Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(9): 093517, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182496

RESUMO

K-shell x-ray emission spectroscopy is a standard tool used to diagnose the plasma conditions created in high-energy-density physics experiments. In the simplest approach, the emissivity-weighted average temperature of the plasma can be extracted by fitting an emission spectrum to a single temperature condition. It is known, however, that a range of plasma conditions can contribute to the measured spectra due to a combination of the evolution of the sample and spatial gradients. In this work, we define a parameterized model of the temperature distribution and use Markov Chain Monte Carlo sampling of the input parameters, yielding uncertainties in the fit parameters to assess the uniqueness of the inferred temperature distribution. We present the analysis of time-integrated S and Fe x-ray spectroscopic data from the Orion laser facility and demonstrate that while fitting each spectral region to a single temperature yields two different temperatures, both spectra can be fit simultaneously with a single temperature distribution. We find that fitting both spectral regions together requires a maximum temperature of 1310-70 +90 eV with significant contributions from temperatures down to 200 eV.

2.
Phys Rev E ; 101(3-1): 033205, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32290020

RESUMO

We present direct measurements of electron temperature variations within an inertially confined deuterium-tritium plasma caused by localized mix of higher-Z materials into the central hot spot. The data are derived from newly developed differentially filtered penumbral imaging of the bremsstrahlung continuum emission. Our analysis reveals distinct localized emitting features in the stagnated hot-spot plasma, and we infer spatial variations in the electron temperature: the mixed region is 660±130eV colder than the surrounding hot-spot plasma at 3.26±0.11keV. Our analysis of the energy flow shows that we measure approximately steady-state conditions where the radiative losses in the mix region are balanced by heat conduction from the surrounding hot deuterium-tritium plasma.

3.
Phys Rev E ; 101(2-1): 023204, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32168658

RESUMO

We report measurements of K-shell fluorescence lines induced by fast electrons in ramp-compressed Co targets. The fluorescence emission was stimulated by fast electrons generated through short-pulse laser-solid interaction with an Al target layer. Compression up to 2.1× solid density was achieved while maintaining temperatures well below the Fermi energy, effectively removing the thermal effects from consideration. We observed small but unambiguous redshifts in the Kß fluorescence line relative to unshifted Cu Kα. Redshifts up to 2.6 eV were found to increase with compression and to be consistent with predictions from self-consistent models based on density-functional theory.

4.
Phys Plasmas ; 24(5): 056312, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28611532

RESUMO

For several years, we have been calculating the radiation drive in laser-heated gold hohlraums using flux-limited heat transport with a limiter of 0.15, tabulated values of local thermodynamic equilibrium gold opacity, and an approximate model for not in a local thermodynamic equilibrium (NLTE) gold emissivity (DCA_2010). This model has been successful in predicting the radiation drive in vacuum hohlraums, but for gas-filled hohlraums used to drive capsule implosions, the model consistently predicts too much drive and capsule bang times earlier than measured. In this work, we introduce a new model that brings the calculated bang time into better agreement with the measured bang time. The new model employs (1) a numerical grid that is fully converged in space, energy, and time, (2) a modified approximate NLTE model that includes more physics and is in better agreement with more detailed offline emissivity models, and (3) a reduced flux limiter value of 0.03. We applied this model to gas-filled hohlraum experiments using high density carbon and plastic ablator capsules that had hohlraum He fill gas densities ranging from 0.06 to 1.6 mg/cc and hohlraum diameters of 5.75 or 6.72 mm. The new model predicts bang times to within ±100 ps for most experiments with low to intermediate fill densities (up to 0.85 mg/cc). This model predicts higher temperatures in the plasma than the old model and also predicts that at higher gas fill densities, a significant amount of inner beam laser energy escapes the hohlraum through the opposite laser entrance hole.

5.
Artigo em Inglês | MEDLINE | ID: mdl-32165874

RESUMO

We review the 9th NLTE code comparison workshop, which was held in the Jussieu campus, Paris, from November 30th to December 4th, 2015. This time, the workshop was mainly focused on a systematic investigation of iron NLTE steady-state kinetics and emissivity, over a broad range of temperature and density. Through these comparisons, topics such as modeling of the dielectronic processes, density effects or the effect of an external radiation field were addressed. The K-shell spectroscopy of iron plasmas was also addressed, notably through the interpretation of tokamak and laser experimental spectra.

