Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
JAMA Pediatr ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39008311

RESUMO

Importance: Catheter dislodgement is a common complication for children with tunneled or peripherally inserted noncuffed central venous catheters (CVCs). A subcutaneous anchor securement system (SASS) may reduce this risk compared with traditional adhesive securement. Objective: To compare dislodgement of noncuffed CVCs secured with SASS with dislodgement of noncuffed CVCs secured with sutureless securement devices (SSDs). Design, Setting, and Participants: The SECURED (Securing Central Venous Catheters to Prevent Dislodegment) trial was a pragmatic, multicenter, superiority randomized clinical trial with an internal pilot and was conducted from August 5, 2020, to August 30, 2022, at 2 Australian quaternary pediatric hospitals. Data analysis was performed in January 2023. Patients aged 0 to 18 years requiring a noncuffed CVC (≥3F catheter) were eligible for inclusion. Follow-up duration was 8 weeks or until device removal. Interventions: Patients were randomly assigned 1:1 to receive an SASS or SSD, stratified by hospital and catheter type. Only 1 catheter was studied per patient. Main Outcomes and Measures: The primary outcome was dislodgement (partial or total), defined as movement of the catheter tip by greater than 1 cm (change in external catheter length) at any point during catheter dwell. Dislodgement, reported as a risk ratio (RR), was estimated using a generalized linear model with binomial family and log link. Secondary outcomes were reported as incidence rate ratios and were analyzed using Poission regression. Outcomes reported as mean differences (MDs) were analyzed using linear regression. Results: Of 310 randomized patients, 175 patients (56.5%) were male and median (IQR) patient age was 48 (16-120) months. A total of 307 patients had a catheter device inserted, of which 153 (49.8%) were SASS and 154 (50.2%) were SSD, and were included in the intention-to-treat (ITT) analysis. Device dislodgement was lower with SASS (8 dislodgements in 153 patients [5.2%]) compared with SSD (35 dislodgements in 154 patients [22.7%]) (RR, 0.23; 95% CI, 0.11-0.48; P < .001). The per-protocol analysis was consistent with the ITT analysis. Partial dislodgement accounted for most dislodgement events, including 6 partial dislodgements in the SASS group (3.9%) and 30 partial dislodgements in the SSD group (19.5%) (RR, 0.18; 95% CI, 0.08-0.42). This contributed to fewer complications during dwell in the SASS group (37 reported complications [24.2%]) vs the SSD group (60 reported complications [39.0%]) (RR, 0.62; 95% CI, 0.44-0.87). Staff reported greater difficulty removing devices anchored with SASS vs SSD (mean [SD], 29.1 [31.3] vs 5.3 [17.0], respectively; MD, 23.8; 95% CI, 16.7-31.0). However, use of SASS resulted in reduced per-participant health care costs of A$36.60 (95% credible interval, 4.25-68.95; US $24.36; 95% credible interval, 2.83-45.89). Conclusions and Relevance: In the SECURED trial, noncuffed CVCs secured with SASS had fewer dislodgements compared with SSDs, with a lower cost per patient and an acceptable safety profile. Future efforts should be directed at SASS implementation at the health service level. Trial Registration: anzctr.org.au Identifier: ACTRN12620000783921.

2.
BMJ Open ; 14(7): e084313, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39013653

RESUMO

INTRODUCTION: Peripheral intravenous catheters (PIVCs) are the most commonly used vascular access device in hospitalised patients. Yet PIVCs may be complicated by local or systemic infections leading to increased healthcare costs. Chlorhexidine gluconate (CHG)-impregnated dressings may help reduce PIVC-related infectious complications but have not yet been evaluated. We hypothesise an impregnated CHG transparent dressing, in comparison to standard polyurethane dressing, will be safe, effective and cost-effective in protecting against PIVC-related infectious complications and phlebitis. METHODS AND ANALYSIS: The ProP trial is a multicentre, superiority, randomised clinical and cost-effectiveness trial with internal pilot, conducted across three centres in Australia and France. Patients (adults and children aged ≥6 years) requiring one PIVC for ≥48 hours are eligible. We will exclude patients with emergent PIVCs, known CHG allergy, skin injury at site of insertion or previous trial enrolment. Patients will be randomised to 3M Tegaderm Antimicrobial IV Advanced Securement dressing or standard care group. For the internal pilot, 300 patients will be enrolled to test protocol feasibility (eligibility, recruitment, retention, protocol fidelity, missing data and satisfaction of participants and staff), primary endpoint for internal pilot, assessed by independent data safety monitoring committee. Clinical outcomes will not be reviewed. Following feasibility assessment, the remaining 2624 (1312 per trial arm) patients will be enrolled following the same methods. The primary endpoint is a composite of catheter-related infectious complications and phlebitis. Recruitment began on 3 May 2023. ETHICS AND DISSEMINATION: The protocol was approved by Ouest I ethic committee in France and by The Queensland Children's Hospital Human Research Ethics Committee in Australia. The findings will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT05741866.


