Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Sensors (Basel) ; 23(6)2023 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-36991953

RESUMO

When overmoulding optoelectronic devices with optical elements, precise alignment of the overmoulded part and the mould is of great importance. However, mould-integrated positioning sensors and actuators are not yet available as standard components. As a solution, we present a mould-integrated optical coherence tomography (OCT) device that is combined with a piezo-driven mechatronic actuator, which is capable of performing the necessary displacement correction. Because of the complex geometric structure optoelectronic devices may have, a 3D imaging method was preferable, so OCT was chosen. It is shown that the overall concept leads to sufficient alignment accuracy and, apart from compensating for the in-plane position error, provides valuable additional information about the sample both before and after the injection process. The increased alignment accuracy leads to better energy efficiency, improved overall performance and less scrap parts, and thus even a zero-waste production process might be feasible.

2.
BMC Musculoskelet Disord ; 24(1): 51, 2023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-36670400

RESUMO

BACKGROUND: The majority of knee endoprostheses are cemented. In an earlier study the effects of different cementing techniques on cement penetration were evaluated using a Sawbone model. In this study we used a human cadaver model to study the effect of different cementing techniques on relative motion between the implant and the femoral shaft component under dynamic loading. METHODS: Two different cementing techniques were tested in a group of 15 pairs of human fresh frozen legs. In one group a conventional cementation technique was used and, in another group, cementation was done using a pressurizing technique. Under dynamic loading that simulated real life conditions relative motion at the bone-implant interface were studied at 20 degrees and 50 degrees flexion. RESULTS: In both scenarios, the relative motion anterior was significantly increased by pressure application. Distally, it was the same with higher loads. No significant difference could be measured posteriorly at 20°. At 50° flexion, however, pressurization reduced the posterior relative motion significantly at each load level. CONCLUSION: The use of the pressurizer does not improve the overall fixation compared to an adequate manual cement application. The change depends on the loading, flexion angle and varies in its proportion in between the interface zones.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Cimentos Ósseos , Próteses e Implantes
3.
J Knee Surg ; 36(4): 417-423, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34507360

RESUMO

Cemented unicompartmental knee arthroplasty (UKA) shows good survivorship and function. However, implant failure, causing the need for revision, can occur. Aseptic loosening is still among the most common reasons for revision. The purpose of this study was to assess the influence of preimplantation lavage technique on tibial cement penetration depth, tibial cement volume, and load to fracture in the tibial component of mobile-bearing UKA. In 10 pairs of fresh frozen human tibiae, cemented UKA was implanted by an experienced surgeon. Tibial components were then implanted, left and right tibiae were randomly allocated to group A or B. Prior to implantation, irrigation was performed with either syringe lavage or pulsatile jet lavage in a standardized manner. Cement surface was 4170.2 mm2 (3271.6-5497.8 mm2) in the syringe lavage group, whereas the jet lavage group showed 4499.3 mm2 (3354.3-5809.1 mm2); cement volume was significantly higher as well (4143.4 mm3 (2956.6-6198.6 mm3) compared with 5936.9 mm3 (3077.5-8183.1 mm3)). Cement penetration depth was 2.5 mm (1.7-3.2 mm) for the jet lavage, and 1.8 mm (1.2-2.4 mm) for the syringe lavage. The mean fracture load was 4680 N in the jet lavage group and 3800 N in the syringe lavage group (p = 0.001). Subsidence was significantly higher for syringe lavage. This study suggests a correlation of cement penetration depth and cement volume to implant failure in the tibial component of a UKA using a cadaveric model. The type of bone lavage most likely influences these two key parameters.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Cimentos Ósseos , Cadáver , Cimentação/métodos , Irrigação Terapêutica/métodos , Tíbia/cirurgia
5.
J Rehabil Med ; 54: jrm00324, 2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-35929765