6.
Rev Sci Instrum ; 87(11): 11E534, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910566

RESUMO

We report on measurements of the electron temperature in the hotspot of inertially confined, layered, spherical implosions on the National Ignition Facility using a differential filtering diagnostic. Measurements of the DT and DD ion temperatures using neutron time-of-flight detectors are complicated by the contribution of hot spot motion to the peak width, which produce an apparent temperature higher than the thermal temperature. The electron temperature is not sensitive to this non-thermal velocity and is thus a valuable input to interpreting the stagnated hot spot conditions. Here we show that the current differential filtering diagnostic provides insufficient temperature resolution for the hot spot temperatures of interest. We then propose a new differential filter configuration utilizing larger pinhole size to increase spectral fluence, as well as thicker filtration. This new configuration will improve measurement uncertainty by more than a factor of three, allowing for a more accurate hotspot temperature.

7.
Rev Sci Instrum ; 87(11): 11E327, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910341

RESUMO

The electron temperature at stagnation of an ICF implosion can be measured from the emission spectrum of high-energy x-rays that pass through the cold material surrounding the hot stagnating core. Here we describe a platform developed on the National Ignition Facility where trace levels of a mid-Z dopant (krypton) are added to the fuel gas of a symcap (symmetry surrogate) implosion to allow for the use of x-ray spectroscopy of the krypton line emission.

8.
Rev Sci Instrum ; 87(11): 11E344, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910374

RESUMO

A high resolution (E/ΔE = 1200-1800) Bragg crystal x-ray spectrometer is being developed to measure plasma parameters in National Ignition Facility experiments. The instrument will be a diagnostic instrument manipulator positioned cassette designed mainly to infer electron density in compressed capsules from Stark broadening of the helium-ß (1s2-1s3p) lines of krypton and electron temperature from the relative intensities of dielectronic satellites. Two conically shaped crystals will diffract and focus (1) the Kr Heß complex and (2) the Heα (1s2-1s2p) and Lyα (1s-2p) complexes onto a streak camera photocathode for time resolved measurement, and a third cylindrical or conical crystal will focus the full Heα to Heß spectral range onto an image plate to provide a time integrated calibration spectrum. Calculations of source x-ray intensity, spectrometer throughput, and spectral resolution are presented. Details of the conical-crystal focusing properties as well as the status of the instrumental design are also presented.

9.
Phys Rev Lett ; 117(3): 035001, 2016 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-27472117

RESUMO

First measurements of hydrodynamic growth near peak implosion velocity in an inertial confinement fusion (ICF) implosion at the National Ignition Facility were obtained using a self-radiographing technique and a preimposed Legendre mode 40, λ=140 µm, sinusoidal perturbation. These are the first measurements of the total growth at the most unstable mode from acceleration Rayleigh-Taylor achieved in any ICF experiment to date, showing growth of the areal density perturbation of ∼7000×. Measurements were made at convergences of ∼5 to ∼10× at both the waist and pole of the capsule, demonstrating simultaneous measurements of the growth factors from both lines of sight. The areal density growth factors are an order of magnitude larger than prior experimental measurements and differed by ∼2× between the waist and the pole, showing asymmetry in the measured growth factors. These new measurements significantly advance our ability to diagnose perturbations detrimental to ICF implosions, uniquely intersecting the change from an accelerating to decelerating shell, with multiple simultaneous angular views.

10.
Allergy ; 71(7): 1037-47, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27007085

RESUMO

BACKGROUND: Both systemic inflammation and sex hormones have been proposed as potential mediators of the obese-asthma phenotype. The aim of this study was to examine the associations between sex hormones, oral contraceptive pill (OCP) use, systemic inflammation and airway inflammation in adults with asthma. METHODS: Obese (n = 39) and nonobese (n = 42) females and obese (n = 24) and nonobese (n = 25) males with asthma were recruited. Females were further categorized as reproductive-aged (<50 years old; n = 36) or older (>50 years old; n = 45). Thirteen (36.1%) reproductive-aged females were using the OCP. Participants had induced sputum cell counts measured and blood analysed for sex hormones and inflammatory markers. RESULTS: Obese reproductive-aged females had higher sputum %neutrophils than nonobese reproductive-aged females (45.4 ± 24.3% vs 27.5 ± 17.5%, P = 0.016); however, there was no difference in sputum neutrophils in obese compared with nonobese males (P = 0.620) or older females (P = 0.087). Multiple linear regression analysis found testosterone and OCP use to be negative predictors of sputum %neutrophils, while C-reactive protein and IL-6 were positive predictors of sputum %neutrophils. BMI and age were not significant predictors in the multivariate model. Reproductive-aged females using the OCP had significantly lower sputum %neutrophils than those not using the OCP (23.2 ± 12.6% vs 42.1 ± 23.8%, P = 0.015). CONCLUSIONS: This study suggests that sex hormones and systemic inflammation may be mediating the obese-asthma phenotype. The observation that OCP use was associated with lower sputum %neutrophils in reproductive-aged females warrants further investigation.