Assuntos
Bandagens , Infecções Relacionadas a Cateter , Cateterismo Periférico , Clorexidina , Humanos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Infecções Relacionadas a Cateter/prevenção & controle , Clorexidina/análogos & derivados , Clorexidina/administração & dosagem , Clorexidina/uso terapêutico , Anti-Infecciosos Locais/administração & dosagem , Austrália , Análise Custo-Benefício , Flebite/prevenção & controle , Flebite/etiologia , Criança , França , Adulto
3.
Cochrane Database Syst Rev ; 6: CD013366, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940297

RESUMO

BACKGROUND: Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems. OBJECTIVES: To assess the effectiveness of PICC material and design in reducing catheter failure and complications. SEARCH METHODS: The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information. SELECTION CRITERIA: We included randomised controlled trials (RCTs) evaluating PICC design and materials. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence). AUTHORS' CONCLUSIONS: There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Periférico , Desenho de Equipamento , Falha de Equipamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Tromboembolia Venosa , Humanos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Infecções Relacionadas a Cateter/prevenção & controle , Tromboembolia Venosa/prevenção & controle , Tromboembolia Venosa/etiologia , Obstrução do Cateter , Cateteres Venosos Centrais/efeitos adversos , Causas de Morte , Viés , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Bacteriemia/prevenção & controle , Bacteriemia/etiologia
4.
Expert Opin Pharmacother ; 25(8): 985-997, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38825778

RESUMO

INTRODUCTION: Unfractionated heparin is a widely used anticoagulant in critically ill patients. It has a well-established safety profile and remains an attractive option for clinicians due to its short half-life and reversibility. Heparin has a unique pharmacokinetic profile, which contributes to significant inter-patient and intra-patient variability in effect. The variability in anticoagulant effect combined with heparin's short half-life mean close monitoring is required for clinical efficacy and preventing adverse effects. To optimize heparin use in critically ill patients, effective monitoring assays and dose adjustment strategies are needed. AREAS COVERED: This paper explores the use of heparin as an anticoagulant and optimal approaches to monitoring in critically ill patients. EXPERT OPINION: Conventional monitoring assays for heparin dosing have significant limitations. Emerging data appear to favor using anti-Xa assay monitoring for heparin anticoagulation, which many centers have successfully adopted as the standard. The anti-Xa assay appears have important benefits relative to the aPTT for heparin monitoring in critically ill patients, and should be considered for broader use.


Assuntos
Anticoagulantes , Estado Terminal , Monitoramento de Medicamentos , Heparina , Humanos , Heparina/administração & dosagem , Heparina/farmacocinética , Anticoagulantes/administração & dosagem , Anticoagulantes/farmacocinética , Anticoagulantes/uso terapêutico , Anticoagulantes/efeitos adversos , Monitoramento de Medicamentos/métodos , Relação Dose-Resposta a Droga , Meia-Vida , Guias de Prática Clínica como Assunto , Inibidores do Fator Xa/administração & dosagem , Inibidores do Fator Xa/farmacocinética , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico
6.
Aust Crit Care ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38866692

RESUMO

BACKGROUND: The development of new morbidities has become increasingly identified in paediatric critical care medicine. To date, there has been limited research of long-term outcomes following paediatric critical illness in Australia. OBJECTIVES: The objective of this study was to quantify neurodevelopmental impairments in children following paediatric intensive care unit (PICU) discharge and their association with health-related quality of life (HRQoL). METHODS: A single-centre ambidirectional cohort study at an Australian hospital. Parents of children admitted to the PICU between 2015 and 2017 were invited to participate. Neurodevelopmental outcome and HRQoL was prospectively evaluated, using the Ages and Stages Questionnaire (<5 years), Strengths and Difficulties Questionnaire (≥5 years), and Pediatric Quality of Life Inventory™, respectively. RESULTS: A total of 230 parents of critically ill children participated. Children were 1.9 years old (median, interquartile range [IQR]: 0.2, 7.5), male (59.6%), and ventilated (49.1%) at PICU admission. The median time to follow-up was 24.4 months (IQR: 16.3, 36.7). Parent respondents were more likely to be female (85.5%), White (88.3%), and partnered (81.1%). The incidence of overall neurodevelopmental impairment was 30% (33% in children aged <5 years; 24% in children aged ≥5 years). The incidence of poor HRQoL was 37.9%. History of developmental delay was independently associated with overall neurodevelopmental impairment (adjusted odds ratio [aOR]: 4.21, 95% confidence interval: 2.05, 8.63) and poor HRQoL (aOR: 7.29, 95% confidence interval: 3.26, 16.27). Two or more PICU admissions (aOR: 4.10, IQR: 1.82, 9.26) was also associated with poor HRQoL. CONCLUSIONS: This is the first contemporary view of PICU long-term outcomes conducted in Australia and significantly informs ongoing research in this area. Approximately one-third of PICU survivors demonstrate neurodevelopmental impairment and reduced quality of life. Multiple domains of post-intensive care syndrome-paediatrics must be considered to have a comprehensive understanding of child outcomes. Assessment of baseline/premorbid functioning is also essential in order to understand the true impact of illness and PICU admission.

