Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
2.
Europace ; 11(10): 1387-9, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19648587

RESUMO

Trigger sources of paroxysmal atrial fibrillation (PAF) are not limited to a pulmonary vein origin and may be achievable by cardiac vascular structures like the coronary sinus (CS), the vena cava superior and in some rare cases by a persistent left superior vena cava (LSVC). Cryoballoon ablation has been shown to be effective in pulmonary vein isolation. We report an unusual case of using this technique in the dilated CS in case of a persistent LSVC. A 64 year old patient presented PAF recurrences after cryo pulmonary vein isolation 4 months before. A maintaining pulmonary vein isolation could be demonstrated by transseptal mapping. Further bi-atrial mapping localized repetitive atrial trigger activity in a dilated CS proceeding to a LSVC. A cryoballoon was deployed in the CS target area and during cryoablation the triggered activity suspended. Ablation side effects were excluded by coronary angiography. During a follow up time of 8 months the patient has remained free of PAF recurrences. The current report underlines the importance of a patient-tailored ablation approach. Cryothermic balloon technology may be more applicable in delicate cardiac structures by developing new anatomically adapted balloon shapes and sizes.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo/métodos , Seio Coronário/cirurgia , Criocirurgia/métodos , Sistema de Condução Cardíaco/anormalidades , Sistema de Condução Cardíaco/cirurgia , Veia Cava Superior/anormalidades , Veia Cava Superior/cirurgia , Ablação por Cateter/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 31(10): 1355-7, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18811821

RESUMO

UNLABELLED: Two patients with inconclusive surface electrocardiogram patterns underwent nonfluoroscopy automatic mapping and remote-controlled ablation of nonisthmus and isthmus-dependent right atrial flutter. METHODS AND RESULTS: A 0.08 magnetic vector force and a motor drive enable a complex steering of a new 8-mm magnet tip electrode. The navigation system performs atrial electroanatomical mapping fully automatically. Total procedural fluoroscopy time for ablation of nonisthmus-related atypical and isthmus-dependent flutter was 8.5 and 3.2 minutes, respectively. CONCLUSION: Automatic electroanatomical mapping offers a promising option to effectively guide the remote-controlled ablation of atrial reentry tachycardias and to reduce fluoroscopy time.


Assuntos
Flutter Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Telemedicina/métodos , Campos Eletromagnéticos , Humanos , Resultado do Tratamento
4.
J Am Coll Cardiol ; 52(4): 273-8, 2008 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-18634982

RESUMO

OBJECTIVES: The purpose of this study was to investigate the efficacy safety of the novel cryoballoon device (Arctic Front, Cryocath, Quebec, Canada). BACKGROUND: Antral pulmonary vein (PV) ablation with radiofrequency energy is widely used as a strategy for catheter ablation of paroxysmal atrial fibrillation (PAF). A novel double lumen cryoballoon catheter was designed for circumferential pulmonary vein isolation (PVI) with the cryoablation technique. METHODS: We consecutively enrolled 346 patients with symptomatic, drug refractory paroxysmal (n = 293) or persistent (n = 53) atrial fibrillation (AF). In all patients, PVI of all targeted PVs was the therapeutic aim. The primary end points of this nonrandomized study were: 1) acute isolation rate of targeted PV; and 2) first electrocardiogram-documented recurrence of AF. The secondary end point was occurrence of PV stenosis or atrio-esophageal fistula. RESULTS: The 1,360 of 1,403 PVs (97%) were targeted with balloons or balloons in combination with the use of Freezor Max (Cryocath). We found that ablation with the cryoballoon resulted in maintenance of sinus rhythm in 74% of patients with PAF and 42% of patients with persistent AF. No PV narrowing occurred. The most frequent complication was right phrenic nerve palsy observed during cryoballoon ablation at the right superior PV. CONCLUSIONS: Pulmonary vein isolation with a new cryoballoon technique is feasible. Sinus rhythm can be maintained in the majority of patients with PAF by circumferential PVI using a cryoballoon ablation system. Cryoablation was less effective in patients with persistent AF than in patients with PAF.


