Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Radiat Oncol Biol Phys ; 76(4): 1177-84, 2010 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19560880

RESUMO

PURPOSE: Volumetric modulated arc therapy (VMAT), the predecessor to Varian's RapidArc, is a novel extension of intensity-modulated radiotherapy (IMRT) wherein the dose is delivered in a single gantry rotation while the multileaf collimator leaves are in motion. Leaf positions and the weights of field samples along the arc are directly optimized, and a variable dose rate is used. This planning study compared seven-field coplanar IMRT (cIMRT) with VMAT for high-grade gliomas that had planning target volumes (PTVs) overlapping organs at risk (OARs). METHODS AND MATERIALS: 10 previously treated patients were replanned to 60 Gy in 30 fractions with cIMRT and VMAT using the following planning objectives: 98% of PTV covered by 95% isodose without violating OAR and hotspot dose constraints. Mean OAR doses were maximally decreased without reducing PTV coverage or violating hotspot constraints. We compared dose-volume histogram data, monitor units, and treatment times. RESULTS: There was equivalent PTV coverage, homogeneity, and conformality. VMAT significantly reduced maximum and mean retinal, lens, and contralateral optic nerve doses compared with IMRT (p < 0.05). Brainstem, chiasm, and ipsilateral optic nerve doses were similar. For 2-Gy fractions, mean monitor units were as follows: cIMRT = 789 +/- 112 and VMAT = 363 +/- 45 (relative reduction 54%, p = 0.002), and mean treatment times (min) were as follows: cIMRT = 5.1 +/- 0.4 and VMAT = 1.8 +/- 0.1 (relative reduction 65%, p = 0.002). CONCLUSIONS: Compared with cIMRT, VMAT achieved equal or better PTV coverage and OAR sparing while using fewer monitor units and less time to treat high-grade gliomas.


Assuntos
Neoplasias Encefálicas/radioterapia , Glioma/radioterapia , Lesões por Radiação/prevenção & controle , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/patologia , Tronco Encefálico/efeitos da radiação , Fracionamento da Dose de Radiação , Feminino , Glioma/patologia , Humanos , Cristalino/efeitos da radiação , Masculino , Nervo Óptico/efeitos da radiação , Retina/efeitos da radiação , Carga Tumoral
2.
Int J Radiat Oncol Biol Phys ; 76(5): 1480-5, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19625140

RESUMO

PURPOSE: To evaluate the feasibility of using volumetric modulated arc therapy (VMAT) to deliver whole brain radiotherapy (WBRT) with hippocampal avoidance and a simultaneous integrated boost (SIB) for one to three brain metastases. METHODS AND MATERIALS: Ten patients previously treated with stereotactic radiosurgery for one to three brain metastases underwent repeat planning using VMAT. The whole brain prescription dose was 32.25 Gy in 15 fractions, and SIB doses to brain metastases were 63 Gy to lesions >or=2.0 cm and 70.8 Gy to lesions <2.0 cm in diameter. The mean dose to the hippocampus was kept at <6 Gy(2). Plans were optimized for conformity and target coverage while minimizing hippocampal and ocular doses. Plans were evaluated on target coverage, prescription isodose to target volume ratio, conformity number, homogeneity index, and maximum dose to prescription dose ratio. RESULTS: Ten patients had 18 metastases. Mean values for the brain metastases were as follows: conformity number = 0.73 +/- 0.10, target coverage = 0.98 +/- 0.01, prescription isodose to target volume = 1.34 +/- 0.19, maximum dose to prescription dose ratio = 1.09 +/- 0.02, and homogeneity index = 0.07 +/- 0.02. For the whole brain, the mean target coverage and homogeneity index were 0.960 +/- 0.002 and 0.39 +/- 0.06, respectively. The mean hippocampal dose was 5.23 +/- 0.39 Gy(2). The mean treatment delivery time was 3.6 min (range, 3.3-4.1 min). CONCLUSIONS: VMAT was able to achieve adequate whole brain coverage with conformal hippocampal avoidance and radiosurgical quality dose distributions for one to three brain metastases. The mean delivery time was under 4 min.


Assuntos
Neoplasias Encefálicas/radioterapia , Irradiação Craniana/métodos , Olho/efeitos da radiação , Hipocampo/efeitos da radiação , Lesões por Radiação/prevenção & controle , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Neoplasias Encefálicas/secundário , Estudos de Viabilidade , Humanos , Masculino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...