RESUMO
The ITER baseline foresees 2 Heating Neutral Beams (HNB's) based on 1 MeV 40 A D(-) negative ion accelerators, each capable of delivering 16.7 MW of deuterium atoms to the DT plasma, with an optional 3rd HNB injector foreseen as a possible upgrade. In addition, a dedicated diagnostic neutral beam will be injecting ≈22 A of H(0) at 100 keV as the probe beam for charge exchange recombination spectroscopy. The integration of the injectors into the ITER plant is nearly finished necessitating only refinements. A large number of components have passed the final design stage, manufacturing has started, and the essential test beds-for the prototype route chosen-will soon be ready to start.
RESUMO
The ITER equatorial port visible∕infrared wide angle viewing system concept is developed from the measurement requirements. The proposed solution situates 4 viewing systems in the equatorial ports 3, 9, 12, and 17 with 4 views each (looking at the upper target, the inner divertor, and tangentially left and right). This gives sufficient coverage. The spatial resolution of the divertor system is 2 times higher than the other views. For compensation of vacuum-vessel movements, an optical hinge concept is proposed. Compactness and low neutron streaming is achieved by orienting port plug doglegs horizontally. Calibration methods, risks, and R&D topics are outlined.
RESUMO
Recently, plasmas exceeding 4 min have been obtained with lower hybrid current drive (LHCD) in Tore Supra. These LHCD plasmas extend for over 80 times the resistive current diffusion time with zero loop voltage. Under such unique conditions the neoclassical particle pinch driven by the toroidal electric field vanishes. Nevertheless, the density profile remains peaked for more than 4 min. For the first time, the existence of an inward particle pinch in steady-state plasma without toroidal electric field, much larger than the value predicted by the collisional neoclassical theory, is experimentally demonstrated.
RESUMO
Chronic obstructive airway diseases (COAD) can be regarded as one of the major health problems needing environmental actions and screening programs for early detection and intensive patient education programs to cope with the needs of tertiary prevention. On the basis of our epidemiological study focused on COAD carried out in FRG (sample size August 1988: 63,000 participants) a patient education program has been developed and evaluated. In cooperation with general practitioners and pneumologists the program has been installed at practice and community level. The need for a patient education program has been assessed during the three years of the PNEUMOBIL-Project. It is not just a matter of cutting costs, but to a large extent a matter of the wellbeing of the patients and of reducing side effects to a minimum. The objective of the project can be split into three dimensions: (1) The cognitive aspect. Here significant lack of knowledge has to be overcome. At this point it has to be stated clearly that at the present time the medical community is not able to solve this problem on their own. (2) The psychomotoric aspect. Here the competent use of medication has to be trained. (3) The emotional aspect. The patient has to be motivated and integrated into the therapeutic process in a way that his compliance contributes significantly. The didactical concept consists of modules that can be used in varying sequences according to the needs of the target audience.(ABSTRACT TRUNCATED AT 250 WORDS)