Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 123(16): 165001, 2019 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-31702328

RESUMO

Neutron spectra from secondary ^{3}H(d,n)α reactions produced by an implosion of a deuterium-gas capsule at the National Ignition Facility have been measured with order-of-magnitude improvements in statistics and resolution over past experiments. These new data and their sensitivity to the energy loss of fast tritons emitted from thermal ^{2}H(d,p)^{3}H reactions enable the first statistically significant investigation of charged-particle stopping via the emitted neutron spectrum. Radiation-hydrodynamic simulations, constrained to match a number of observables from the implosion, were used to predict the neutron spectra while employing two different energy loss models. This analysis represents the first test of stopping models under inertial confinement fusion conditions, covering plasma temperatures of k_{B}T≈1-4 keV and particle densities of n≈(12-2)×10^{24} cm^{-3}. Under these conditions, we find significant deviations of our data from a theory employing classical collisions whereas the theory including quantum diffraction agrees with our data.

2.
Rev Sci Instrum ; 86(7): 076105, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26233419

RESUMO

A new radiochemical method for determining deuterium-tritium (DT) fuel and plastic ablator (CH) areal densities (ρR) in high-convergence, cryogenic inertial confinement fusion implosions at the National Ignition Facility is described. It is based on measuring the (198)Au/(196)Au activation ratio using the collected post-shot debris of the Au hohlraum. The Au ratio combined with the independently measured neutron down scatter ratio uniquely determines the areal densities ρR(DT) and ρR(CH) during burn in the context of a simple 1-dimensional capsule model. The results show larger than expected ρR(CH) values, hinting at the presence of cold fuel-ablator mix.

3.
Rev Sci Instrum ; 85(6): 063508, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24985820

RESUMO

We describe a radiochemical measurement of the ratio of isotope concentrations produced in a gold hohlraum surrounding an Inertial Confinement Fusion capsule at the National Ignition Facility (NIF). We relate the ratio of the concentrations of (n,γ) and (n,2n) products in the gold hohlraum matrix to the down-scatter of neutrons in the compressed fuel and, consequently, to the fuel's areal density. The observed ratio of the concentrations of (198m+g)Au and (196g)Au is a performance signature of ablator areal density and the fuel assembly confinement time. We identify the measurement of nuclear cross sections of astrophysical importance as a potential application of the neutrons generated at the NIF.

4.
Phys Rev Lett ; 111(5): 052501, 2013 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-23952390

RESUMO

Neutron time-of-flight spectra from inertial confinement fusion experiments with tritium-filled targets have been measured at the National Ignition Facility. These spectra represent a significant improvement in energy resolution and statistics over previous measurements, and afford the first definitive observation of a peak resulting from sequential decay through the ground state of (5)He at low reaction energies E(c.m.) 100

5.
Rev Sci Instrum ; 83(10): 10D313, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126840

RESUMO

Neutron yields are measured at the National Ignition Facility (NIF) by an extensive suite of neutron activation diagnostics. Neutrons interact with materials whose reaction cross sections threshold just below the fusion neutron production energy, providing an accurate measure of primary unscattered neutrons without contribution from lower-energy scattered neutrons. Indium samples are mounted on diagnostic instrument manipulators in the NIF target chamber, 25-50 cm from the source, to measure 2.45 MeV deuterium-deuterium fusion neutrons through the (115)In(n,n')(115 m) In reaction. Outside the chamber, zirconium and copper are used to measure 14 MeV deuterium-tritium fusion neutrons via (90)Zr(n,2n), (63)Cu(n,2n), and (65)Cu(n,2n) reactions. An array of 16 zirconium samples are located on port covers around the chamber to measure relative yield anisotropies, providing a global map of fuel areal density variation. Neutron yields are routinely measured with activation to an accuracy of 7% and are in excellent agreement both with each other and with neutron time-of-flight and magnetic recoil spectrometer measurements. Relative areal density anisotropies can be measured to a precision of less than 3%. These measurements reveal apparent bulk fuel velocities as high as 200 km/s in addition to large areal density variations between the pole and equator of the compressed fuel.

6.
Rev Sci Instrum ; 83(10): 10D911, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126914

RESUMO

The time decay of several scintillation materials has been measured using the time correlated single photon counting method and a new organic crystal with a highly suppressed delayed light has been identified. Results comparing the light decay of the bibenzyl crystal with a xylene based detector, which is currently installed at National Ignition Facility will be presented.

7.
Rev Sci Instrum ; 79(10): 10E503, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044489

RESUMO

Understanding mix in inertial confinement fusion (ICF) experiments at the National Ignition Facility requires the diagnosis of charged-particle reactions within an imploded target. Radiochemical diagnostics of these reactions are currently under study by scientists at Los Alamos and Lawrence Livermore National Laboratories. Measurement of these reactions requires assay of activated debris and tracer gases from the target. Presented below is an overview of the prompt radiochemistry diagnostic development efforts, including a discussion of the reactions of interest as well as the progress being made to collect and count activated material.

8.
Genes Immun ; 7(2): 169-78, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16437122

RESUMO

A genome-wide screen for asthma and atopy susceptibility alleles conducted in the Hutterites, a founder population of European descent, reported evidence of linkage with a short tandem repeat polymorphism (STRP) within the type I interferon (IFN) gene cluster on chromosome 9p21. The goal of this study was to identify variation within the IFN gene cluster that influences susceptibility to asthma and atopic phenotypes. We screened approximately 25 kb of sequence, including the flanking sequence of all 15 functional genes and the single coding exon in 12, in Hutterites representing different IFNA-STRP genotypes. We identified 78 polymorphisms, and genotyped 40 of these (in 14 genes) in a large Hutterite pedigree. Modest associations (0.003

Assuntos
Asma/genética , Cromossomos Humanos Par 9 , Variação Genética , Interferon Tipo I/genética , Família Multigênica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Alelos , Criança , Suscetibilidade a Doenças , Éxons , Feminino , Mutação da Fase de Leitura , Haplótipos , Heterozigoto , Homozigoto , Humanos , Desequilíbrio de Ligação , Masculino , Pessoa de Meia-Idade , Linhagem , Polimorfismo Genético , Polimorfismo de Nucleotídeo Único
9.
Ultramicroscopy ; 101(2-4): 225-9, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15450667

RESUMO

A surface charge compensation electron flood gun has been added to the Lawrence Livermore National Laboratory (LLNL) highly charged ion (HCI) emission microscope. HCI surface interaction results in a significant charge residue being left on the surface of insulators and semiconductors. This residual charge causes undesirable aberrations in the microscope images and a reduction of the time-of-flight (T-O-F) mass resolution when studying the surfaces of insulators and semiconductors. The benefits and problems associated with HCI microscopy and recent results of the electron flood gun-enhanced HCI microscope are discussed.


Assuntos
Íons/química , Microscopia Eletrônica , Propriedades de Superfície , Microscopia Eletrônica/métodos , Semicondutores , Análise Espectral/métodos
11.
S Afr Med J ; 49(9): 297-8, 1975 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-1114417
13.
J Urol ; 95(5): 625-9, 1966 May.
Artigo em Inglês | MEDLINE | ID: mdl-5935524
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...