Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Physiol Lung Cell Mol Physiol ; 322(1): L129-L148, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34668416

RESUMO

The bronchial epithelium is constantly challenged by inhalative insults including cigarette smoke (CS), a key risk factor for lung disease. In vitro exposure of bronchial epithelial cells using CS extract (CSE) is a widespread alternative to whole CS (wCS) exposure. However, CSE exposure protocols vary considerably between studies, precluding direct comparison of applied doses. Moreover, they are rarely validated in terms of physiological response in vivo and the relevance of the findings is often unclear. We tested six different exposure settings in primary human bronchial epithelial cells (phBECs), including five CSE protocols compared with wCS exposure. We quantified cell-delivered dose and directly compared all exposures using expression analysis of 10 well-established smoke-induced genes in bronchial epithelial cells. CSE exposure of phBECs was varied in terms of differentiation state, exposure route, duration of exposure, and dose. Gene expression was assessed by quantitative real-time PCR (qPCR) and Western Blot analysis. Cell type-specific expression of smoke-induced genes was analyzed by immunofluorescent analysis. Three surprisingly dissimilar exposure types, namely, chronic CSE treatment of differentiating phBECs, acute CSE treatment of submerged basal phBECs, and wCS exposure of differentiated phBECs performed best, resulting in significant upregulation of seven (chronic CSE) and six (acute wCS, acute submerged CSE exposure) out of 10 genes. Acute apical or basolateral exposure of differentiated phBECs with CSE was much less effective despite similar doses used. Our findings provide guidance for the design of human in vitro CS exposure models in experimental and translational lung research.


Assuntos
Brônquios/patologia , Células Epiteliais/patologia , Modelos Biológicos , Fumar/efeitos adversos , Diferenciação Celular , Regulação da Expressão Gênica , Humanos , Reprodutibilidade dos Testes , Fumar/genética
2.
Front Bioeng Biotechnol ; 9: 616830, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33634087

RESUMO

Evolution has endowed the lung with exceptional design providing a large surface area for gas exchange area (ca. 100 m2) in a relatively small tissue volume (ca. 6 L). This is possible due to a complex tissue architecture that has resulted in one of the most challenging organs to be recreated in the lab. The need for realistic and robust in vitro lung models becomes even more evident as causal therapies, especially for chronic respiratory diseases, are lacking. Here, we describe the Cyclic I n VI tro Cell-stretch (CIVIC) "breathing" lung bioreactor for pulmonary epithelial cells at the air-liquid interface (ALI) experiencing cyclic stretch while monitoring stretch-related parameters (amplitude, frequency, and membrane elastic modulus) under real-time conditions. The previously described biomimetic copolymeric BETA membrane (5 µm thick, bioactive, porous, and elastic) was attempted to be improved for even more biomimetic permeability, elasticity (elastic modulus and stretchability), and bioactivity by changing its chemical composition. This biphasic membrane supports both the initial formation of a tight monolayer of pulmonary epithelial cells (A549 and 16HBE14o-) under submerged conditions and the subsequent cell-stretch experiments at the ALI without preconditioning of the membrane. The newly manufactured versions of the BETA membrane did not improve the characteristics of the previously determined optimum BETA membrane (9.35% PCL and 6.34% gelatin [w/v solvent]). Hence, the optimum BETA membrane was used to investigate quantitatively the role of physiologic cyclic mechanical stretch (10% linear stretch; 0.33 Hz: light exercise conditions) on size-dependent cellular uptake and transepithelial transport of nanoparticles (100 nm) and microparticles (1,000 nm) for alveolar epithelial cells (A549) under ALI conditions. Our results show that physiologic stretch enhances cellular uptake of 100 nm nanoparticles across the epithelial cell barrier, but the barrier becomes permeable for both nano- and micron-sized particles (100 and 1,000 nm). This suggests that currently used static in vitro assays may underestimate cellular uptake and transbarrier transport of nanoparticles in the lung.

