Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Transl Autoimmun ; 4: 100100, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33880442

RESUMO

Impairment of health after overcoming the acute phase of COVID-19 is being observed more and more frequently. Here different symptoms of neurological and/or cardiological origin have been reported. With symptoms, which are very similar to the ones reported but are not caused by SARS-CoV-2, the occurrence of functionally active autoantibodies (fAABs) targeting G-protein coupled receptors (GPCR-fAABs) has been discussed to be involved. We, therefore investigated, whether GPCR-fAABs are detectable in 31 patients suffering from different Long-COVID-19 symptoms after recovery from the acute phase of the disease. The spectrum of symptoms was mostly of neurological origin (29/31 patients), including post-COVID-19 fatigue, alopecia, attention deficit, tremor and others. Combined neurological and cardiovascular disorders were reported in 17 of the 31 patients. Two recovered COVID-19 patients were free of follow-up symptoms. All 31 former COVID-19 patients had between 2 and 7 different GPCR-fAABs that acted as receptor agonists. Some of those GPCR-fAABs activate their target receptors which cause a positive chronotropic effect in neonatal rat cardiomyocytes, the read-out in the test system for their detection (bioassay for GPCR-fAAB detection). Other GPCR-fAABs, in opposite, cause a negative chronotropic effect on those cells. The positive chronotropic GPCR-fAABs identified in the blood of Long-COVID patients targeted the ß2-adrenoceptor (ß2-fAAB), the α1-adrenoceptor (α1-fAAB), the angiotensin II AT1-receptor (AT1-fAAB), and the nociceptin-like opioid receptor (NOC-fAAB). The negative chronotropic GPCR-fAABs identified targeted the muscarinic M2-receptor (M2-fAAB), the MAS-receptor (MAS-fAAB), and the ETA-receptor (ETA-fAAB). It was analysed which of the extracellular receptor loops was targeted by the autoantibodies.

2.
Clin Drug Investig ; 40(5): 433-447, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32222912

RESUMO

BACKGROUND AND OBJECTIVE: BC 007 is a substance with a novel and innovative mode of action for the first-time causal treatment of chronic heart failure, associated with the occurrence of autoantibodies against the ß1-adrenoceptor, and other diseases of mostly the heart and vascular system, being accompanied by the occurrence of functionally active agonistic autoantibodies against G-protein-coupled receptors (fGPCR-AAb). The proposed mechanism of action of BC 007 is the neutralisation of these pathogenic autoantibodies which stimulate the respective receptor. To evaluate the safety, tolerability, pharmacokinetics and mode of action of BC 007, single intravenous infusions of increasing concentration were given to healthy young males and healthy elderly autoantibody-negative and autoantibody-positive participants of both sexes. METHODS: This study was subdivided into three parts. Part A was a single-centre, randomised, double-blind, placebo-controlled safety and tolerability study including healthy young male autoantibody-negative Whites (N = 23) and Asians (N = 1), testing doses of 15, 50 and 150 mg BC 007 (Cohorts 1-3) and elderly male and female Whites (N = 8), testing a dose of 150 mg BC 007 (Cohort 4), randomly assigned in a 3:1 ratio to BC 007 or placebo. Open-label Part B included fGPCR-AAb-positive subjects (50 and 150 mg BC 007, Cohorts 1 and 2, respectively). Open-label Part C included fGPCR-AAb-positive subjects for testing doses of 300, 450, 750, 1350 mg and 1900 mg BC 007. Lower doses were either given as an infusion or divided into a bolus plus infusion up to a dose of 300 mg followed by a constant bolus of 150 mg up to a dose of 750 mg, while at doses of 1350 mg and 1900 mg it was a slow infusion with a constant infusion rate. Infusion times increased with increasing dose from 20 min (15, 50 or 150 mg) to 40 min (300, 450 or 750 mg), 75 min (1350 mg) and 105 min (1900 mg). RESULTS: The mean observed BC 007 area under the concentration-time curve (AUC0-24) increased with increasing dose in a dose proportional manner (slope estimate of 1.039). No serious adverse events were observed. Drug-related adverse events were predominantly the expected mild-to-moderate increase in bleeding time (aPTT), beginning with a dose of 50 mg, which paralleled the infusion and returned to normal shortly after infusion. fGPCR-AAb neutralisation efficiency increased with increasing dose and was achieved for all subjects in the last cohort. CONCLUSION: BC 007 is demonstrated to be safe and well tolerated. BC 007 neutralised fGPCR-AAb, showing a trend for a dose-response relationship in elderly healthy but fGPCR-AAb-positive subjects. CLINICALTRIALS. GOV REGISTRATION NUMBER: NCT02955420.


Assuntos
Autoanticorpos/imunologia , Insuficiência Cardíaca/tratamento farmacológico , Receptores Acoplados a Proteínas G/imunologia , Adulto , Idoso , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Testes de Neutralização , Placebos , Adulto Jovem
3.
Methods Mol Biol ; 1901: 95-102, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30539571

RESUMO

Agonistically acting autoantibodies directed against the adrenergic beta-1 receptor (beta1-AABs) are a pathogenic factor in diseases of the heart and circulatory system such as dilated cardiomyopathy. Here we describe the detection of such functionally active beta1-AABs from serum samples using spontaneously beating neonatal rat cardiomyocytes, which express the fully functional adrenergic beta-1 receptor coupled with the signal transduction pathway that induces chronotropy. With serum samples added (containing beta1-AABs), an increased positive chronotropic effect is caused that can be blocked by the subsequent addition of specific beta-blockers (abolishing this chronotropic response). The return to the basal beat rate of the cells by the addition of a beta-blocker proves the adrenergic beta-1 receptor specificity of the serum sample.