Assuntos
Angioplastia com Balão/métodos , Fibrilação Atrial/terapia , Crioterapia , Veias Pulmonares , Idoso , Angioplastia com Balão/instrumentação , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
5.
J Interv Cardiol ; 21(2): 158-66, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18248356

RESUMO

AIMS: Percutaneous coronary intervention (PCI) has been broadly established and often includes highly complex stenoses that require difficult navigation. The purpose of this study is to assess the feasibility of a new magnetic navigation system (MNS) to enable intracoronary guidewire deployment and PCI in daily clinical practice and to compare the 2D guidance to the virtual 3D angioscopy feature. METHODS AND RESULTS: We included 30 consecutive patients (pt) in whom 36 coronary arteries were PCI targets. Patients were randomized to guidewire steering by either 2D guidance or virtual 3D angioscopy (33%). In 31/36 (86%) interventions the MNS guidewire successfully passed the culprit stenosis and the procedure was accomplished by PCI. In 5/30 pt an MNS multivessel intervention was performed. Three of 5 unsuccessful procedures failed due to an unsuccessful recanalization of a subtotal chronic occlusion including 1 pt who required surgical intervention. In 2/36 procedures the magnetic guided intervention was performed effectively after prior conventional failure related to complex anatomy. The contrast medium amount needed to position the magnetic guidewire was 60 +/- 101 mL in 2D accomplished interventions vs. 14 +/- 15 mL in 3D procedures (p < 0.05). In 3 pt the MNS did not harm the implanted pacemaker or defibrillator system. CONCLUSION: Magnetic guided PCI is useful in selected patients. In our experience, success is less likely in evidence of a subtotal occlusion.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioscopia , Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/terapia , Vasos Coronários/cirurgia , Interface Usuário-Computador , Idoso , Meios de Contraste , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Estudos de Viabilidade , Feminino , Humanos , Masculino
6.
Pacing Clin Electrophysiol ; 27(1): 38-46, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14720153

RESUMO

The aim of the study was to define the impact of different high-pass filter settings (HPF) on the accuracy of mapping of ectopic atrial tachycardias (EAT) using a noncontact mapping (NCM) system. In 20 patients with 22 EAT a noncontact probe was deployed in the right (n = 19) or in the left atrium (n = 3). The device enables interpolation and analysis of unipolar electrograms. It provides information on focus localization and signal morphology. These parameters were compared in different HPF of 0.5 Hz, 2 Hz, 8 Hz, and 16 Hz. The NCM signal morphology was preserved at all HPF. An initial negative deflection recorded by NCM system showed a positive predictive value of 93% regarding the ablation success. The deviation (spatial disparity) between visualized focus origin and successful ablation site was 6.9 +/- 5.4 mm. Between two consecutive filter settings, the focus shift was more pronounced between 0.5 and 2 Hz (5.4 +/- 4.5 mm) compared to a setting between 8 and 16 Hz (2.9 +/- 2.9 mm; P < 0.05). Successful ablation was achieved in 15/18 right atrial tachycardias (83%) and in 2/3 left atrial arrhythmias. Different HPF influence NCM spatial analysis of EAT. However, a small variability in foci localization does not impact final ablation results.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter , Taquicardia Atrial Ectópica/fisiopatologia , Taquicardia Atrial Ectópica/cirurgia , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
8.
J Cardiovasc Electrophysiol ; 14(6): 587-90, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12875418

RESUMO

INTRODUCTION: Catheter ablation has become a well-established therapy for isthmus-dependent right atrial flutter (AFL). Recently, mapping and ablation of AFL have been performed using sophisticated three-dimensional mapping systems, such as electroanatomic and noncontact mapping systems. The LocaLisa system enables nonfluoroscopic navigation of intracardiac electrode catheters based on impedance changes related to catheter movements in transthoracic current fields. The aim of this randomized prospective study was to compare the efficacy of the LocaLisa system with the conventional mapping/ablation approach for radiofrequency ablation of AFL. METHODS AND RESULTS: Fifty consecutive patients with AFL (39 men and 11 women; age 65 +/- 10 years) were studied. The patients were randomly assigned to undergo radiofrequency ablation guided by a conventional fluoroscopy-based approach (24 patients) or by the LocaLisa system (26 patients). Ablation success rate and documentation of bidirectional isthmus block were 100% in both groups. Compared with fluoroscopy-guided approaches, LocaLisa-guided procedures demonstrated a reduction in total fluoroscopy time from 15.9 +/- 10.6 minutes to 7.5 +/- 6.5 minutes (P < 0.005). Total fluoroscopy dosage was reduced from 21.0 +/- 19.8 to 8.7 +/- 9.5 Gycm2 (P < 0.05). Fluoroscopy time required for ablation was significantly shortened in the LocaLisa group (2.6 +/- 2.6 min) compared with the conventional approach group (11 +/- 10 min, P < 0.0005). In 9 (35%) of 26 patients, the ablation could be performed with a fluoroscopy time < or = 1 minute. There were no significant differences with regard to the number of radiofrequency applications, fluoroscopy time needed for diagnostic reasons, total procedure time, or other ablation data. CONCLUSION: Compared with the conventional approach, the LocaLisa system significantly reduces the fluoroscopy times needed for ablation of typical AFL.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/instrumentação , Idoso , Estimulação Cardíaca Artificial , Eletrodos Implantados , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fluoroscopia , Seguimentos , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 26(6): 1356-62, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12822752