3.
Biotechnol Bioeng ; 118(2): 690-702, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33058147

RESUMO

We describe the engineering design, computational modeling, and empirical performance of a moving air-liquid interface (MALI) bioreactor for the study of aerosol deposition on cells cultured on an elastic, porous membrane which mimics both air-liquid interface exposure conditions and mechanoelastic motion of lung tissue during breathing. The device consists of two chambers separated by a cell layer cultured on a porous, flexible membrane. The lower (basolateral) chamber is perfused with cell culture medium simulating blood circulation. The upper (apical) chamber representing the air compartment of the lung is interfaced to an aerosol generator and a pressure actuation system. By cycling the pressure in the apical chamber between 0 and 7 kPa, the membrane can mimic the periodic mechanical strain of the alveolar wall. Focusing on the engineering aspects of the system, we show that membrane strain can be monitored by measuring changes in pressure resulting from the movement of media in the basolateral chamber. Moreover, liquid aerosol deposition at a high dose delivery rate (>1 µl cm-2 min-1 ) is highly efficient (ca. 51.5%) and can be accurately modeled using finite element methods. Finally, we show that lung epithelial cells can be mechanically stimulated under air-liquid interface and stretch-conditions without loss of viability. The MALI bioreactor could be used to study the effects of aerosol on alveolar cells cultured at the air-liquid interface in a biodynamic environment or for toxicological or therapeutic applications.


Assuntos
Reatores Biológicos , Células Epiteliais/metabolismo , Modelos Biológicos , Alvéolos Pulmonares/metabolismo , Mecânica Respiratória , Aerossóis , Humanos
4.
Environ Sci Technol ; 41(24): 8406-11, 2007 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-18200871

RESUMO

The chemical composition of ambient aerosol particles affects numerous important aerosol parameters such as their hygroscopicity, optics, and mass as well as their potentially adverse health effects. The objective of this study was to derive both detailed chemical speciation and useful proxies for the quantitative classification of the organic matter (OM) content of carbonaceous aerosol samples. Using three different thermal desorption techniques in an inert atmosphere we investigated eight different carbonaceous particulate matter (PM) samples used for health effect studies: thermal desorption gas chromatography with mass spectrometry, evolved gas analysis with mass spectrometry, and thermogravimetry with Fourier transform infrared spectroscopy. The samples include different types of laboratory-generated particles (pigment black, diffusion flame soot, spark-generated carbon) and two ambient aerosol samples (diesel soot and particulates collected in a road tunnel). All samples showed increasing mass desorption with rising temperature, but no reliable OM classification was possible based on thermal mass desorption alone. In fact, the "organic-free" spark-generated carbon particles showed the second highest mass desorption at 800 degrees C due to the formation of oxygenated structures on unsaturated surface sites and the subsequent evolution of CO and CO2 at elevated temperatures. A quantitative OM classification was accomplished by combining measurements of thermogravimetry and mass spectrometry (up to 800 degrees C) into a novel parameter, the "apparent organic mass fraction". The validity of this classification was confirmed with a second proxy parameter, based only on the evolution of organic components during thermal desorption and information on the generation process of the particles. Both types of pigment blacks (Printex) samples and the spark-generated carbon particles showed the lowest apparent organic mass fraction (< 5%), whereas for road tunnel and diesel emission particles < 16 and < 19% was estimated, respectively.


Assuntos
Poluentes Atmosféricos/análise , Carbono/química , Aerossóis , Cromatografia Gasosa-Espectrometria de Massas , Espectroscopia de Infravermelho com Transformada de Fourier
5.
Anal Bioanal Chem ; 381(2): 508-19, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15657710

RESUMO

Fine and ultrafine particles are probably responsible for numerous health effects, but it is still unclear whether and to what extent the particle itself or organic compounds adsorbed or condensed on the particle are responsible for the effects observed. One important class of particle-bound substances are the polycyclic aromatic hydrocarbons (PAH) and their oxygenated derivatives. To improve the tools used for chemical characterization of particulate matter analytical methods for the determination of PAH and oxygenated PAH in aerosol samples of different origin have been developed and optimized. PAH on high-volume filters and on soot aerosols were analyzed by using accelerated solvent extraction for extraction and high-performance liquid chromatography with fluorescence detection for separation and quantification. Total PAH concentrations were in the range 0.3-9.3 ng m(-3). For analysis of selected oxygenated PAH on high-volume filters a liquid chromatography-tandem mass spectrometric method was developed and optimized. Preliminary investigations showed that oxygenated PAH at pg m(-3) concentrations can be determined.


Assuntos
Aerossóis/química , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Oxigênio/química , Compostos Policíclicos/análise , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...