Assuntos
Asma/etiologia , Asma/metabolismo , Hormônios Esteroides Gonadais/metabolismo , Inflamação/complicações , Inflamação/metabolismo , Obesidade/complicações , Obesidade/metabolismo , Fenótipo , Adulto , Idoso , Asma/epidemiologia , Biomarcadores , Anticoncepcionais Orais/efeitos adversos , Feminino , Humanos , Mediadores da Inflamação/metabolismo , Masculino , Pessoa de Meia-Idade , Neutrófilos/imunologia , Neutrófilos/metabolismo , Testes de Função Respiratória , Escarro/citologia
11.
Phys Rev Lett ; 112(14): 145004, 2014 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-24765979

RESUMO

Detailed measurements of the electron densities, temperatures, and ionization states of compressed CH shells approaching pressures of 50 Mbar are achieved with spectrally resolved x-ray scattering. Laser-produced 9 keV x-rays probe the plasma during the transient state of three-shock coalescence. High signal-to-noise x-ray scattering spectra show direct evidence of continuum depression in highly degenerate warm dense matter states with electron densities ne>1024 cm-3. The measured densities and temperatures agree well with radiation-hydrodynamic modeling when accounting for continuum lowering in calculations that employ detailed configuration accounting.

12.
Phys Rev Lett ; 111(4): 045001, 2013 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-23931375

RESUMO

Mixing of plastic ablator material, doped with Cu and Ge dopants, deep into the hot spot of ignition-scale inertial confinement fusion implosions by hydrodynamic instabilities is diagnosed with x-ray spectroscopy on the National Ignition Facility. The amount of hot-spot mix mass is determined from the absolute brightness of the emergent Cu and Ge K-shell emission. The Cu and Ge dopants placed at different radial locations in the plastic ablator show the ablation-front hydrodynamic instability is primarily responsible for hot-spot mix. Low neutron yields and hot-spot mix mass between 34(-13,+50) ng and 4000(-2970,+17 160) ng are observed.

13.
Clin Exp Allergy ; 43(1): 36-49, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23278879

RESUMO

BACKGROUND: Obesity and asthma are associated conditions; however, the mechanisms linking the two remain unclear. Few studies have examined the effects of weight loss on inflammation and clinical outcomes in obese-asthma. OBJECTIVE: To compare the effects of weight loss achieved by dietary restriction, exercise or combined dietary restriction and exercise on airway inflammation and clinical outcomes in overweight and obese adults with asthma. METHODS: Participants (n = 46; 54.3% female, body mass index (mean ± SD) 33.7 ± 3.5 kg/m(2) ) were randomized to complete a 10-week dietary, exercise or combined dietary and exercise intervention. Dual-energy x-ray absorptiometry was performed, the Juniper Asthma Control Questionnaire and Juniper Asthma Quality of Life Questionnaire completed and inflammatory markers, dietary intake and physical activity measured. The trial was registered with the Australian Clinical Trials Registry: ACTRN12611000235909. RESULTS: Retention was 82.6%. Mean ± SD weight loss was 8.5 ± 4.2%, 1.8 ± 2.6% and 8.3 ± 4.9% after the dietary, exercise and combined interventions respectively. Asthma control improved after the dietary (mean ± SD; -0.6 ± 0.5, P ≤ 0.001) and combined interventions (-0.5 ± 0.7, P = 0.040), whereas quality of life improved after the dietary [median (IQR); 0.9 (0.4, 1.3), P = 0.002], exercise [0.49 (0.03, 0.78), P = 0.037] and combined [0.5 (0.1, 1.0), P = 0.007] interventions. A 5-10% weight loss resulted in clinically important improvements to asthma control in 58%, and quality of life in 83%, of subjects. Gynoid adipose tissue reduction was associated with reduced neutrophilic airway inflammation in women [ß-coefficient (95% CI); 1.75 (0.02, 3.48), P = 0.047], whereas a reduction in dietary saturated fat was associated with reduced neutrophilic airway inflammation in males (r = 0.775, P = 0.041). The exercise intervention resulted in a significant reduction to sputum eosinophils [median (IQR); -1.3 (-2.0, -1.0)%, P = 0.028]. CONCLUSION AND CLINICAL RELEVANCE: This study suggests a weight-loss goal of 5-10% be recommended to assist in the clinical management of overweight and obese adults with asthma. The obese-asthma phenotype may involve both innate and allergic inflammatory pathways.