RESUMO

OBJECTIVE: To investigate the impact of varus malalignment of the knee on pain reduction achieved by an ankle-foot orthosis and a laterally wedged insole in patients with medial knee osteoarthritis. DESIGN: Secondary analysis of a randomized, clinically prospective cross-over study. PATIENTS: Twenty-eight participants with medial knee osteoarthritis. METHODS: All participants wore a 5-mm laterally wedged insole and an ankle-foot orthosis for a period of 6 weeks each in a randomized order. Pain was reported on a numerical rating scale and was correlated with limb alignment, as defined by the mechanical axis deviation in full-leg standing radiographs. RESULTS: Insole and orthosis use reduced pain compared with baseline (median knee pain change: insole -0.5 (-5 to +6), orthosis -1.5 (-7 to +5). A higher mechanical axis deviation (greater varus) correlated significantly with smaller pain reduction for both aids (insole p = 0.003, orthosis p < 0.001). A cut-off to predict pain response was found at a mechanical axis deviation of 14-15 mm for both aids, i.e. > 3° knee varus. CONCLUSION: There is a correlation between varus malalignment and pain reduction. There seems to be a mechanical axis deviation cut-off that predicts the response to treatment with the aids with good sensitivity.


Assuntos
Órtoses do Pé , Osteoartrite do Joelho , Dor , Tornozelo , Estudos Cross-Over , Humanos , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/terapia , Dor/etiologia , Dor/prevenção & controle , Estudos Prospectivos
6.
Orthopadie (Heidelb) ; 51(12): 1015-1021, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35802155

RESUMO

Treatment of femoral neck fractures secondary to osteopetrosis is an uncertain and puzzled decision. Experience in the treatment, especially in the pediatric population, is scarcely reported. The duration of conservative treatment is prolonged and poses the risks of non-union and development of coxa vara deformity. The recommended treatment is closed reduction and internal fixation; however, surgery on osteopetrotic bone is challenging due to defective bone marrow function, delayed consolidation and higher risk of intraoperative fractures. Slipped capital femoral epiphysis secondary to osteopetrosis is very rarely reported. This article presents the case of a 5-year-old female patient with rapidly deteriorating physical function due to bilateral proximal femoral Salter-Harris type II fractures with associated slippage of the growth plates secondary to confirmed autosomal recessive osteopetrosis. Operative treatment was performed in a tertiary level orthopedic center with closed reduction and internal fixation with cannulated screws. A loss of fixation with coxa vara deformity was seen on the left side 7 months postoperatively with increasing pain. A revision surgery with reosteosynthesis and a valgus osteotomy was thus performed which showed good subjective and objective results 1 year postoperatively with complete bony union.


Assuntos
Coxa Vara , Fraturas do Colo Femoral , Osteopetrose , Escorregamento das Epífises Proximais do Fêmur , Criança , Pré-Escolar , Feminino , Humanos , Coxa Vara/diagnóstico por imagem , Fraturas do Colo Femoral/diagnóstico por imagem , Fixação Interna de Fraturas/métodos , Osteopetrose/complicações , Escorregamento das Epífises Proximais do Fêmur/diagnóstico por imagem
7.
Bone Joint Res ; 11(4): 229-238, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35400170

RESUMO

AIMS: One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. METHODS: A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). RESULTS: The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. CONCLUSION: From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229-238.