RESUMO

Whether the electrical activity generated in the pulmonary veins (PVs) during atrial fibrillation (AF) contributes to the maintenance of arrhythmia is not known. The study population consisted of 22 patients (mean age 58 +/- 9.5 years, 16 men) with persistent (12 patients) or intermittent (10 patients) AF. Mapping of the left atrium (LA) was performed with a 64-electrode basket catheter. PVs were mapped simultaneously with the LA with a quadripolar catheter. PV were defined as arrhythmogenic (if frequent ectopic activity induced AF) or nonarrhythmogenic (if no ectopic activity was observed during the procedure). AF cycle lengths in arrhythmogenic and nonarrhythmogenic PV were 130 +/- 50 ms and 152 +/- 42 ms, respectively (P < 0.001). Both were significantly longer than simultaneous AF activity recorded from the posterior wall of the LA (116 +/- 49 ms, P < 0.001). AF cycle lengths in arrhythmogenic PVs as compared to nonarrhythmogenic PVs were: right superior PV 125 +/- 49 ms versus 148 +/- 51 ms; left superior PV 140 +/- 52 ms versus 161 +/- 30 ms; left inferior PV 127 +/- 48 ms versus 147 +/- 45 ms; and right inferior PV 129 +/- 38 versus 152 +/- 44 ms (P < 0.001 for all four comparisons). AF activity in the PV was more organized than in the posterior wall of the LA and the veins were activated in a proximal-to-distal direction during sustained AF episodes. In patients with AF not related to rheumatic heart disease, the posterior wall of the LA has faster activity than the PVs. The AF activity generated inside the PV during sustained AF episodes originates from the posterior wall of the LA rather than from focal firing.


Assuntos
Fibrilação Atrial/fisiopatologia , Átrios do Coração/fisiopatologia , Veias Pulmonares/fisiopatologia , Idoso , Angiografia/métodos , Cateterismo Cardíaco , Eletrofisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
J Invasive Cardiol ; 15(5): 257-62, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12730633

RESUMO

The aim of this study was to investigate the differences between sustained and non-sustained forms of human atrial fibrillation (AF) using multielectrode endocardial recordings. Methods. Sixty-four pole basket catheters were deployed in the right atrium (RA) of 3 groups of patients: 1) patients with persistent AF (> 48 hours); 2) induced sustained AF (> 15 minutes); and 3) induced non-sustained AF (< 15 minutes). Beat to beat AF intervals (FF) were evaluated for each bipole. On the basis of signal characteristics and direction of wavefront propagation, the degree of spatial and temporal organization of AF was assessed. Results. Persistent AF showed the shortest FF intervals (161 ms) and lowest overall degree of AF organization, induced non-sustained AF the longest FF intervals (192 ms) and highest degree of organization. FF intervals of induced sustained AF were only slightly longer (169 ms) compared to persistent AF. Within each AF group, the lateral wall showed the highest degree of organization, the septal region the lowest. Conclusion. In humans, FF interval and overall degree of AF organization were found to increase significantly from sustained to non-sustained AF. Persistent and induced sustained AF, however, only slightly differed in these parameters.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal , Endocárdio/química , Endocárdio/fisiopatologia , Adulto , Idoso , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Segurança de Equipamentos , Estudos de Viabilidade , Feminino , Alemanha , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
11.
Pacing Clin Electrophysiol ; 26(4 Pt 1): 862-9, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12715847

