1.
Phys Med ; 110: 102590, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37116389

RESUMO

PURPOSE: To develop methods for quality assurance of quantitative susceptibility mapping (QSM) using MRI at different magnetic field strengths, and scanners, using different MR-sequence protocols, and post-processing pipelines. METHODS: We built a custom phantom based on iron in two forms: homogeneous susceptibility ('free iron') and with fine-scaled variations in susceptibility ('clustered iron') at different iron concentrations. The phantom was measured at 3.0 T (two scanners), 7.0 T and 9.4 T using multi-echo, gradient echo acquisition sequences. A digital phantom analogue to the iron-phantom, tailored to obtain similar results as in experimentation was developed, with similar geometry and susceptibility values. Morphology enabled dipole inversion was applied to the phase images to obtain QSM for experimental and simulated data using the MEDI + 0 approach for background regularization. RESULTS: Across all scanners, QSM-values showed a linear increase with iron concentrations. The QSM-relaxivity was 0.231 ± 0.047 ppm/mM for free and 0.054 ± 0.013 ppm/mM for clustered iron, with adjusted determination coefficients (DoC) ≥ 0.87. Similarly, the simulations yielded linear increases (DoC ≥ 0.99). In both the experimental and digital phantoms, the estimated molar susceptibility was lower with clustered iron, because clustering led to highly localized field effects. CONCLUSION: Our iron phantom can be used to evaluate the capability of QSM to detect local variations in susceptibility across different field strengths, when using different MR-sequence protocols. The devised simulation method captures the effect of iron clustering in QSM as seen experimentally and could be used in the future to optimize QSM processing pipelines and achieve higher accuracy for local field effects, as also seen in Alzheimer's beta-amyloid plaques.


Assuntos
Ferro , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Encéfalo , Processamento de Imagem Assistida por Computador/métodos , Mapeamento Encefálico/métodos
2.
Magn Reson Med ; 87(5): 2481-2494, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34931721

RESUMO

PURPOSE: To develop fixative agents for high-field MRI with suitable dielectric properties and measure MR properties in immersion-fixed brain tissue. METHODS: Dielectric properties of formalin-based agents were assessed (100 MHz-4.5 GHz), and four candidate fixatives with/without polyvinylpyrrolidone (PVP) and different salt concentrations were formulated. B1 field and MR properties (T1 , R2∗ , R2 , R2' , and magnetic susceptibility [QSM]) were observed in white and gray matter of pig brain samples during 0.5-35 days of immersion fixation. The kinetics were fitted using exponential functions. The immersion time required to reach maximum R2∗ values at different tissue depths was used to estimate the Medawar coefficient for fixative penetration. The effect of replacing the fixatives with Fluoroinert and phosphate-buffered saline as embedding media was also evaluated. RESULTS: The dielectric properties of formalin were nonlinearly modified by increasing amounts of additives. With 5% PVP and 0.04% NaCl, the dielectric properties and B1 field reflected in vivo conditions. The highest B1 values were found in white matter with PVP and varied significantly with tissue depth and embedding media, but not with immersion time. The MR properties depended on PVP yielding lower T1 , higher R2∗ , more paramagnetic QSM values, and a lower Medawar coefficient (0.9 mm/h ; without PVP: 1.5). Regardless of fixative, switching to phosphate-buffered saline as embedder caused a paramagnetic shift in QSM and decreased R2∗ that progressed during 1 month of storage, whereas no differences were found with Fluorinert. CONCLUSION: In vivo-like B1 fields can be achieved in formalin fixatives using PVP and a low salt concentration, yielding lower T1 , higher R2∗ , and more paramagnetic QSM than without additives. The kinetics of R2∗ allowed estimation of fixative tissue penetration.


Assuntos
Formaldeído , Imageamento por Ressonância Magnética , Animais , Encéfalo/diagnóstico por imagem , Fixadores , Neuroimagem , Suínos , Fixação de Tecidos
3.
Sci Rep ; 6: 24151, 2016 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-27063288

RESUMO

Magnetoreception in animals illustrates the interaction of biological systems with the geomagnetic field (geoMF). However, there are few studies that identified the impact of high magnetic field (MF) exposure from Magnetic Resonance Imaging (MRI) scanners (>100,000 times of geoMF) on specific biological targets. Here, we investigated the effects of a 14 Tesla MRI scanner on zebrafish larvae. All zebrafish larvae aligned parallel to the B0 field, i.e. the static MF, in the MRI scanner. The two otoliths (ear stones) in the otic vesicles of zebrafish larvae older than 24 hours post fertilization (hpf) fused together after the high MF exposure as short as 2 hours, yielding a single-otolith phenotype with aberrant swimming behavior. The otolith fusion was blocked in zebrafish larvae under anesthesia or embedded in agarose. Hair cells may play an important role on the MF-induced otolith fusion. This work provided direct evidence to show that high MF interacts with the otic vesicle of zebrafish larvae and causes otolith fusion in an "all-or-none" manner. The MF-induced otolith fusion may facilitate the searching for MF sensors using genetically amenable vertebrate animal models, such as zebrafish.


Assuntos
Campos Magnéticos , Membrana dos Otólitos/efeitos da radiação , Peixe-Zebra/fisiologia , Animais , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Comportamento Animal/efeitos dos fármacos , Comportamento Animal/efeitos da radiação , Embrião não Mamífero/efeitos dos fármacos , Embrião não Mamífero/metabolismo , Embrião não Mamífero/efeitos da radiação , Gentamicinas/toxicidade , Células Ciliadas Auditivas/citologia , Células Ciliadas Auditivas/metabolismo , Larva/efeitos dos fármacos , Larva/fisiologia , Larva/efeitos da radiação , Fígado/patologia , Microscopia Confocal , Microscopia de Vídeo , Membrana dos Otólitos/efeitos dos fármacos , Membrana dos Otólitos/metabolismo , Fenótipo , Peixe-Zebra/crescimento & desenvolvimento