8.
Arch Phys Med Rehabil ; 103(9): 1699-1706, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35288097

RESUMO

OBJECTIVE: To investigate the relationship of frontal plane ankle mobility with the effects of an ankle-foot orthosis (AFO) and a laterally wedged insole (LWI) on knee adduction moment (KAM) in the treatment of medial knee osteoarthritis. DESIGN: Randomized, nonblinded crossover trial. SETTING: Outpatient clinic of university hospital. PARTICIPANTS: Referred sample of 20 patients (N=20) with medial knee osteoarthritis stage 1-3 (Kellgren and Lawrence), aged 56.4±6.5 years; 58 patients were assessed, 21 were included, and 1 was a dropout. There were 14 healthy reference participants without knee osteoarthritis (convenience sample) who were matched by age. INTERVENTIONS: Patients received AFO and LWI for 6 weeks each with gait analysis after each 6-week intervention. Patients underwent additional barefoot gait analysis, walking on even ground and on a cross slope of 5° lateral elevation and standing on inclinations of 0°, 5°, 10°, and 20°. MAIN OUTCOME MEASURES: Spearman correlation between the immediate change in first peak of KAM with each aid and the change in hindfoot varus on the cross slope relative to level ground. RESULTS: The KAM reduction with AFO correlated significantly with hindfoot varus reaction to the cross slope during walking: the greater the hindfoot valgization on the cross slope, the greater the KAM reduction with AFO (Spearman ρ=0.53, P=.02). The KAM reduction with LWI correlated moderately negatively with the change in hindfoot varus: the greater the hindfoot valgization on the cross slope, the smaller the KAM reduction with LWI (r=-0.31 P=.18). CONCLUSIONS: LWI may be suitable for patients with limited to normal frontal plane ankle mobility. Patients with greater frontal plane ankle mobility benefit most from frontal plane ankle bridging with AFO. Studies with larger samples are necessary.


Assuntos
Órtoses do Pé , Osteoartrite do Joelho , Tornozelo , Fenômenos Biomecânicos , Marcha , Humanos , Articulação do Joelho , Osteoartrite do Joelho/terapia , Sapatos
9.
Bone Joint Res ; 11(2): 82-90, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35124977

RESUMO

AIMS: The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. METHODS: Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system. RESULTS: At the main fixation zone, the twin peg shows less relative movement at 70°/115°. At the transition zone, relative movements are smaller for the single peg for both angles. The single peg shows higher compression at 70° flexion, whereas the twin peg design shows higher compression at 115°. X-displacement is significantly higher for the single peg at 115°. CONCLUSION: Bony defects should be avoided in OUKA. The twin peg shows high resilience against push-out force and should be preferred over the single peg. Cite this article: Bone Joint Res 2022;11(2):82-90.

10.
Knee ; 33: 185-192, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34638017

RESUMO

BACKGROUND: Aseptic loosening remains one of the most common causes of revision of the tibial component for total knee arthroplasty. A stable bond between implant and cement is essential for appropriate long-term results. The aim of our in vitro study was to investigate the maximum failure load of tibial ATTUNE prosthesis design alternatives compared with a previous design. In addition, cement-in-cement revision was considered as a potential strategy after tibial component debonding. METHODS: The experimental investigations of the maximum failure load of the implant-cement interface were performed under optimal conditions, without potential contamination. We compared the designs of the tibial components of the ATTUNE, ATTUNE S+ and P.F.C. Sigma. In addition, we investigated the cement-in-cement revision for the ATTUNE knee system replacing it with an ATTUNE S+. RESULTS: The maximum failure load showed no significant difference between P.F.C. Sigma and ATTUNE groups (P = 0.087), but there was a significant difference between the P.F.C. Sigma and the ATTUNE S+ groups (P < 0.001). The analysis also showed a significant difference (P < 0.001) between the ATTUNE and the ATTUNE S+ groups for the maximum failure load. The ATTUNE S+ cement-in-cement revision group showed a significant higher failure load (P < 0.001) compared with the P.F.C. Sigma and ATTUNE groups. No significant differences (P = 1.000) were found between the ATTUNE S+ cement-in-cement and ATTUNE S+ group. CONCLUSION: Based on these results, we found no design-specific evidence of increased debonding risk with the ATTUNE and ATTUNE S+ components compared with the P.F.C Sigma. Furthermore, the cement-in-cement revision seems to be an alternative for the revision surgery.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Cimentos Ósseos , Humanos , Articulação do Joelho/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação , Tíbia/cirurgia
11.
Internist (Berl) ; 62(9): 921-927, 2021 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-34328522