7.
Cochrane Database Syst Rev ; 5: CD013023, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780138

RESUMO

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Assuntos
Bandagens , Infecções Relacionadas a Cateter , Cateterismo Periférico , Poliuretanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Infecções Relacionadas a Cateter/prevenção & controle , Viés , Falha de Equipamento
8.
JAMA Pediatr ; 178(5): 437-445, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558161

RESUMO

Importance: Peripheral intravenous catheters (PIVCs) facilitate essential treatment. Failure of these essential devices is frequent and new securement strategies may reduce failure and improve patient outcomes. Objective: To evaluate clinical effectiveness of novel PIVC securement technologies for children to reduce catheter failure. Design, Setting, and Participants: A 3-arm, parallel group, superiority randomized clinical trial was conducted at 2 regional Australian hospitals from February 5, 2020, to January 14, 2022. Children aged 6 months to 8 years who were anticipated to require admission with a PIVC for at least 24 hours of in hospital treatment were eligible. Data were analyzed from May 25, 2022, to February 20, 2024. Interventions: Participants were randomly allocated in a 1:1:1 ratio to standard care, bordered polyurethane (Tegaderm [3M]), integrated securement dressing (SorbaView SHIELD [Medline]), and integrated securement dressing with tissue adhesive (Secureport IV). One catheter was studied per patient. Main Outcomes and Measures: Primary outcome was PIVC failure, defined as premature cessation of PIVC function for any reason prior to completion of planned treatment. Secondary outcomes were PIVC complications (any time dislodgement, occlusion, infiltration, partial dislodgement, extravasation, device leaking, phlebitis, pain), PIVC longevity, intervention acceptability (clinicians, participants, caregivers; 0-10 scale), and pain on removal (participants and caregivers; 0-10 scale relevant to age), adverse events, and health care costs. Results: A total of 383 patients (51% female; median age 36 [25th-75th percentiles, 22-72] months) were randomized 134 to standard care, 118 to integrated securement dressing, and 131 to integrated securement dressing with tissue adhesive. PIVC failure was lowest in integrated securement dressing with tissue adhesive (15 [12%]; adjusted hazard ratio [aHR], 0.47; 95% CI, 0.26-0.84) compared with integrated securement dressing (24 [21%]; aHR, 0.78; 95% CI, 0.47-1.28) and standard care (43 [34%]). Direct costs were significantly lower for integrated securement dressing with tissue adhesive (median, Australian dollars [A$], 312 [A$1 is equal to $0.65 US dollars]; IQR, A$302-A$380) and integrated securement dressing (median, A$303; IQR, A$294-A$465) compared with standard care (median, A$341; IQR, A$297-A$592; P ≤ .002) when considering the economic burden related to failure of devices. PIVC longevity and intervention acceptability were similar across all groups. Conclusions and Relevance: In this study, PIVCs secured with integrated securement dressings and tissue adhesive, in comparison with standard care, bordered polyurethane dressings, were associated with significantly reduced PIVC failure, for children admitted to hospital via the emergency department. Further research should focus on implementation in inpatient units where prolonged dwell and reliable intravenous access is most needed. Trial Registration: Australian New Zealand Clinical Trials Registry Identifier: ACTRN12619001026112.