Assuntos
Asma/terapia , Dieta Redutora/métodos , Terapia por Exercício/métodos , Obesidade/terapia , Asma/etiologia , Proteína C-Reativa/análise , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Sobrepeso/complicações , Sobrepeso/terapia , Pneumonia/terapia , Testes de Função Respiratória , Redução de Peso
14.
Rev Sci Instrum ; 83(10): 10E127, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126948

RESUMO

Future implosion experiments at the national ignition facility (NIF) will endeavor to simultaneously measure electron and ion temperatures with temporal and spatial resolution in order to explore non-equilibrium temperature distributions and their relaxation toward equilibrium. In anticipation of these experiments, and with understanding of the constraints of the NIF facility environment, we have explored the use of Doppler broadening of mid-Z dopant emission lines, such as krypton He-α at 13 keV, as a diagnostic of time- and potentially space-resolved ion temperature. We have investigated a number of options analytically and with numerical raytracing, and we have identified several promising candidate spectrometer designs that meet the expected requirements of spectral and temporal resolution and data signal-to-noise ratio for gas-filled exploding pusher implosions, while providing maximum flexibility for use on a variety of experiments that potentially include burning plasma.

15.
Rev Sci Instrum ; 83(10): 10E138, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126959

RESUMO

The volumetric heating of a thin copper target has been studied with time resolved x-ray spectroscopy. The copper target was heated by a plasma produced using the Lawrence Livermore National Laboratory's Compact Multipulse Terawatt (COMET) laser. A variable spaced grating spectrometer coupled to an x-ray streak camera measured soft x-ray emission (800-1550 eV) from the back of the copper target to characterize the bulk heating of the target. Radiation hydrodynamic simulations were modeled in two-dimensions using the HYDRA code. The target conditions calculated by HYDRA were post-processed with the atomic kinetics code CRETIN to generate synthetic emission spectra. A comparison between the experimental and simulated spectra indicates the presence of specific ionization states of copper and the corresponding electron temperatures and ion densities throughout the laser-heated copper target.

16.
Eur Respir J ; 38(3): 594-602, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21310876

RESUMO

Obesity and asthma are associated, but the mechanism(s) of the association have yet to be elucidated. The aim of this study was to assess airway inflammation in relation to obesity and plasma fatty acids in males and females with and without asthma. Obese (n=68) and nonobese (n=47) adults with asthma, and obese (n=16) and nonobese (n=63) healthy controls had induced sputum and venous blood samples analysed for inflammatory markers. There was a positive interaction between obesity and asthma on sputum neutrophil percentage (p=0.012) and C-reactive protein level (p=0.003). Although sputum eosinophil percentage was elevated in asthma (p=0.001), there was no effect of obesity (p=0.16). Sputum neutrophil percentage was positively associated with body mass index in females with asthma (ß=1.015, 95% CI 0.258-1.772; p=0.009) and neutrophilic asthma was present in a greater proportion of obese compared with non-obese females (42.9% versus 16.2%; p=0.017). In males with asthma, sputum neutrophil percentage was positively associated with total plasma saturated fatty acids (ß=0.108, 95% CI 0.036-0.180; p=0.004) and negatively with monounsaturated fatty acids (ß= -0.068, 95% CI -0.131- -0.005; p=0.035). This was the first study to demonstrate an increase in neutrophilic airway inflammation in obese asthma. This relationship was significant only in females with asthma. In males, saturated and monounsaturated fatty acids were important predictors of neutrophilic airway inflammation in asthma.


Assuntos
Asma/patologia , Brônquios/patologia , Ácidos Graxos/metabolismo , Inflamação/patologia , Obesidade/patologia , Adulto , Idoso , Asma/sangue , Asma/complicações , Índice de Massa Corporal , Proteína C-Reativa/metabolismo , Sobrevivência Celular , Ácidos Graxos/sangue , Feminino , Humanos , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Neutrófilos/metabolismo , Obesidade/complicações , Análise de Regressão , Espirometria/métodos
17.
Neuroscience ; 162(4): 1055-71, 2009 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-19328838