RESUMO

A detailed analysis of the impact of atrial fibrillation (AF) on the voltage of the atrial signals acquired from various right and left atrial regions has not been reported. Thirteen patients (mean age 55 +/- 11 years, range 39-67 years, 5 women) with AF were included in this study. Mapping of the left and the right atrium was performed with 64-electrode basket catheters. AF cycle lengths were calculated over 10-second time intervals using a custom-made software. Voltage of the bipolar signals during AF was calculated by measuring the amplitudes of 30 consecutive signals in the left and the right atria. During sinus rhythm voltage differences between the left (3 +/- 2.9 mV) and the right atrium (2.8 +/- 2.4 mV, P = 0.15) were insignificant. During AF, as compared to sinus rhythm, voltages of the bipolar signals were significantly reduced in the left (0.9 +/- 0.6 mV) and the right (1.3 +/- 1.1 mV) atria (P < 0.001 compared with sinus rhythm). In the left atrium, the posterior wall showed the most pronounced voltage reduction (1.1 +/- 0.8 mV vs 5.3 +/- 4.6 mV, P < 0.001). In the right atrium the septal wall showed the greatest reduction in voltage amplitude (0.8 +/- 0.6 mV vs 2.5 +/- 1.5 mV, P < 0.001). There was a close correlation between the voltage values and the AF cycle length. The smallest voltage values and greatest amplitude reductions were observed during faster and more disorganized AF activity. It is concluded that during AF, the voltage of bipolar signals is significantly reduced as compared to sinus rhythm. The reduction in voltage expresses atrial and regional disparity and correlates strongly with local AF cycle lengths and the degree of AF disorganization.


Assuntos
Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Adulto , Idoso , Análise de Variância , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Desfibriladores Implantáveis , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas
12.
Pacing Clin Electrophysiol ; 26(4 Pt 1): 883-91, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12715850

RESUMO

Due to the anatomic and the functional interatrial relationship, AF is a biatrial process. Whether one of the atria could sustain AF is not known. This study included 11 patients (mean age 57 +/- 10 years, 7 men) with AF who showed a distinct activation pattern, characterized by regular activity in the right atrium (RA) and irregular fibrillatory activity confined to the left atrium (LA) throughout the AF episodes. Each of the atria was mapped with 64-electrode basket catheters. AF was monitored for 74 +/- 26 minutes. Complex and irregular activity with a cycle length of 138 +/- 43 ms was observed in the LA throughout the monitoring time. The posterior and the roof of the LA showed the highest degree of disorganization. RA was activated by regular wavefronts with a cycle length of 194 +/- 22 ms (P < 0.001, compared with LA). No fibrillatory activity was observed in the RA. All wavefronts that activated the RA were of septal origin: high anteroseptal 52%, low posteroseptal 22%, mid-septal 18, and dual wavefronts (from the high anteroseptal and low posteroseptal pathways) 8%. The lateral wall of the RA was activated in a superoinferior direction in 82% of all activations. A left-to-right conduction block during AF and a rotor of fibrillatory activity located in the posterior wall of the LA were observed in two patients. Isolated AF in the LA showed various surface electrocardiographic patterns. It is concluded that LA alone without participation of the RA can sustain AF. These data have implications for mechanisms and the ablative therapy of AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Átrios do Coração , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Mapeamento Potencial de Superfície Corporal , Cateterismo Cardíaco , Ablação por Cateter , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Eur Heart J ; 24(10): 956-62, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12714027

RESUMO

AIMS: The purpose of this study was to evaluate the acute success rate and long-term efficacy of radiofrequency ablation of common type atrial flutter (AFL) by using a standardised anatomical approach in a large series of patients and to assess the influence of right atrial isthmus ablation on the occurrence of atrial fibrillation. There are no large scale prospective or retrospective multicentre studies for radiofrequency ablation of AFL. METHODS AND RESULTS: The study population consisted of 363 consecutive patients with AFL (mean age 58+/-16 years, 265 men) who underwent radiofrequency ablation at the inferior vena cava-tricuspid annulus (IVC-TA) isthmus using a standardised anatomic approach. Bidirectional isthmus block at the IVC-TA was achieved in 328 patients (90%). Following radiofrequency ablation, 343 patients (95%) were followed for a mean of 496+/-335 days. During the follow-up period, 310 patients (90%) remained free of AFL recurrences. Multivariate analysis identified five independent predictors of AFL recurrence: fluoroscopy time (p<0.001), atrial fibrillation after AFL ablation (p=0.01), lack of bidirectional block (p=0.02), reduced left ventricular function (p=0.035) and right atrial dimensions (p=0.046). Atrial fibrillation occurrence was significantly reduced after AFL ablation (112 in 343 patients, 33%) as compared to occurrence of atrial fibrillation before radiofrequency ablation (198 in 363 patients, 55%, p<0.001). CONCLUSIONS: The current anatomical ablation approach for AFL and criteria for evaluation of the IVC-TA isthmus block is associated with an acute success rate of 90% and a long-term recurrence rate of 10%. Radiofrequency ablation of common AFL results in a significant reduction in the occurrence of atrial fibrillation.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Flutter Atrial/fisiopatologia , Criança , Pré-Escolar , Eletrofisiologia , Feminino , Seguimentos , Humanos , Lactente , Masculino , Pessoa de Meia-Idade
14.
Am J Cardiol ; 91(2): 159-63, 2003 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-12521627