Assuntos
Cateterismo Periférico , Falha de Equipamento , Humanos , Feminino , Masculino , Cateterismo Periférico/métodos , Cateterismo Periférico/instrumentação , Cateterismo Periférico/economia , Criança , Pré-Escolar , Lactente , Bandagens/economia , Austrália , Poliuretanos , Adesivos Teciduais/administração & dosagem
9.
J Intensive Care ; 12(1): 12, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459599

RESUMO

OBJECTIVES: Arterial catheters (ACs) are critical for haemodynamic monitoring and blood sampling but are prone to complications. We investigated the incidence and risk factors of AC failure. METHODS: Secondary analysis of a multi-centre randomised controlled trial (ACTRN 12610000505000). Analysis included a subset of adult intensive care unit patients with an AC. The primary outcome was all-cause device failure. Secondary outcomes were catheter associated bloodstream infection (CABSI), suspected CABSI, occlusion, thrombosis, accidental removal, pain, and line fracture. Risk factors associated with AC failure were investigated using Cox proportional hazards and competing-risk models. RESULTS: Of 664 patients, 173 (26%) experienced AC failure (incidence rate [IR] 37/1000 catheter days). Suspected CABSI was the most common failure type (11%; IR 15.3/1000 catheter days), followed by occlusion (8%; IR 11.9/1,000 catheter days), and accidental removal (4%; IR 5.5/1000 catheter days). CABSI occurred in 16 (2%) patients. All-cause failure and occlusion were reduced with ultrasound-assisted insertion (failure: adjusted hazard ratio [HR] 0.43, 95% CI 0.25, 0.76; occlusion: sub-HR 0.11, 95% CI 0.03, 0.43). Increased age was associated with less AC failure (60-74 years HR 0.63, 95% CI 0.44 to 0.89; 75 + years HR 0.36, 95% CI 0.20, 0.64; referent 15-59 years). Females experienced more occlusion (adjusted sub-HR 2.53, 95% CI 1.49, 4.29), while patients with diabetes had less (SHR 0.15, 95% CI 0.04, 0.63). Suspected CABSI was associated with an abnormal insertion site appearance (SHR 2.71, 95% CI 1.48, 4.99). CONCLUSIONS: AC failure is common with ultrasound-guided insertion associated with lower failure rates. Trial registration Australian New Zealand Clinical Trial Registry (ACTRN 12610000505000); date registered: 18 June 2010.

10.
J Infus Nurs ; 47(2): 75-95, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38422403

RESUMO

Ultrasound-guided insertion of peripheral intravenous catheters (PIVCs) is recommended for patients with difficult intravenous access, but access to ultrasound equipment is often limited to specialty departments. Compact, affordable handheld ultrasound devices are available, but the extent of their clinical adoption and impact on patient outcomes is unknown. This scoping review aimed to explore evidence regarding handheld and pocket ultrasound devices for PIVC insertion. Databases were searched for studies published in English between January 2000 and January 2023 evaluating handheld or pocket ultrasound devices weighing ≤3 kg for PIVC insertion. Data were extracted using standardized forms and summarized using descriptive statistics. Seventeen studies reporting the use of handheld or pocket ultrasound devices were identified. Most studies were conducted in adult inpatient facilities; 3 included pediatrics, and 2 reported out-of-hospital use. Participants with difficult intravenous access featured in 9 studies. Ultrasound training programs were described in 12 studies, with competency defined by number of successful PIVC insertions. Five studies reported clinician and/or patient perspectives. Ultrasound for PIVC insertion is not widely accessible in nonspecialist areas, but more compact and affordable handheld models could provide a solution, especially for patients with difficult access. More research evidence using handheld ultrasound is needed.


Assuntos
Cateterismo , Adulto , Humanos , Criança , Administração Intravenosa , Bases de Dados Factuais
11.
Aust Crit Care ; 37(1): 34-42, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38142148

RESUMO

BACKGROUND: Endotracheal suction is used to maintain endotracheal tube patency. There is limited guidance to inform clinical practice for children with respiratory infections. OBJECTIVE: The objective of this study was to determine whether implementation of a paediatric endotracheal suction appropriate use guideline Paediatric AirWay Suction (PAWS) is associated with an increased use of appropriate and decreased use of inappropriate suction interventions. METHODS: A mixed-method, pre-implementation-post-implementation study was conducted between September 2021 and April 2022. Suction episodes in mechanically ventilated children with a respiratory infection were eligible. Using a structured approach, we implemented the PAWS guideline in a single paediatric intensive care unit. Evaluation included clinical (e.g., suction intervention appropriateness), implementation (e.g., acceptability), and cost outcomes (implementation costs). Associations between implementation of the PAWS guideline and appropriateness of endotracheal suction intervention use were investigated using generalised linear models. RESULTS: Data from 439 eligible suctions were included in the analysis. Following PAWS implementation, inappropriate endotracheal tube intervention use reduced from 99% to 58%, an absolute reduction (AR) of 41% (95% confidence interval [CI]: 25%, 56%). Reductions were most notable for open suction systems (AR: 48%; 95% CI: 30%, 65%), 0.9% sodium chloride use (AR: 23%; 95% CI: 8%, 38%) and presuction and postsuction manual bagging (38%; 95% CI: 16%, 60%, and 86%; 95% CI: 73%, 99%), respectively. Clinicians perceived PAWS as acceptable and suitable for use. CONCLUSIONS: Implementation of endotracheal tube suction appropriate use guidelines in a mixed paediatric intensive care unit was associated with a large reduction in inappropriate suction intervention use in paediatric patients with respiratory infections.


