Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Mol Psychiatry ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38503931

RESUMO

The recent introduction of new-generation immunoassay methods allows the reliable quantification of structural brain markers in peripheral matrices. Neurofilament light chain (NfL), a neuron-specific cytoskeletal component released in extracellular matrices after neuroaxonal impairment, is considered a promising blood marker of active brain pathology. Given its sensitivity to a wide range of neuropathological alterations, NfL has been suggested for the use in clinical practice as a highly sensitive, but unspecific tool to quantify active brain pathology. While large efforts have been put in characterizing its clinical profile in many neurological conditions, NfL has received far less attention as a potential biomarker in major psychiatric disorders. Therefore, we briefly introduce NfL as a marker of neuroaxonal injury, systematically review recent findings on cerebrospinal fluid and blood NfL levels in patients with primary psychiatric conditions and highlight the opportunities and pitfalls. Current evidence suggests an elevation of blood NfL levels in patients with major depression, bipolar disorder, psychotic disorders, anorexia nervosa, and substance use disorders compared to physiological states. However, blood NfL levels strongly vary across diagnostic entities, clinical stage, and patient subgroups, and are influenced by several demographic, clinical, and analytical factors, which require accurate characterization. Potential clinical applications of NfL measure in psychiatry are seen in diagnostic and prognostic algorithms, to exclude neurodegenerative disease, in the assessment of brain toxicity for different pharmacological compounds, and in the longitudinal monitoring of treatment response. The high inter-individual variability of NfL levels and the lack of neurobiological understanding of its release are some of the main current limitations. Overall, this primer aims to introduce researchers and clinicians to NfL measure in the psychiatric field and to provide a conceptual framework for future research directions.

2.
J Psychopharmacol ; 37(9): 942-944, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37401623

RESUMO

Gamma-hydroxybutyrate (GHB, clinically administrated as sodium oxybate) is a GABA-B/GHB receptor agonist inducing prosexual effects and progesterone secretion in humans. As the neuropeptide kisspeptin has well-established roles in regulating sexual behavior and as it was also associated with GABA-B receptor and progesterone function, we investigated the effect of two GHB doses (20 and 35 mg/kg p.o.) on plasma kisspeptin levels in 30 healthy male volunteers, using a double-blind, randomized, placebo-controlled cross-over design. We found no significant alterations of kisspeptin levels after GHB administration compared to placebo. In conclusion, plasma kisspeptin levels are not related to the prosexual effects of GHB.


Assuntos
Oxibato de Sódio , Humanos , Masculino , Oxibato de Sódio/farmacologia , Kisspeptinas/farmacologia , Progesterona/farmacologia , Comportamento Sexual , Voluntários
3.
Sci Rep ; 13(1): 8983, 2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37268859

RESUMO

Gamma-hydroxybutyrate (GHB) remains a challenging clinical/forensic toxicology drug. Its rapid elimination to endogenous levels mainly causes this. Especially in drug-facilitated sexual assaults, sample collection often occurs later than the detection window for GHB. We aimed to investigate new GHB conjugates with amino acids (AA), fatty acids, and its organic acid metabolites for their suitability as ingestion/application markers in urine following controlled GHB administration to humans. We used LC-MS/MS for validated quantification of human urine samples collected within two randomized, double-blinded, placebo-controlled crossover studies (GHB 50 mg/kg, 79 participants) at approximately 4.5, 8, 11, and 28 h after intake. We found significant differences (placebo vs. GHB) for all but two analytes at 4.5 h. Eleven hours post GHB administration, GHB, GHB-AAs, 3,4-dihydroxybutyric acid, and glycolic acid still showed significantly higher concentrations; at 28 h only GHB-glycine. Three different discrimination strategies were evaluated: (a) GHB-glycine cut-off concentration (1 µg/mL), (b) metabolite ratios of GHB-glycine/GHB (2.5), and (c) elevation threshold between two urine samples (> 5). Sensitivities were 0.1, 0.3, or 0.5, respectively. Only GHB-glycine showed prolonged detection over GHB, mainly when compared to a second time- and subject-matched urine sample (strategy c).


Assuntos
Oxibato de Sódio , Humanos , Aminoácidos , Carnitina , Cromatografia Líquida , Espectrometria de Massas em Tandem , Glicina , Detecção do Abuso de Substâncias , Hidroxibutiratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...