RESUMO

Intervertebral disc-related diseases of the cervical and lumbar spine are considered to be occupational diseases, if the occupational and medical prerequisites are fulfilled and the causal connection between the prerequisites is likely. The working conditions include occupational burdens with long-term lifting and carrying of heavy loads or long-term activities in an extremely bent position of the torso, long-term carrying of heavy loads on the shoulders and long-term effects of whole-body vibration in a sitting position. A medical prerequisite is fulfilled by a damage pattern with chronic lower back or neck pain and damage of the cervical or lumbar vertebrae in a conform manner.In the legal assessment the occupational conditions are examined by the preventive services of the statutory accident insurance and the medical conditions by the medical expert. Furthermore, the medical expert examines the causal connection between the fulfilled prerequisites, whereby the temporal connection (reaching the minimum load dose before realization of the conform damage pattern) and by exclusion of other competing factors are essential. As of 1 January 2021 the necessity to quit the burdening occupation has been omitted by law.


Assuntos
Degeneração do Disco Intervertebral , Deslocamento do Disco Intervertebral , Disco Intervertebral , Doenças Profissionais , Vértebras Cervicais , Humanos , Degeneração do Disco Intervertebral/diagnóstico , Deslocamento do Disco Intervertebral/diagnóstico , Doenças Profissionais/diagnóstico , Doenças Profissionais/etiologia
12.
Dtsch Arztebl Int ; 118(13): 227, 2021 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-34090545
13.
Nat Mater ; 20(10): 1407-1413, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112978

RESUMO

Blending organic molecules to tune their energy levels is currently being investigated as an approach to engineer the bulk and interfacial optoelectronic properties of organic semiconductors. It has been proven that the ionization energy and electron affinity can be equally shifted in the same direction by electrostatic effects controlled by blending similar halogenated derivatives with different energetics. Here we show that the energy gap of organic semiconductors can also be tuned by blending. We use oligothiophenes with different numbers of thiophene rings as an example and investigate their structure and electronic properties. Photoelectron spectroscopy and inverse photoelectron spectroscopy show tunability of the single-particle gap, with the optical gaps showing similar, but smaller, effects. Theoretical analysis shows that this tuning is mainly caused by a change in the dielectric constant with blend ratio. Further studies will explore the practical impact of this energy-level engineering strategy for optoelectronic devices.

14.
Knee ; 30: 170-175, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33933907

RESUMO

BACKGROUND: Total knee arthroplasty is a very successful standard treatment for severe osteoarthritis. Nevertheless, the literature reports tibial debonding between implant and bone cement as well as radiolucent lines related to the tibial components of different knee systems. Regardless of cementing techniques and the influences during surgery, we examined the design of a newly developed knee system and its predecessors (Attune, Attune S+, P.F.C. Sigma, P.F.C. Sigma RP/M.B.T., all DePuy). METHODS: We investigated the dimensions of the tibial components and the fit between them and their bone bed after instrumentation in a foam material. RESULTS: Our results showed considerable differences for the used knee prostheses as well as their tibial instrumentation options with a corresponding risk for incomplete seating. CONCLUSION: The orthopedic surgeons need to be aware of these design features and the resulting increased seating resistance especially in hard and sclerotic bone. ARTICLE FOCUS: Comparison of the tibial instruments and the different design options of the Attune knee system and its predecessor knee prostheses. KEY MESSAGES: The Attune implant showed incomplete seating because of too much press fit and an uneven bone quality or sclerosis can result in tilting of the tibial component. STRENGTHS AND LIMITATIONS: This is the first study investigating the Attune knee and its predecessor in terms of implant seating and press fit. The foam material is a limitation.