Assuntos
Respiração Artificial , Infecções Respiratórias , Criança , Humanos , Sucção/métodos , Intubação Intratraqueal/efeitos adversos , Cloreto de Sódio
12.
Crit Care Resusc ; 25(1): 33-42, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37876986

RESUMO

Objective: There is a need for evidence on the best sedative agents in children undergoing open heart surgery for congenital heart disease. This study aimed to evaluate the feasibility and safety of dexmedetomidine in this group compared with midazolam. Design: Double blinded, pilot randomized controlled trial. Setting: Cardiac operating theatre and paediatric intensive care unit in Brisbane, Australia. Participants: Infants (≤12 months of age) undergoing their first surgical repair of a congenital heart defect. Interventions: Dexmedetomidine (up to 1.0mcg/kg/hr) versus midazolam (up to 80mcg/kg/hr), commenced in the cardiac operating theatre prior to surgery. Main outcome measures: The primary outcome was the time spent in light sedation (Sedation Behavior Scale [SBS] -1 to +1); Co-primary feasibility outcome was recruitment, retention and protocol adherence. Secondary outcomes were use of supplemental sedatives, ventilator free days, delirium, vasoactive drug support, and adverse events. Neurodevelopment and health-related quality of life (HRQoL) were assessed at 12 months post-surgery. Results: Sixty-six participants were recruited. The number of SBS scores in the light sedation range were greater in the dexmedetomidine group at 24 hours, 48 hours, and overall study duration (0-14 days) versus the midazolam group (24hr: 76/170 [45%] vs 60/178 [34%], aOR 4.14 [95% CI 0.48, 35.92]; 48hr: 154/298 [52%] vs 122/314 [39%], aOR 6.95 [95% CI 0.77, 63.13]; 0-14 days: 597/831 [72%] vs 527/939 [56%], aOR 3.93 [95% CI 0.62, 25.03]). Feasibility was established with no withdrawals or loss to follow-up at 14 days and minimal protocol deviations. There were no differences between the groups relating to clinical, safety, neurodevelopment or HRQoL outcomes. Conclusions: The use of dexmedetomidine was associated with more time spent in light sedation when compared with midazolam. The feasibility of conducting a blinded RCT of midazolam and dexmedetomidine in children undergoing open heart surgery was also established. The findings justify further investigation in a larger trial. Clinical trial registration: ACTRN12615001304527.

13.
JAMA Pediatr ; 177(11): 1132-1140, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37695594

RESUMO

Importance: Peripheral intravenous catheters (PIVCs) frequently fail during treatment causing therapy interruption, pain, recatheterization, and additional health care costs. Midline catheters (MCs) may improve functional dwell time and reduce failure compared with traditional PIVCs. Objective: To compare device failure of MCs with PIVCs. Design, Setting, and Participants: This was a pragmatic, randomized clinical superiority trial with an embedded internal pilot study conducted from July 2020 to May 2022. The study took place in a quaternary pediatric hospital in Brisbane, Queensland, Australia. Inclusion criteria were patients aged 1 to 18 years requiring peripherally compatible intravenous therapy for 4 days or longer. Interventions: Patients were randomly assigned 1:1 to receive a PIVC or MC, stratified by age (≤5 years, >5 years). One catheter was studied per patient. Main Outcomes and Measures: The primary outcome was all-cause device failure, defined as premature cessation of device function. Secondary outcomes included number of insertion attempts, insertion failure, pain (on insertion), procedural time, patient/parent satisfaction (with insertion), device dwell time, device complications during dwell time, additional vascular access devices required to complete treatment, clinician satisfaction (at removal), and health care costs. Results: Of the 128 patients randomly assigned to study groups, 127 patients (median [IQR] age, 7 [2-13] years; 71 male [56%]) had a device inserted, with 65 (51.2%) in the PIVC group and 62 (48.8%) in the MC group. All patients were included in the intention-to-treat analysis. Device failure was lower in patients in the MC group (10 [16.1%]) compared with those in the PIVC group (30 [46.2%]; odds ratio [OR], 0.22; 95% CI, 0.10-0.52; P <.001). MCs were associated with fewer insertion attempts (mean difference [MD], -0.3; 95% CI, -0.5 to 0; P = .04), increased dwell time (MD, 66.9 hours; 95% CI, 36.2-97.5 hours; P <.001), and fewer patients required additional vascular access devices to complete treatment in the MC group (4 [6.5%]) and PIVC group (19 [29.2%]; OR, 0.17; 95% CI, 0.05-0.52; P = .002). Compared with PIVCs, use of MCs was associated with greater patient (9.0 vs 7.1 of 10; P = .002) and parent (9.1 vs 8.2 of 10; P = .02) satisfaction and lower health care costs (AUS -$151.67 [US -$101.13] per person; 95% credible interval, AUS -$171.45 to -$131.90 [US -$114.20 to -$87.95]). Conclusions and Relevance: Findings suggest that MC insertion for patients requiring peripherally compatible intravenous therapy for 4 days or longer should be prioritized to reduce the resource intensive, expensive, and burdensome sequelae of device failure. Trial Registration: Australia New Zealand Clinical Trials Registry, ACTRN12620000724976.


