Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Forensic Sci Int ; 268: 103-115, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27710891

RESUMO

Despite the predominant role played by Internet in the distribution of doping substances, little is currently known about the online offer of doping products. Therefore, the study focuses on the detection of doping substances and suppliers discussed in Internet forums. It aims at having a comprehensive understanding of products and sellers to lead an operational monitoring of the online doping market. Thirteen community forums on the Internet were investigated and one million topics were extracted with source code scrappers. Then, a semantic analysis was conducted with a semi-automatic process to classify the relevant words according to doping matters. Additionally, the ranking of doping products, active substances and suppliers in regards to the number of contributors to the forums were established and analyzed over time. Finally, promotion methods of suppliers were evaluated. The results show that anabolic androgenic steroids, used to enhance body image and performance, are the most discussed type of products. A temporal analysis illustrates the stability of the most popular products as well as the emergence of new products such as peptides (e.g. CJC-1295). 327 suppliers were detected, mostly with dedicated websites or direct sales by e-mail as selling methods. Globally, the implemented methodology shows its ability to detect products and suppliers as well as to follow their temporal trends. The intelligence will serve the definition of online monitoring strategies (e.g. the selection of appropriate keywords). Additionally, it also allows the adjustment of customs inspection strategies and anti-doping analysis by monitoring the popular and emerging substances.


Assuntos
Blogging , Dopagem Esportivo , Internet , Anabolizantes , Tráfico de Drogas , Humanos
2.
Sci Total Environ ; 572: 794-803, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27528480

RESUMO

This study firstly aims to assess the field performances of low density polyethylene (LDPE) and silicone rubber (SR) samplers for the monitoring of polychlorinated biphenyls (PCBs) in water regarding the uptake, the sampling rate (RS) estimated by using performance reference compounds (PRCs) and the time-weighted average (TWA) concentrations. The second aim is to evaluate the efficiency of these samplers to investigate PCB sources (localization and imputation steps) using methods with and without PRCs to correct for the impact of water velocity on the uptake. Samplers spiked with PRCs were deployed in the outfalls of two PCB sources and at 8 river sites situated upstream and downstream of the outfalls. After 6weeks, the uptake of PCBs in the linear phase was equivalent in LDPE and SR but 5 times lower in LDPE for PCBs approaching equilibrium. PRC-based RS and water velocity (0.08 to 1.21ms-1) were well correlated in river (LDPE: R2=0.91, SR: R2=0.96) but not in outfalls (higher turbulences and potential release of PRCs to air). TWA concentrations obtained with SR were slightly higher than those obtained with LDPE (factor 1.4 to 2.6 in river) likely because of uncertainty in sampler-water partition coefficient values. Concentrations obtained through filtration and extraction of water samples (203L) were 1.6 and 5.1 times higher than TWA concentrations obtained with SR and LDPE samplers, respectively. PCB sources could efficiently be localized when PRCs were used (increases of PCB loads in river) but the impact of high differences of water velocity was overcorrected (leading sometimes to false positives and negatives). Increases of PCB loads in the river could not be entirely imputed to the investigated sources (underestimation of PCBs contributing to the load increases). A method without PRCs (relationship between uptake and water velocity) appeared to be a good complementary method for LDPE.


Assuntos
Monitoramento Ambiental/instrumentação , Bifenilos Policlorados/análise , Rios/química , Poluentes Químicos da Água/análise , Monitoramento Ambiental/métodos , Desenho de Equipamento , Polietileno , Elastômeros de Silicone , Suíça
3.
Anal Bioanal Chem ; 408(4): 1067-78, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26637214

RESUMO

In this work, a method combining polar organic chemical integrative samplers (POCIS) and ultraperformance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) was assessed for the determination of two corrosion inhibitors (benzotriazole and methylbenzotriazole), seven pesticides (atrazine, diuron, isoproturon, linuron, metolachlor, penconazole, terbuthylazine), and four pharmaceuticals (carbamazepine, diclofenac, metformin, sulfamethoxazole) in river water. As a first step, two POCIS sorbents, hydrophilic-lipophilic balance (HLB) and Strata X-CW, were compared. The comparison of the uptake profiles of the studied compounds showed that the HLB sorbent provides better uptake (higher sampled amount and better linearity) than Strata X-CW except for the basic compound metformin. Since the sampling rate (R s) of POCIS depends on environmental factors, seven compounds were evaluated as potential performance reference compounds (PRCs) through kinetic experiments. Deisopropylatrazine-d5 (DIA-d5) and, as far as we know, for the first time 4-methylbenzotriazole-d3 showed suitable desorption. The efficiency of both compounds to correct for the effect of water velocity was shown using a channel system in which POCIS were exposed to 2 and 50 cm s(-1). Finally, POCIS were deployed upstream and downstream of agricultural wine-growing and tree-growing areas in the Lienne River and the Uvrier Canal (Switzerland). The impact of the studied areas on both streams could be demonstrated.