Assuntos
Artroplastia do Joelho/instrumentação , Cimentos Ósseos , Prótese do Joelho , Tíbia , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Humanos , Articulação do Joelho/cirurgia , Desenho de Prótese , Tíbia/anatomia & histologia , Tíbia/cirurgia
15.
Clin Rehabil ; 35(7): 1032-1043, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33781101

RESUMO

OBJECTIVE: To compare biomechanical and clinical outcome of laterally wedged insoles (LWI) and an ankle-foot orthosis (AFO) in patients with medial knee osteoarthritis. DESIGN: Single-centre, block-randomized, cross-over controlled trial. SETTING: Outpatient clinic. SUBJECTS: About 39 patients with symptomatic medial knee osteoarthritis. INTERVENTIONS: Patients started with either LWI or AFO, determined randomly, and six weeks later changed to the alternative. MAIN MEASURES: Change in the 1st maximum of external knee adduction moment (eKAM) was assessed with gait analysis. Additional outcomes were other kinetic and kinematic changes and the patient-reported outcomes EQ-5D-5L, Oxford Knee Score (OKS), American Knee Society Clinical Rating System (AKSS), Hannover Functional Ability Questionnaire - Osteoarthritis and knee pain. RESULTS: Mean age (SD) of the study population was 58 (8) years, mean BMI 30 (5). Both aids significantly improved OKS (LWI P = 0.003, AFO P = 0.001), AKSS Knee Score (LWI P = 0.01, AFO P = 0.004) and EQ-5D-5L Index (LWI P = 0.001, AFO P = 0.002). AFO reduced the 1st maximum of eKAM by 18% (P < 0.001). The LWI reduced both maxima by 6% (P = 0.02, P = 0.03). Both AFO and LWI reduced the knee adduction angular impulse (KAAI) by 11% (P < 0.001) and 5% (P = 0.05) respectively. The eKAM (1st maximum) and KAAI reduction was significantly larger with AFO than with LWI (P = 0.001, P = 0.004). CONCLUSIONS: AFO reduces medial knee load more than LWI. Nevertheless, no clinical superiority of either of the two aids could be shown.


Assuntos
Órtoses do Pé , Osteoartrite do Joelho/reabilitação , Estudos Cross-Over , Desenho de Equipamento , Feminino , Análise da Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente
16.
J Clin Med ; 9(12)2020 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-33265919

RESUMO

As cerebral palsy (CP) is a complex disorder, classification of gait pathologies is difficult. It is assumed that unclassified patients show less functional impairment and less gait deviation. The aim of this study was to assess the different subgroups and the unclassified patients with unilateral CP using different gait indices. The Gillette Gait Index (GGI), Gait Deviation Index (GDI), Gait Profile Score (GPS) and spatiotemporal parameters derived from instrumented 3D-Gait Analysis (IGA) were assessed. Subgroups were defined using morphological and functional classification systems. Regarding the different gait indices, a ranking of the different gait patterns is evident. Significant differences were found between GMFCS level I and II, Winters et al. (Winters, Gage, Hicks; WGH) type IV and type I and the WGH-unclassified. Concerning the spatiotemporal parameters significant differences were found between GMFCS level I and II concerning velocity. The unclassified patients showed mean values for the different gait indices that were comparable to those of established subgroups. Established gait patterns cause different degrees of gait deviation and functional impairment. The unclassified patients do not differ from established gait patterns but from the unimpaired gait. Further evaluation using 3D-IGA is necessary to identify the underlying gait pathologies of the unclassified patients.

17.
Materials (Basel) ; 13(20)2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-33076447

RESUMO

The medial Oxford unicompartmental knee arthroplasty (OUKA) shows good survivorship, as well as clinical results. Aseptic loosening, however, remains one of the main reasons for revision and polyethylene debris is known to cause aseptic loosening. The role of bearing thickness in total as well as unicondylar knee arthroplasty has been the subject of controversial discussions, especially the longevity of lower thickness bearings in total knee arthroplasty was questioned. The purpose of this study was to assess the influence of bearing thickness on time to revision, damage pattern, penetration, and volumetric material loss. A cohort of 47 consecutively retrieved medial OUKA bearings was analyzed with conventional direct light microscopy applying the Hood damage analysis, as well as measuring the penetration depth. In this retrieval cohort, a difference on survival time, damage, penetration, as well as volumetric material loss could not be seen. We conclude that low as well as high thickness bearings can safely be used in OUKA without any relevant differences in terms of wear and damage.