Assuntos
Cateterismo Periférico , Adolescente , Criança , Pré-Escolar , Humanos , Masculino , Austrália , Cateterismo Periférico/efeitos adversos , Catéteres , Falha de Equipamento , Dor/etiologia , Projetos Piloto , Feminino
14.
Br J Nurs ; 32(14): S22-S28, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37495404

RESUMO

Ultrasound-guided insertion of peripheral intravenous catheters (PIVCs) is an alternative to traditional anatomical landmark-based insertion. However, data on its performance in paediatric patients of varying levels of difficult intravenous access are limited. The researchers hypothesise that ultrasound-guided PIVC insertion will increase first-attempt success compared with landmark technique. This randomised, parallel-group, single-centre, superiority trial commenced recruiting in July 2021, including hospitalised children (aged 0 (>37 weeks gestation) to 18 years) requiring a PIVC. It will recruit 180 children, stratified by degree of perceived difficulty, and centrally randomised into two groups (ratio 1:1). The primary outcome is first-attempt PIVC insertion success. Secondary outcomes include total number of PIVC insertion attempts, PIVC insertion failure, post-insertion complications, dwell time, patient/parent satisfaction, and healthcare costs. The current study will inform the superiority of ultrasound-guided PIVC insertion in comparison with landmark technique. Adoption by healthcare facilities might improve patient outcomes and decrease healthcare costs.


Assuntos
Cateterismo Periférico , Remoção de Dispositivo , Criança , Humanos , Cateterismo Periférico/métodos , Falha de Equipamento , Satisfação do Paciente , Ensaios Clínicos Controlados Aleatórios como Assunto , Ultrassonografia , Ultrassonografia de Intervenção , Recém-Nascido , Lactente , Pré-Escolar , Adolescente
15.
BMC Health Serv Res ; 23(1): 587, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37286977

RESUMO

BACKGROUND: Peripheral intravenous catheters (PIVCs) are the most used invasive medical device in healthcare. Yet around half of insertion attempts are unsuccessful leading to delayed medical treatments and patient discomfort of harm. Ultrasound-guided PIVC (USGPIVC) insertion is an evidence-based intervention shown to improve insertion success especially in patients with Difficult IntraVenous Access (BMC Health Serv Res 22:220, 2022), however the implementation in some healthcare settings remains suboptimal. This study aims to co-design interventions that optimise ultrasound guided PIVC insertion in patients with DIVA, implement and evaluate these initiatives and develop scale up activities. METHODS: A stepped-wedge cluster randomized controlled trial will be conducted in three hospitals (two adult, one paediatric) in Queensland, Australia. The intervention will be rolled out across 12 distinct clusters (four per hospital). Intervention development will be guided by Michie's Behavior Change Wheel with the aim to increase local staff capability, opportunity, and motivation for appropriate, sustainable adoption of USGPIVC insertion. Eligible clusters include all wards or departments where > 10 PIVCs/week are typically inserted. All clusters will commence in the control (baseline) phase, then, one cluster per hospital will step up every two months, as feasible, to the implementation phase, where the intervention will be rolled out. Implementation strategies are tailored for each hospital by local investigators and advisory groups, through context assessments, staff surveys, and stakeholder interviews and informed by extensive consumer interviews and consultation. Outcome measures align with the RE-AIM framework including clinical-effectiveness outcomes (e.g., first-time PIVC insertion success for DIVA patients [primary outcome], number of insertion attempts); implementation outcomes (e.g., intervention fidelity, readiness assessment) and cost effectiveness outcomes. The Consolidated Framework for Implementation Research framework will be used to report the intervention as it was implemented; how people participated in and responded to the intervention; contextual influences and how the theory underpinning the intervention was realised and delivered at each site. A sustainability assessment will be undertaken at three- and six-months post intervention. DISCUSSION: Study findings will help define systematic solutions to implement DIVA identification and escalation tools aiming to address consumer dissatisfaction with current PIVC insertion practices. Such actionable knowledge is critical for implementation of scale-up activities. TRIAL REGISTRATION: Prospectively registered (Australian and New Zealand Clinical Trials Registry; ACTRN12621001497897).


