Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 33(3): 1575-1588, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36380195

RESUMO

OBJECTIVES: To assess how an artificial intelligence (AI) algorithm performs against five experienced musculoskeletal radiologists in diagnosing scaphoid fractures and whether it aids their diagnosis on conventional multi-view radiographs. METHODS: Four datasets of conventional hand, wrist, and scaphoid radiographs were retrospectively acquired at two hospitals (hospitals A and B). Dataset 1 (12,990 radiographs from 3353 patients, hospital A) and dataset 2 (1117 radiographs from 394 patients, hospital B) were used for training and testing a scaphoid localization and laterality classification component. Dataset 3 (4316 radiographs from 840 patients, hospital A) and dataset 4 (688 radiographs from 209 patients, hospital B) were used for training and testing the fracture detector. The algorithm was compared with the radiologists in an observer study. Evaluation metrics included sensitivity, specificity, positive predictive value (PPV), area under the characteristic operating curve (AUC), Cohen's kappa coefficient (κ), fracture localization precision, and reading time. RESULTS: The algorithm detected scaphoid fractures with a sensitivity of 72%, specificity of 93%, PPV of 81%, and AUC of 0.88. The AUC of the algorithm did not differ from each radiologist (0.87 [radiologists' mean], p ≥ .05). AI assistance improved five out of ten pairs of inter-observer Cohen's κ agreements (p < .05) and reduced reading time in four radiologists (p < .001), but did not improve other metrics in the majority of radiologists (p ≥ .05). CONCLUSIONS: The AI algorithm detects scaphoid fractures on conventional multi-view radiographs at the level of five experienced musculoskeletal radiologists and could significantly shorten their reading time. KEY POINTS: • An artificial intelligence algorithm automatically detects scaphoid fractures on conventional multi-view radiographs at the same level of five experienced musculoskeletal radiologists. • There is preliminary evidence that automated scaphoid fracture detection can significantly shorten the reading time of musculoskeletal radiologists.


Assuntos
Aprendizado Profundo , Fraturas Ósseas , Osso Escafoide , Traumatismos do Punho , Humanos , Fraturas Ósseas/diagnóstico por imagem , Punho , Estudos Retrospectivos , Inteligência Artificial , Osso Escafoide/diagnóstico por imagem , Radiologistas
2.
Radiol Artif Intell ; 3(4): e200260, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34350413

RESUMO

PURPOSE: To compare the performance of a convolutional neural network (CNN) to that of 11 radiologists in detecting scaphoid bone fractures on conventional radiographs of the hand, wrist, and scaphoid. MATERIALS AND METHODS: At two hospitals (hospitals A and B), three datasets consisting of conventional hand, wrist, and scaphoid radiographs were retrospectively retrieved: a dataset of 1039 radiographs (775 patients [mean age, 48 years ± 23 {standard deviation}; 505 female patients], period: 2017-2019, hospitals A and B) for developing a scaphoid segmentation CNN, a dataset of 3000 radiographs (1846 patients [mean age, 42 years ± 22; 937 female patients], period: 2003-2019, hospital B) for developing a scaphoid fracture detection CNN, and a dataset of 190 radiographs (190 patients [mean age, 43 years ± 20; 77 female patients], period: 2011-2020, hospital A) for testing the complete fracture detection system. Both CNNs were applied consecutively: The segmentation CNN localized the scaphoid and then passed the relevant region to the detection CNN for fracture detection. In an observer study, the performance of the system was compared with that of 11 radiologists. Evaluation metrics included the Dice similarity coefficient (DSC), Hausdorff distance (HD), sensitivity, specificity, positive predictive value (PPV), and area under the receiver operating characteristic curve (AUC). RESULTS: The segmentation CNN achieved a DSC of 97.4% ± 1.4 with an HD of 1.31 mm ± 1.03. The detection CNN had sensitivity of 78% (95% CI: 70, 86), specificity of 84% (95% CI: 77, 92), PPV of 83% (95% CI: 77, 90), and AUC of 0.87 (95% CI: 0.81, 0.91). There was no difference between the AUC of the CNN and that of the radiologists (0.87 [95% CI: 0.81, 0.91] vs 0.83 [radiologist range: 0.79-0.85]; P = .09). CONCLUSION: The developed CNN achieved radiologist-level performance in detecting scaphoid bone fractures on conventional radiographs of the hand, wrist, and scaphoid.Keywords: Convolutional Neural Network (CNN), Deep Learning Algorithms, Machine Learning Algorithms, Feature Detection-Vision-Application Domain, Computer-Aided DiagnosisSee also the commentary by Li and Torriani in this issue.Supplemental material is available for this article.©RSNA, 2021.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...