Assuntos
Antagonistas de Receptores Adrenérgicos beta 1/metabolismo , Autoanticorpos/análise , Bioensaio/métodos , Receptores Adrenérgicos beta 1/metabolismo , Animais , Animais Recém-Nascidos , Imunoglobulina G/metabolismo , Ratos
4.
J Pharm Sci ; 107(8): 2033-2041, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29678593

RESUMO

Possible unwanted folding of biopharmaceuticals during manufacturing and storage has resulted in analysis schemes compared to small molecules that include bioanalytical characterization besides chemical characterization. Whether bioanalytical characterization is required for nucleotide-based drugs, may be decided on a case-by-case basis. Nucleotide-based pharmaceuticals, if chemically synthesized, occupy an intermediate position between small-molecule drugs and biologics. Here, we tested whether a physicochemical characterization of a nucleotide-based drug substance, BC 007, was adequate, using circular dichroism (CD) spectroscopy. Nuclear magnetic resonance confirmed CD data in one experimental setup. BC 007 forms a quadruplex structure under specific external conditions, which was characterized for its stability and structural appearance also after denaturation using CD and nuclear magnetic resonance. The amount of the free energy (ΔG0) involved in quadruplex formation of BC 007 was estimated at +8.7 kJ/mol when dissolved in water and +1.4 kJ/mol in 154 mM NaCl, indicating structural instability under these conditions. However, dissolution of the substance in 5 mM of KCl reduced the ΔG0 to -5.6 kJ/mol due to the stabilizing effect of cations. These results show that positive ΔG0 of quadruplex structure formation in water and aqueous NaCl prevents BC 007 from preforming stable 3-dimensional structures, which could potentially affect drug function.


Assuntos
Aptâmeros de Nucleotídeos/química , Preparações Farmacêuticas/química , Dicroísmo Circular/métodos , Estabilidade de Medicamentos , Quadruplex G , Espectroscopia de Ressonância Magnética/métodos , Conformação de Ácido Nucleico , Desnaturação de Ácido Nucleico , Termodinâmica
5.
PLoS One ; 13(2): e0192615, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29425252

RESUMO

Cell-based analytics for the detection of the beta1-adrenoceptor autoantibody (beta1-AAB) are functional, yet difficult to handle, and should be replaced by easily applicable, routine lab methods. Endeavors to develop solid-phase-based assays such as ELISA to exploit epitope moieties for trapping autoantibodies are ongoing. These solid-phase-based assays, however, are often unreliable when used with human patient material, in contrast to animal derived autoantibodies. We therefore tested an immunogen peptide-based ELISA for the detection of beta1-AAB, and compared commercially available goat antibodies against the 2nd extracellular loop of human beta1-adrenoceptor (ADRB1-AB) to autoantibodies enriched from patient material. The functionality of these autoantibodies was tested in a cell based assay for comparison and their structural appearance was investigated using 2D gel electrophoresis. The ELISA showed a limit of detection for ADRB1-AB of about 1.5 nmol antibody/L when spiked in human control serum and only about 25 nmol/L when spiked in species identical (goat) matrix material. When applied to samples of human origin, the ELISA failed to identify the specific beta1-AABs. A low concentration of beta1-AAB, together with structural inconsistency of the patient originated samples as seen from the 2D Gel appearance, might contribute to the failure of the peptide based ELISA technology to detect human beta1-AABs.


Assuntos
Autoanticorpos/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Receptores Adrenérgicos beta 1/imunologia , Animais , Eletroforese em Gel de Poliacrilamida/métodos , Mapeamento de Epitopos , Glicosilação , Cabras , Humanos , Miócitos Cardíacos/imunologia , Ratos , Ratos Wistar
6.
Heliyon ; 3(7): e00362, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28795160

RESUMO

BACKGROUND: Autoantibodies specific for the adrenergic beta1-receptor were identified to be an essential factor for the pathogenesis of dilated cardiomyopathy. For the detection of these autoantibodies, a bioassay was developed and has been used, measuring the positive chronotropic effect on spontaneously beating neonatal rat cardiomyocytes. In order to use this bioassay as an analytical tool to monitor the effectiveness of autoantibody neutralizing therapy in a regulated field, there is a need to assess its analytical performance and validate it according to current guidelines. METHODS: Using standard autoantibody samples, the increased beat rate compared to the basal rate [delta beats/min] was recorded when investigating guideline required assay performance parameters. RESULTS: The analytical specificity and sensitivity of the bioassay was demonstrated. The limit of detection and positivity cut-off level were determined to be 3.56 and 7.97 delta beats/min, respectively. The coefficient of variation (CV) of all tested single values (four technical replicates each) was ≤15.2%. The CV of precision within each measuring series did not exceed 20%. Furthermore, the sample stability under a variety of different storage conditions was assessed, as well as the robustness of the cardiomyocyte preparations, which were both given. CONCLUSION: This bioassay fulfilled guideline determined quality requirements and proved to be appropriate for its application in clinical trials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...