RESUMO

Information about the clinical efficacy and complications of the circumferential mapping and isolation of the pulmonary veins (PVs) in patients with atrial fibrillation (AF) is still limited. The present study included 75 patients (mean age 58 +/- 11 years, 20 women) with paroxysmal (n = 69) or persistent AF (n = 6). Mapping of PVs was performed with a circumferential mapping catheter. After preferential PV-left atrium (LA) electric inputs were defined, radiofrequency ablation was performed until complete isolation of the PVs from the LA was achieved. A total of 226 PVs were mapped; 195 (86%) showed typical PV potentials. Complete isolation of PVs from the LA was achieved in 173 PVs (89%). Detailed follow-up, including 7-day Holter monitoring at 1, 4, 9, and 12 months after intervention was performed. If AF reoccurred, PVs were mapped and reisolated. After a mean follow-up period of 230 +/- 133 days, 38 of 75 patients (51%) were in sinus rhythm. At 1, 4, and 9 months of follow-up, 31 of 65 patients (48%), 36 of 53 patients (68%, p = 0.04 as compared with the first month), and 21 of 28 patients (75%, p = 0.025 as compared with the first month), respectively, were in sinus rhythm. During follow-up, 30 patients (40%) underwent a second ablation procedure due to recurrence. Recurrences were related to resumption of PV muscle-left atrial conduction (27 patients) and/or extra PV foci (12 patients) or nonablated PVs (8 patients). Complications occurred in 17 patients (22%). PV stenosis was detected in 13 patients (25% to 50% in 7 patients and >50% in 6 patients). Pericardial effusion occurred in 4 patients. It was concluded that isolation of the PV from the LA is moderately effective in the prevention of AF recurrence and could be associated with serious acute and long-term complications.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Veias Pulmonares/fisiopatologia , Adulto , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Radiografia , Recidiva , Fatores de Risco
15.
Pacing Clin Electrophysiol ; 25(10): 1459-66, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12418744

RESUMO

Catheter ablation of atrial flutter and catheter Maze procedures require the creation of linear lesions. The efficacy of different multipolar catheters to create linear contiguous transmural lesions was studied in a sheep model. In 19 sheep a multipolar ablation catheter was inserted into the right atrium. In nine sheep a steerable 7 Fr catheter (C1) with six 6-mm electrodes and in five sheep a steerable 7 Fr catheter (C2) with four 5-mm electrodes were placed. In five sheep a 3.7 Fr catheter (C3) with eight electrodes of 6-mm length was deployed (steerable sheath). A total of 72 linear lesions were created and evaluated. Catheter types C1, C2, and C3 produced continuous lesions with at least two adjacent electrodes in 45%, 79%, and 87% of the lesions. The mean lesion length achieved by C3 was longer compared to C1 and C2 (27 +/- 14 vs 10 +/- 5 and 11 +/- 6 mm; P < 0.05). The ability to produce contiguous lesions by all available electrodes was low: C1, 5%; C2, 5%; and C3, 6%. C3 was most effective in exerting transmural lesions (93% vs C1 75% and C2 57%; P < 0.0001). Microscopic endocardial fibrinous adhesions and macroscopic mild electrode carbonizations were caused by all catheter types. In conclusion, (1) all three catheter types do not create contiguous lesions along all electrodes. Gaps of viable tissue remain in most instances; (2) lesion depths and transmurality varies with different catheters; and (3) potentially hazardous thrombotic material was observed during radiofrequency ablation with all three catheters.