Assuntos
Hospitais , Tecnologia , Adulto , Humanos , Criança , Austrália , Queensland , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
16.
Eur J Clin Microbiol Infect Dis ; 42(2): 209-216, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36626086

RESUMO

The epidemiology of Moraxella species bloodstream infection (BSI) is poorly defined due to their rarity. We sought to determine the incidence, risk factors, and outcomes of Moraxella species BSI in a large Australian population. All Moraxella species BSIs in patients admitted to Queensland (population estimate 5 million) public health facilities between 2000 and 2019 and submitted to Queensland pathology laboratory-based surveillance were included. Clinical and hospitalisation data were matched with laboratory-based surveillance data. Incidence rate ratios (IRR) with 95% confidence intervals (CI) were calculated. In total, 375 incident Moraxella species BSI occurred during 86 million person-years of surveillance, with an annualised age and sex standardised incidence of 4.3 per million residents. Isolates were most commonly identified as M. catarrhalis (n = 128; 34%) and community-associated (n = 225; 60%). Incidence was highest in infants, with increasing age associated with lower incidence rate. Males were at higher risk (incidence 2.9 vs. 2.0 per million, IRR1.4; 95% CI, 1.2-1.8), this was most pronounced at age extremes. Two-thirds of adults and 43% of children with Moraxella BSI had at least one comorbid illness. When compared to infections in adults, children were more likely to have community-associated disease, and a head and neck source focus of infection. The all-cause 30-day case-fatality rate was 4% (15/375) and this was significantly higher among adults (14/191; 7% vs 1/183; 1%; p < 0.001). Our findings demonstrate the low burden of Moraxella species BSI in a state-wide cohort, for which young children have the highest risk.


Assuntos
Bacteriemia , Infecção Hospitalar , Sepse , Adulto , Masculino , Criança , Lactente , Humanos , Pré-Escolar , Queensland/epidemiologia , Austrália/epidemiologia , Infecção Hospitalar/microbiologia , Moraxella , Bacteriemia/epidemiologia , Bacteriemia/microbiologia , Incidência
17.
Pediatr Res ; 93(1): 160-167, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35411069

RESUMO

BACKGROUND: Our study aims to explore the experience of having a central venous access device (CVAD) from the perspective of the child and family and how movements within and outside of hospital environments influence this experience. METHODS: A mixed-methods study was conducted across Children's Health Queensland (Australia), including inpatient and home-care settings. Children less than 18 years with CVADs were eligible and followed for 3 months or CVAD removal. A subgroup of primary caregivers participated in semi-structured interviews. Quantitative and qualitative measures of child and family CVAD experiences were explored. RESULTS: In total, 163 patients with 200 CVADs were recruited and followed for 6993 catheter days (3329 [48%] inpatients; 3147 [45%] outpatients; 517 [7%] home). Seventeen participants were interviewed. Experiences of having a CVAD were complex but predominantly positive primarily related to personalized CVAD care, healthcare quality, and general wellbeing. Their experience was shaped by their movements through hospital and home environments, including care variation and distress with procedures. Device selection and insertion location further influenced experience, including safety, impairments in activities of daily living, school, and recreation. CONCLUSIONS: CVAD experiences were influenced by nonmodifiable (e.g., diagnosis) and modifiable factors (e.g., education; care variation). Clinical approaches and policies that account for family and child considerations should be explored. IMPACT: Variation in decision making and management for pediatric CVADs is accepted by many clinicians, but the influence this variation has on the health experience of children and their families is less well explored. This is the first study to draw from a broad range of children requiring CVADs to determine their experience within and outside of healthcare facilities. Interdisciplinary clinicians and researchers need to work collaboratively with children and their families to provide resources and support services to ensure they have positive experiences with CVADs, no matter where they are managed, or who they are managed by.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Serviços de Assistência Domiciliar , Humanos , Criança , Atividades Cotidianas , Austrália , Escolaridade
18.
Aust Crit Care ; 36(4): 509-514, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36038459

