Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Clin Cancer Res ; 22(20): 5152-5158, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27169996

RESUMO

PURPOSE: Accurate quantification of monoclonal IgM immunoglobulins is essential for response assessment in patients with Waldenström's macroglobulinaemia (WM). The propensity of IgM to form multimers in serum makes sample evaluation by current laboratory methods particularly challenging. EXPERIMENTAL DESIGN: We assessed the precision and linearity of IgMκ and IgMλ heavy/light chain (HLC, Hevylite) assays, and established reference intervals using 120 normal donor sera. We compared the quantitative performance of HLC assays with serum protein electrophoresis (SPE) and total IgM nephelometry for 78 diagnostic samples and follow-up samples from 25 patients with WM. Comparisons were made between the three methods for diagnostic sensitivity and response assessment. RESULTS: IgMκ and IgMλ HLC assays showed low imprecision and good linearity. There was good agreement between summated HLC (IgMκ + IgMλ) and total IgM (measured nephelometrically; R2 = 0.90), but only moderate agreement between involved IgM HLC and SPE densitometry (R2 = 0.49). Analysis of 120 normal donor sera produced the following normal ranges: IgMκ: 0.29-1.82 g/L; IgMλ: 0.17-0.94 g/L; IgMκ/IgMλ ratio: 0.96-2.30. Using these ranges, IgM HLC ratios were abnormal in all WM presentation sera tested, including 15 with non-quantifiable SPE. Despite discordance in quantitation, responses assigned with HLC assays showed excellent agreement to those based on international guidelines using SPE or total IgM; although abnormal HLC ratios indicated residual disease in some patients with negative electrophoresis results. CONCLUSIONS: Nephelometric assessment of IgMκ and IgMλ HLC pairs offers a quantitative alternative to traditional laboratory techniques for the measurement of monoclonal IgM and may aid in the management of WM. Clin Cancer Res; 22(20); 5152-8. ©2016 AACR.


Assuntos
Anticorpos Monoclonais/sangue , Viscosidade Sanguínea/fisiologia , Cadeias Pesadas de Imunoglobulinas/sangue , Cadeias Leves de Imunoglobulina/sangue , Imunoglobulina M/sangue , Macroglobulinemia de Waldenstrom/diagnóstico , Humanos , Nefelometria e Turbidimetria , Macroglobulinemia de Waldenstrom/imunologia
2.
Cancer ; 120(24): 3952-7, 2014 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-25116271

RESUMO

BACKGROUND: Accurate quantification of immunoglobulin A (IgA) monoclonal immunoglobulins by serum protein electrophoresis (SPEP) can be difficult and can impact the assessment of response among patients with multiple myeloma (MM). Therefore, there is a need to identify new assays that better reflect disease burden and response to treatment, and correlate with patient outcome. IgA Hevylite (HLC) measures IgA kappa and IgA lambda separately and provides precise quantitative measurements of the monoclonal IgA expression and polyclonal-isotype matched suppression. In the current study, the authors assessed the usefulness of these assays in the diagnosis of IgA MM and sought to comment on the prognostic value of the assays. METHODS: A study of 157 patients with IgA MM for whom diagnostic samples were available was performed. HLC measurements were performed on a nephelometer and the results were compared with those of electrophoresis. RESULTS: All presentation sera (100 IgA kappa specimens and 57 IgA lambda specimens) were found to have abnormal IgA HLC ratios (IgA kappa median ratio: 336.2 [range, 8.2-7353] and IgA lambda ratio: 0.011 [range, 0.0003-0.45]). In comparison, SPEP bands were quantifiable in only 105 of 157 samples (67%) (median, 28.5 g/L [range, 2.2 g/L-98 g/L]). Of the total of 157 patients, 12 patients (8%) presented with oligosecretory myeloma (<10 g/L; including 4 patients with nonquantifiable SPEP bands). HLC uniquely allows for the measurement of isotype paired suppression, which was found to be associated with shortened overall survival in the current study. CONCLUSIONS: In the current study, IgA HLC ratios were found to be abnormal in all patients and the assay was able to produce quantifiable results in more MM sera than either SPEP or total IgA, potentially representing a solution to the issue of comigration and oligosecretory MM. These preliminary data require confirmation in larger prospective trials to validate the usefulness of IgA HLC.


Assuntos
Imunoglobulina A/sangue , Cadeias Pesadas de Imunoglobulinas/sangue , Cadeias kappa de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/sangue , Mieloma Múltiplo/diagnóstico , Mieloma Múltiplo/terapia , França , Humanos , Imunoglobulina A/química , Cadeias Leves de Imunoglobulina/sangue , Mieloma Múltiplo/sangue , Mieloma Múltiplo/mortalidade , Projetos Piloto , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos
3.
J Alzheimers Dis ; 32(1): 19-22, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22766732

RESUMO

Hexanucleotide expansion repeats in the C9ORF72 gene are a major cause of familial and, to a lesser extent, sporadic frontotemporal lobar degeneration (FTLD), amyotrophic lateral sclerosis (ALS), and FTLD-ALS. To examine whether C9ORF72 expansions could be involved in early-onset Alzheimer's disease (EOAD), we genotyped the hexanucleotide repeat region in a large cohort of 114 EOAD patients who all had positive AD cerebrospinal fluid (CSF) biomarkers. We found hexanucleotide expansion repeats of the C9ORF72 gene in 3 out of 114 patients (2.6%). We raise several hypotheses to explain our results and discuss the current status of AD CSF biomarkers in the dementia diagnostic algorithm.


Assuntos
Doença de Alzheimer/genética , Doença de Alzheimer/psicologia , Demência Frontotemporal/genética , Demência Frontotemporal/psicologia , Proteínas/genética , Idade de Início , Idoso , Doença de Alzheimer/líquido cefalorraquidiano , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Apolipoproteínas E/líquido cefalorraquidiano , Biomarcadores/líquido cefalorraquidiano , Proteína C9orf72 , Estudos de Coortes , Genótipo , Humanos , Repetições de Microssatélites , Pessoa de Meia-Idade , Proteínas tau/líquido cefalorraquidiano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...