18.
ACS Appl Mater Interfaces ; 12(36): 40566-40571, 2020 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-32805922

RESUMO

The air sensitivity of n-doped layers is crucial for the long-term stability of organic electronic devices. Although several air-stable and highly efficient n-dopants have been developed, the reason for the varying air sensitivity between different n-doped layers, in which the n-dopant molecules are dispersed, is not fully understood. In contrast to previous studies that compared the air stability of doped films with the energy levels of neat host or dopant layers, we trace back the varying degree of air sensitivity to the energy levels of integer charge transfer states (ICTCs) formed by host anions and dopant cations. Our data indicate a universal limit for the ionization energy of ICTCs above which the n-doped semiconductors are air-stable.

19.
Ther Adv Cardiovasc Dis ; 14: 1753944720926824, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32633682

RESUMO

INTRODUCTION: Current atrial fibrillation (AF) guidelines recommend flecainide as a first-line rhythm control option in patients without structural heart disease. While there is proven efficacy in clinical trials and guideline support, it is hypothesized that flecainide may be underutilized due to negative outcomes in the CAST trial and that adverse effects are less common than previously perceived. METHODS: This retrospective chart review evaluated patients ⩾18 years initiated on flecainide for AF from August 2011 to October 2016 by a cardiology provider at the study site. Exclusion criteria included: <5 days of flecainide therapy, AF due to a reversible cause, and inadequate documentation. The primary outcome was efficacy of flecainide at maintaining symptomatic control at 6 and 12 months. Secondary outcomes included characterization of alterations in rhythm control strategies and documented normal sinus rhythm per electrocardiogram at 6 and 12 months. RESULTS: Of the 326 patients identified, 144 patients were included. After 6 and 12 months, 102 patients (70.8%) and 89 patients (61.8%) of the 144 were symptomatically controlled. Atenolol use (p = 0.024), female sex (p = 0.006), hypertension (p = 0.040), and dronedarone failure (p = 0.012) were associated with flecainide discontinuation at 6 months. At 12 months, only previous propafenone failure (p = 0.032) was significant. Of the 144 patients, 16 (11.1%) reported adverse effects with dizziness, hot flashes, bradycardia, and headache (1.4% each) being the most common. CONCLUSION: Flecainide is a well-tolerated medication, even at 12 months, with very minor adverse effects. These results support the utility of flecainide in guideline recommended patient populations.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Flecainida/uso terapêutico , Frequência Cardíaca/efeitos dos fármacos , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Flecainida/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
20.
Schmerz ; 34(4): 357-368, 2020 08.
Artigo em Alemão | MEDLINE | ID: mdl-32415380

RESUMO

Pain caused by the sacroiliac joint (SIG) makes up a relevant proportion of lumbar back pain and can have a variety of specific and non-specific causes. The SIG represents the central link between the spine and the lower extremity. It is characterized by high stability and low mobility. There are significant inter-individual differences. In addition to the possibility of asymptomatic situations, SIG dysfunction can trigger pain in the lower back with possible radiation to the lower extremity. In addition to a structured medical history, clinical examination requires an examination of the adjacent joints and the neurological status. More specifically, movement and provocation tests as well as infiltrations are carried out. General information and conservative therapeutic methods represent the first-line therapies. Interventional and surgical procedures can help in the case of chronification.


Assuntos
Dor Lombar , Articulação Sacroilíaca , Humanos , Dor Lombar/etiologia , Medição da Dor , Exame Físico , Articulação Sacroilíaca/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...