Assuntos
Ablação por Cateter , Cateterismo , Átrios do Coração/cirurgia , Animais , Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Desenho de Equipamento , Átrios do Coração/patologia , Ovinos
16.
J Cardiovasc Electrophysiol ; 13(10): 980-5, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12435182

RESUMO

INTRODUCTION: Cooled-tip and 8-mm-tip catheters have been found to be more effective than conventional 4-mm-tip catheters for radiofrequency (RF) ablation of common atrial flutter. The aim of this study was to compare the efficacy and safety of cooled-tip and 8-mm-tip catheters for flutter ablation in a randomized, prospective study. METHODS AND RESULTS: In 100 consecutive patients referred for ablation of common atrial flutter, cavotricuspid ablation was performed with a closed cooled-tip catheter (n = 50) or an 8-mm-tip ablation catheter (n = 50). RF current was applied for 60 to 120 seconds at powers of 40 to 50 W with the closed cooled-tip catheter and in a temperature-controlled mode (65 degrees C/70 W) with the 8-mm-tip catheter. The endpoint was achievement of a bidirectional isthmus conduction block. Cross-over was performed after 15 unsuccessful RF applications for each of the catheters. Complete bidirectional isthmus block was achieved in 99% of patients. Cross-over was performed in 11 patients after primary use of the cooled-tip catheter and in 9 patients after primary ablation with the 8-mm-tip catheter. No significant differences were found in the procedure parameters, such as overall RF applications (12.4 +/- 11.3 vs 12.9 +/- 8.6), ablation duration (42 +/- 43 min vs 39 +/- 27 min), and fluoroscopy time (17.0 +/- 18.7 min vs 15.7 +/- 10.7 min). In a mean follow-up of 8.3 months, 1 patient in the cooled-tip group and 3 patients in the 8-mm-tip group had recurrence of common atrial flutter. CONCLUSION: Use of the closed cooled-tip ablation catheter and the 8-mm-tip catheter have equal and high efficacy for RF ablation of common atrial flutter.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/instrumentação , Idoso , Flutter Atrial/complicações , Estudos Cross-Over , Cardioversão Elétrica/instrumentação , Eletrodos Implantados , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Seguimentos , Bloqueio Cardíaco/complicações , Bloqueio Cardíaco/cirurgia , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Recidiva , Reoperação , Resultado do Tratamento
17.
J Interv Cardiol ; 15(5): 407-10, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12440186

RESUMO

We report two cases of directly and indirectly induced catheter carbonizations by radiofrequency application via a large tip ablation catheter. We assume that during a large tip high power delivery of more than 50 watts, an adjacent, smaller-sized, low resistance electrode produces a local increase in the intensity of the current field that is sufficient to elevate the tissue temperature above 100 degrees C. Due to the potential risk of embolism, this may have an impact on ablation procedures in the left atrium and ventricle using similar mapping configurations.


Assuntos
Queimaduras/etiologia , Ablação por Cateter/efeitos adversos , Temperatura , Adulto , Idoso , Ablação por Cateter/instrumentação , Impedância Elétrica , Feminino , Humanos
18.
Am J Cardiol ; 90(11): 1215-20, 2002 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-12450601

RESUMO

Electrophysiologic characterization of the onset and termination of atrial fibrillation (AF) is poorly defined. Our study population consisted of 21 consecutive patients (mean age 58 +/- 9 years, 6 women) with intermittent (10 patients) or persistent (11 patients) AF. Mapping of the left atrium (LA) and the right atrium (RA) during initiation and termination of AF was performed with a 64-electrode basket catheter. A total of 92 spontaneous AF onsets (in 16 patients) and 63 spontaneous AF terminations were analyzed. Irrespective of the origin of the triggering atrial premature complex (APC), the onset of AF was preceded by an intermediary rhythm that consisted of repetitive firing from the focus that generated the initial APC, reentry around the mitral annulus, or typical atrial flutter. The earliest fibrillatory activity was constantly produced by circumvented regions (generators) localized most frequently in the posterior wall of the LA. Generators of fibrillatory activity were not observed in the RA for any of the patients. In the RA, AF is maintained by a mixture of macro-reentry and driving wave fronts of left atrial origin. Four modes of AF termination were observed: a multifocal rhythm (19 episodes, 30%), left atrial tachycardia (17 episodes, 27%), direct conversion to sinus rhythm (15 episodes, 24%), and conversion to typical atrial flutter (12 episodes, 19%). A repetitive rapid rhythm initiated most often by APCs plays a crucial role in the initiation of AF via activation of the generators of fibrillatory activity. The LA plays a central role in the initiation of AF by serving as a substrate for generators of fibrillatory activity. Termination of AF consists of a heterogenous group of unstable rhythms.