RESUMO

The neurotransmitter glutamate is inactivated by cellular uptake; mostly catalyzed by the glutamate transporter GLT1 (slc1a2, excitatory amino acid transporter [EAAT2]) subtype which is expressed at high levels in brain astrocytes and at lower levels in neurons. Three coulombs-terminal variants of GLT1 exist (GLT1a, GLT1b and GLT1c). Their cellular distributions are currently being debated (that of GLT1b in particular). Here we have made antibodies to the variants and produced pure preparations of the individual variant proteins. The immunoreactivities of each variant per amount of protein were compared to that of total GLT1 immunoisolated from Wistar rat brains. At eight weeks of age GLT1a, GLT1b and GLT1c represented, respectively 90%+/-1%, 6+/-1% and 1%+/-0.5% (mean+/-SEM) of total hippocampal GLT1. The levels of all three variants were low at birth and increased towards adulthood, but GLT1a increased relatively more than the other two. At postnatal day 14 the levels of GLT1b and GLT1c relative to total GLT1 were, respectively, 1.7+/-0.1 and 2.5+/-0.1 times higher than at eight weeks. In tissue sections, antibodies to GLT1a gave stronger labeling than antibodies to GLT1b, but the distributions of GLT1a and GLT1b were similar in that both were predominantly expressed in astroglia, cell bodies as well as their finest ramifications. GLT1b was not detected in nerve terminals in normal brain tissue. The findings illustrate the need for quantitative measurements and support the notion that the importance of the variants may not be due to the transporter molecules themselves, but rather that their expression represents the activities of different regulatory pathways.


Assuntos
Encéfalo/metabolismo , Transportador 2 de Aminoácido Excitatório/metabolismo , Processamento Alternativo , Animais , Anticorpos , Transportador 2 de Aminoácido Excitatório/genética , Transportador 2 de Aminoácido Excitatório/imunologia , Regulação da Expressão Gênica , Immunoblotting , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia Eletrônica , Isoformas de Proteínas/genética , Isoformas de Proteínas/imunologia , Isoformas de Proteínas/metabolismo , Coelhos , Ratos , Especificidade da Espécie , Fatores de Tempo
18.
Phys Rev E Stat Nonlin Soft Matter Phys ; 77(2 Pt 2): 026404, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18352130

RESUMO

The interaction of 32.5 and 6 nm ultrashort x-ray pulses with the solid materials B4C , SiC, and Si is simulated with a nonlocal thermodynamic equilibrium radiation transfer code. We study the ionization dynamics as a function of depth in the material and modifications of the opacity during irradiation, and estimate the crater depth. Furthermore, we compare the estimated crater depth with experimental data, for fluences up to 2.2 J/cm2. Our results show that, at 32.5 nm irradiation, the opacity changes by less than a factor of 2 for B4C and Si and by a factor of 3 for SiC, for fluences up to 200 J/cm2. At a laser wavelength of 6 nm, the model predicts a dramatic decrease in opacity due to the weak inverse bremsstrahlung, increasing the crater depth for high fluences.

19.
Phys Rev Lett ; 96(18): 185002, 2006 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-16712368

RESUMO

Experimental x-ray spectra of the H-like 2p --> 1s (Lyman-alpha) doublet have been obtained using time-integrated high-resolution spectroscopy of a constrained-flow, laser-generated aluminum plasma. These spectra show monotonic alteration of the relative intensities of the doublet components with distance from the target surface. Excellent agreement between experiment and theory is found only if the modeling includes both ion collisional rates between the fine-structure components of the level and, more importantly, the radiative pumping of one Lyman-alpha component by the other component along the direction of the major velocity gradient (i.e., perpendicular to the direction of spectra observation). Understanding radiation transfer in plasmas with high velocity gradients is important in modeling many astrophysical objects, and this experiment acts as a benchmark for such complex calculations.

20.
Phys Rev E Stat Nonlin Soft Matter Phys ; 66(6 Pt 2): 066413, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12513418

RESUMO

Both the theoretical basis and the computational approach for extending the capabilities of an established spectral line broadening code are presented. By following standard line broadening theory, the effects of an external magnetic field are incorporated into the plasma average and atomic Hamiltonian. An external magnetic field introduces a preferential axis that destroys the symmetry of the quasistatic electric ion microfield. An external magnetic field also modifies the angular properties of the atomic Hamiltonian-atomic energy levels are perturbed and the spectral emission line is polarized. These extensions have been incorporated in an atomic line shape code for complex atoms and applied to several problems of importance to the understanding of tokamak edge plasmas. Applications fall into two broad categories: (1) determination of local plasma properties, such as the magnetic field strength, from distinct line shape features; and (2) consideration of global plasma phenomenon, such as radiation transport. Observable features of the Zeeman effect make H(alpha) a good line for diagnosing the magnetic field. H(beta) does not make a good electron density diagnostic since the Zeeman effect is comparable to the Stark effect for a majority of tokamak edge plasma conditions. For optically thick lines, the details of the spectral line shapes are shown to significantly influence the transport of radiation throughout the system.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...