RESUMO

OBJECTIVES: We aimed to (i) describe current weaning and extubation practices in children (protocols to identify weaning candidates, spontaneous breathing trials, and other aspects of care such as sedation weaning) and (ii) understand responsibilities for ventilation weaning decisions across Australia and New Zealand (ANZ). METHODS: A cross-sectional survey of ANZ intensive care units who routinely intubate and ventilate children (<18 years) was conducted. We worked with the Australian and New Zealand Intensive Care Society Paediatric Study Group to identify units and potential respondents (senior nurse representative per unit) and to administer questionnaires. Survey questions (n = 35) examined current protocols, practices, unit staffing, and decision-making responsibilities for ventilation weaning and extubation. Open-ended questions examined respondents' experiences of weaning and extubation. RESULTS: A senior nursing respondent from 18/22 intensive care units (82%) completed the survey. Across units, most used sedation assessment tools (88%), and less often, sedation weaning tools (55%). Spontaneous awakening protocols were not used; one unit (5%) reported the use of a spontaneous breathing protocol. Two respondents reported that ventilation weaning protocols (11%) were in use, with 44% of units reporting the use of extubation protocols. Weaning and extubation practices were largely perceived as medically driven, with qualitative data demonstrating a desire from most respondents for greater shared decision-making. CONCLUSION: In ANZ, ventilation weaning and extubation practices are largely medically driven with variation in the use of protocols to support mechanical ventilation weaning and extubation in children. Our findings highlight the importance of future research to determine the impact of greater collaboration of the multidisciplinary team on weaning practices.


Assuntos
Respiração Artificial , Desmame do Respirador , Criança , Humanos , Extubação , Austrália , Estado Terminal , Estudos Transversais , Unidades de Terapia Intensiva , Nova Zelândia , Inquéritos e Questionários
19.
Aust Crit Care ; 36(4): 499-508, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36117039

RESUMO

BACKGROUND/AIM: The objective of this study was to describe current surveillance platforms which support routine quality measurement in paediatric critical care. METHOD: Scoping review. The search strategy consisted of a traditional database and grey literature search as well as expert consultation. Surveillance platforms were eligible for inclusion if they collected measures of quality in critically ill children. RESULTS: The search strategy identified 21 surveillance platforms, collecting 57 unique outcome (70%), process (23%), and structural (7%) quality measures. Hospital-associated infections were the most commonly collected outcome measure across all platforms (n = 11; 52%). In general, case definitions were not harmonised across platforms, with the exception of nationally mandated hospital-associated infections (e.g., central line-associated blood stream infection). Data collection relied on manual coding. Platforms typically did not provide an evidence-based rationale for measures collected, with no identifiable reports of co-designed, consensus-derived measures or consumer involvement in measure selection or prioritisation. CONCLUSIONS: Quality measurement in critically ill children lacks uniformity in definition which limits local and international benchmarking. Current surveillance activities for critically ill children focus heavily on outcome measurement, with process, structural, and patient-reported measures largely overlooked. Long-term outcome measures were not routinely collected. Harmonisation of paediatric intensive care unit quality measures is needed and can be achieved using prioritisation and consensus/co-design methods.


Assuntos
Estado Terminal , Infecção Hospitalar , Criança , Humanos , Cuidados Críticos , Unidades de Terapia Intensiva Pediátrica
20.
Emerg Med Australas ; 34(6): 862-870, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36038953

RESUMO

The optimal approach for peripheral intravenous catheter (PIVC) insertion in adult hospitalised patients with difficult intravenous access (DIVA) is unknown. The present study aimed to critically appraise the quality of (i) assessment instruments and (ii) clinical practice guidelines (CPGs) or escalation pathways for identifying and managing patients with DIVA. Cochrane Central Register of Controlled Trials, EBSCO MEDLINE, EMBASE (OVID) and EBSCO CINAHL databases were searched on 22 March 2021. Studies describing a DIVA assessment measure, CPG or escalation pathway for PIVC insertion in adults (≥18 years of age) were included. Data were extracted using a standardised data extraction form including study design, type of resource and reported clinical outcomes. Quality of DIVA assessment instruments were reviewed using the COnsensus-based Standards for the selection of health Measurement Instruments checklist. Methodological quality of CPGs and escalation pathways was assessed using the Appraisal of Guidelines for Research and Evaluation-II (AGREE-II) instrument. Overall, 24 DIVA resources comprising 16 DIVA assessment instruments and nine CPGs or escalation pathways (including one combined assessment instrument and escalation pathway) were identified. Instruments commonly focused on vein visibility and palpability as indicators of DIVA. CPGs and escalation pathways unanimously recommended use of vessel visualisation technology for patients with or suspected of DIVA. Methodological quality of the resources was mixed. Consensus and standardisation of resources to identify DIVA and recommendations for managing patients with DIVA is limited. Adopting consistent, evidence-based CPGs, escalation pathways or DIVA assessment instruments may significantly improve clinical outcomes.


Assuntos
Cateterismo Periférico , Adulto , Humanos , Administração Intravenosa , Prática Clínica Baseada em Evidências , Lista de Checagem , Catéteres
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...