Assuntos
Fibrilação Atrial/fisiopatologia , Complexos Cardíacos Prematuros/fisiopatologia , Átrios do Coração/fisiopatologia , Idoso , Fibrilação Atrial/etiologia , Complexos Cardíacos Prematuros/complicações , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas/métodos , Eletrofisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
Ann Noninvasive Electrocardiol ; 7(3): 191-7, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12167178

RESUMO

BACKGROUND: Late potentials represent an arrhythmogenic substrate in chronically infarcted myocardium. It is hypothesized that acute transient ischemia enhances anisotropic electrical ventricular activation and facilitates reentry mechanisms. Study aim was the prospective assessment of the impact of dipyridamole-induced myocardial ischemia on the signal-averaged ECG. METHODS: Dipyridamole stress thallium-201 SPECT imaging was utilized to avoid noise contamination of the signal-averaged ECG from exercise and to document evidence and localization of myocardial ischemia or persistent perfusion defects in 68 patients with suspected coronary artery disease. Before and during dipyridamole-induced vasodilatation serial signal-averaged ECG was performed to evaluate the influence of transient ischemia on the occurrence of late potentials. RESULTS: There was a significant difference between heart rate at rest and heart rate under dipyridamole influence in patients with inducible ischemia (70 +/- 13 vs. 87 +/- 13; P < 0.0001) in contrast to patients without dipyridamole-induced ischemia (74 +/- 20 vs. 80 +/- 16; n.s.). The number of averaged beats and achieved noise level was comparable between both groups. Thirty-three of 68 patients (49%) revealed dipyridamole-induced ischemia; however, no changes of the SAECG parameters, such as QRS, RMS, LAS at 25-250 and 40-250 Hz bandpass filtering in the leads X, Y, Z and vector magnitude, respectively, were observed as a result of ischemia. CONCLUSION: These results suggest that transient myocardial ischemia does not affect the signal-averaged ECG. Clinically, the signal-averaged ECG analysis seems not to be helpful in identifying patients with silent ischemia.


Assuntos
Eletrocardiografia/métodos , Teste de Esforço/métodos , Isquemia Miocárdica/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Análise de Variância , Dipiridamol , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Estudos Prospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Estatísticas não Paramétricas
20.
J Cardiovasc Electrophysiol ; 13(6): 525-32, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12108490

RESUMO

INTRODUCTION: Atrial fibrillation (AF) in the left atrium (LA) is poorly defined in terms of regional differences in the degree of organization, characteristics of paroxysmal and persistent variants, and electrophysiologic events that develop at the onset of episodes. METHODS AND RESULTS: The study population consisted of 21 patients (15 men and 6 women; mean age 58+/-9.4 years) with paroxysmal (10 patients) or persistent (11 patients) AF. Mapping of the LA during sustained episodes and the onset of AF was performed with a 64-electrode basket catheter. At the onset of AF, repetitive beats starting with atrial premature complexes and ending with generation of the earliest fibrillatory activity were defined as intermediary rhythm. Patients with paroxysmal AF had longer AF cycle lengths and more pronounced regional differences than patients with persistent AF. In total, AF cycle lengths in the LA in patients with persistent AF were 20% shorter than in patients with paroxysmal AF. Initiation of AF was preceded by an intermediary rhythm of 5.5+/-2.5 cycles (6.3+/-2.7 cycles in paroxysmal AF vs 4.2+/-1.0 cycles in persistent AF; P = 0.026). At the onset of AF, the earliest generators of fibrillatory activity were located more frequently in the posterior wall of the LA. CONCLUSION: AF in the LA displays substantial regional differences in terms of AF cycle lengths and degree of organization. Patients with persistent AF have shorter cycle lengths and a higher degree of disorganized activity than patients with paroxysmal AF. Intermediary rhythms play an important role in initiation of AF via activation of generator regions in the LA.


Assuntos
Fibrilação Atrial/classificação , Átrios do Coração/fisiopatologia , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Ablação por Cateter , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Complexos Ventriculares Prematuros/classificação , Complexos Ventriculares Prematuros/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...