Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(18)2020 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-32971940

RESUMO

We have developed a multichannel software defined radio-based transceiver measurement system for use in general microwave tomographic applications. The unit is compact enough to fit conveniently underneath the current illumination tank of the Dartmouth microwave breast imaging system. The system includes 16 channels that can both transmit and receive and it operates from 500 MHz to 2.5 GHz while measuring signals down to -140 dBm. As is the case with multichannel systems, cross-channel leakage is an important specification and must be lower than the noise floors for each receiver. This design exploits the isolation inherent when the individual receivers for each channel are physically separate; however, these challenging specifications require more involved signal isolation techniques at both the system design level and the individual, shielded component level. We describe the isolation design techniques for the critical system elements and demonstrate specification compliance at both the component and system level.

2.
Rev Sci Instrum ; 90(4): 044708, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31042994

RESUMO

We have implemented a prototype 4-channel transmission-based, microwave measurement system built on innovative software defined radio (SDR) technology. The system utilizes the B210 USRP SDR developed by Ettus Research that operates over a 70 MHz-6 GHz bandwidth. While B210 units are capable of being synchronized with each other via coherent reference signals, they are somewhat unreliable in this configuration and the manufacturer recommends using N200 or N210 models instead. For our system, N-series SDRs were less suitable because they are not amenable to RF shielding required for the cross-channel isolation necessary for an integrated microwave imaging system. Consequently, we have configured an external reference that overcame these limitations in a compact and robust package. Our design exploits the rapidly evolving technology being developed for the telecommunications environment for test and measurement tasks with the higher performance specifications required in medical microwave imaging applications. In a larger channel configuration, the approach is expected to provide performance comparable to commercial vector network analyzers at a fraction of the cost and in a more compact footprint.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...