Técnicas Imunoenzimáticas , Proteínas de Membrana/isolamento & purificação , Proteínas de Membrana/metabolismo , Camundongos , Planárias/citologia , RNA Mensageiro/genética , Reação em Cadeia da Polimerase em Tempo Real , Células-Tronco/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...