4.
Chemosphere ; 118: 268-76, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25463250

RESUMO

This study aims to provide a passive sampling approach which can be routinely used to investigate polychlorinated biphenyl (PCB) sources in rivers. The approach consists of deploying low density polyethylene (LDPE) strips downstream and upstream of potential PCB sources as well as in their water discharges. Concentrations of indicator PCBs (iPCBs) absorbed in samplers (Cs) from upstream and downstream sites are compared with each other to reveal increases of PCB levels. Cs measured in water discharges are used to determine if released amounts of PCBs are compatible with increases revealed in the river. As water velocity can greatly vary along a river stretch and influences the uptake at each site in a different way, differences in velocity have to be taken into account to correctly interpret Cs. LDPE strips were exposed to velocities between 1.6 and 37 cm s−1 using a channel system built in the field. Relationships between velocity and Cs were established for each iPCB to determine the expected change in Cs due to velocity variations. For PCBs 28 and 52, this change does not exceed a factor 2 for velocity variations in the range from 1.6 to 100 cm s−1 (extrapolated data above 37 cm s−1). For PCBs 101, 138, 153 and 180, this change only exceeds a factor 2 in the case of large velocity variations. The approach was applied in the Swiss river Venoge to first conduct a primary investigation of potential PCB sources and then conduct thorough investigations of two suspected sources.


Assuntos
Monitoramento Ambiental/métodos , Bifenilos Policlorados/análise , Polietileno/química , Rios/química , Poluentes Químicos da Água/análise , Limite de Detecção , Modelos Químicos , Suíça , Água/química
5.
Sci Total Environ ; 499: 319-26, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25201819

RESUMO

One aim of this study is to determine the impact of water velocity on the uptake of indicator polychlorinated biphenyls (iPCBs) by silicone rubber (SR) and low-density polyethylene (LDPE) passive samplers. A second aim is to assess the efficiency of performance reference compounds (PRCs) to correct for the impact of water velocity. SR and LDPE samplers were spiked with 11 or 12 PRCs and exposed for 6 weeks to four different velocities (in the range of 1.6 to 37.7 cm s(-1)) in river-like flow conditions using a channel system supplied with river water. A relationship between velocity and the uptake was found for each iPCB and enables to determine expected changes in the uptake due to velocity variations. For both samplers, velocity increases from 2 to 10 cm s(-1), 30 cm s(-1) (interpolated data) and 100 cm s(-1) (extrapolated data) lead to increases of the uptake which do not exceed a factor of 2, 3 and 4.5, respectively. Results also showed that the influence of velocity decreased with increasing the octanol-water coefficient partition (log K(ow)) of iPCBs when SR is used whereas the opposite effect was observed for LDPE. Time-weighted average (TWA) concentrations of iPCBs in water were calculated from iPCB uptake and PRC release. These calculations were performed using either a single PRC or all the PRCs. The efficiency of PRCs to correct the impact of velocity was assessed by comparing the TWA concentrations obtained at the four tested velocities. For SR, a good agreement was found among the four TWA concentrations with both methods (average RSD<10%). Also for LDPE, PRCs offered a good correction of the impact of water velocity (average RSD of about 10 to 20%). These results contribute to the process of acceptance of passive sampling in routine regulatory monitoring programs.


Assuntos
Monitoramento Ambiental/métodos , Bifenilos Policlorados/análise , Rios/química , Movimentos da Água , Poluentes Químicos da Água/análise , Monitoramento Ambiental/instrumentação , Polietileno/química , Elastômeros de Silicone/química
6.
Chimia (Aarau) ; 68(11): 778-82, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26508484

RESUMO

This study shows the efficiency of passive sampling to reveal industrial and agricultural pollution trends. Two practical applications for nonpolar and polar contaminants are presented. Low-density polyethylene (LDPE) samplers were deployed for one year in the Venoge River (VD) to monitor indicator PCBs (iPCBs, IUPAC nos. 28, 52, 101, 138, 153 and 180). The results showed that the impact of PCB emissions into the river is higher in summer than in other seasons due to the low flow rate of the river during this period. Polar organic chemical integrative samplers (POCIS) were deployed for 4 months in the Sion-Riddes canal (VS) to investigate herbicides (terbuthylazine, diuron and linuron). Desisopropylatrazine-d5 (DIA-d5) was tested as a performance reference compound (PRC) to estimate aqueous concentration. The results showed an increase of water contamination due to the studied agricultural area. The maximal contamination was observed in April and corresponds to the period of herbicide application on the crops.


Assuntos
Monitoramento Ambiental , Poluentes Químicos da Água/análise , Agricultura , Herbicidas , Compostos Orgânicos , Rios , Suíça
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...