1.
Rev Sci Instrum ; 85(2): 023701, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593365

RESUMO

A novel sample mount design with integrated fiducial marks and software for assisting operators in easily and efficiently locating points of interest established in previous analytical sessions is described. The sample holder and software were evaluated with experiments to demonstrate the utility and ease of finding the same points of interest in two different microscopy instruments. Also, numerical analysis of expected errors in determining the same position with errors unbiased by a human operator was performed. Based on the results, issues related to acquiring reproducibility and best practices for using the sample mount and software were identified. Overall, the sample mount methodology allows data to be efficiently and easily collected on different instruments for the same sample location.

2.
Appl Opt ; 51(7): B155-64, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22410914

RESUMO

Automated interpretation of laser-induced breakdown spectroscopy (LIBS) data is necessary due to the plethora of spectra that can be acquired in a relatively short time. However, traditional chemometric and artificial neural network methods that have been employed are not always transparent to a skilled user. A fuzzy logic approach to data interpretation has now been adapted to LIBS spectral interpretation. Fuzzy logic inference rules were developed using methodology that includes data mining methods and operator expertise to differentiate between various copper-containing and stainless steel alloys as well as unknowns. Results using the fuzzy logic inference engine indicate a high degree of confidence in spectral assignment.


Assuntos
Lógica Fuzzy , Lasers , Processamento de Sinais Assistido por Computador , Análise Espectral/métodos , Algoritmos , Cobre/análise , Mineração de Dados , Redes Neurais de Computação , Aço Inoxidável/análise
3.
Appl Opt ; 51(7): B165-70, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22410915

RESUMO

A Fabry-Perot etalon was coupled to a Czerny-Turner spectrometer to acquire high-resolution measurements in laser-induced breakdown spectroscopy (LIBS). The spectrometer was built using an inexpensive etalon coupled to a standard 0.5 m imaging spectrometer. The Hg emission doublet at 313.2 nm was used to evaluate instrument performance because it has a splitting of 29 pm. The 313.2 nm doublet was chosen due to the similar splitting seen in isotope splitting from uranium at 424.437 nm, which is 25 pm. The Hg doublet was easily resolved from a continuous-source Hg lamp with a 2 s acquisition. The doublet was also resolved in LIBS spectra of cinnabar (HgS) from the accumulation of 600 laser shots at rate of 10 Hz, or 1 min, under a helium atmosphere. In addition to the observed splitting of the 313.2 nm Hg doublet, the FWHM of the 313.1844 nm line from the doublet is reported at varying helium atmospheric pressures. The high performance, low cost, and compact footprint make this system highly competitive with 2 m double-pass Czerny-Turner spectrometers.

4.
Anal Chim Acta ; 697(1-2): 38-47, 2011 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-21641417

RESUMO

Recovery of chemical contaminants from fixed surfaces for analysis can be challenging, particularly if it is not possible to acquire a solid sample to be taken to the laboratory. A simple device is described that collects semi-volatile organic compounds from fixed surfaces by creating an enclosed volume over the surface, then generating a modest vacuum. A solid-phase microextraction (SPME) fiber is then inserted into the evacuated volume where it functions to sorb volatilized organic contaminants. The device is based on a syringe modified with a seal that is used to create the vacuum, with a perforable plunger through which the SPME fiber is inserted. The reduced pressure speeds partitioning of the semi-volatile compounds into the gas phase and reduces the boundary layer around the SPME fiber, which enables a fraction of the volatilized organics to partition into the SPME fiber. After sample collection, the SPME fiber is analyzed using conventional gas chromatography/mass spectrometry. The methodology has been used to collect organophosphorus compounds from glass surfaces, to provide a simple test for the functionality of the devices. Thirty minute sampling times (ΔT(vac)) resulted in fractional recovery efficiencies that ranged from 10(-3) to >10(-2), and in absolute terms, collection of low nanograms was demonstrated. Fractional recovery values were positively correlated to the vapor pressure of the compounds being sampled. Fractional recovery also increased with increasing ΔT(vac) and displayed a roughly logarithmic profile, indicating that an operational equilibrium is being approached. Fractional recovery decreased with increasing time between exposure and sampling; however, recordable quantities of the phosphonates could be collected three weeks after exposure.

5.
Anal Bioanal Chem ; 400(10): 3217-27, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21553217

RESUMO

Double-pulse laser-induced breakdown spectroscopy (DP-LIBS) has been shown to enhance LIBS spectra. Several researchers have reported significant increases in signal-to-noise and/or spectral intensity compared to single-pulse (SP) LIBS. In addition to DP-LIBS, atmospheric conditions can also increase sensitivity. Thus, in this study, a collinear DP-LIBS scheme was used along with manipulation of the atmospheric conditions. The DP-LIBS scheme consisted of an initial 45-mJ pulse at 1,064-nm fired into a sample contained in a controlled atmospheric/vacuum chamber. A second analytical 45-mJ pulse at 1,064-nm was then fired 0 to 200 µs after and along the same path of the first pulse. Ar, He, and air at pressures ranging from atmospheric pressure to 1 Torr are introduced during DP-LIBS and SP-LIBS experiments. For a brass sample, significant increases in the spectral intensities of Cu and Zn lines were observed in DP-LIBS under Ar compared to DP-LIBS in air. It was also found that Cu and Zn lines acquired with SP-LIBS in Ar are nearly as intense as DP-LIBS in air. While collinear DP-LIBS is effective for increasing the sensitivity for some reduced atmospheres (i.e., Ar and air at 630 to 100 Torr and He at 300 Torr), the enhanced spectral intensity ultimately dropped off as the pressure was reduced below 10 Torr for all atmospheric compositions in the experimental arrangement used in this study. At all pressures of air and Ar, the plasma temperature remained rather constant with increased inter-pulse delays; however, the plasma temperature was more variable for different He gas pressures and inter-pulse delays.

6.
Sensors (Basel) ; 10(5): 4907-25, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22399914

RESUMO

Laser-induced breakdown spectroscopy (LIBS) is typically performed at ambient Earth atmospheric conditions. However, interest in LIBS in other atmospheric conditions has increased in recent years, especially for use in space exploration (e.g., Mars and Lunar) or to improve resolution for isotopic signatures. This review focuses on what has been reported about the performance of LIBS in reduced pressure environments as well as in various gases other than air.

7.
Astrobiology ; 8(2): 253-66, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18393691

RESUMO

The jarosite group minerals have received increasing attention since the discovery of jarosite on the martian surface by the Mars Exploration Rover Opportunity. Given that jarosite can incorporate foreign ions within its structure, we have investigated the use of jarosite as an indicator of aqueous and biological processes on Earth and Mars. The use of laser desorption Fourier transform mass spectrometry has revealed the presence of organic matter in several jarosite samples from various locations worldwide. One of the ions from the natural jarosites has been attributed to glycine because it was systematically observed in combinations of glycine with synthetic ammonium and potassium jarosites, Na(2)SO(4) and K(2)SO(4). The ability to observe these organic signatures in jarosite samples with an in situ instrumental technique, such as the one employed in this study, furthers the goals of planetary geologists to determine whether signs of life (e.g., the presence of biomolecules or biomolecule precursors) can be detected in the rock record of terrestrial and extraterrestrial samples.


Assuntos
Exobiologia , Meio Ambiente Extraterreno/química , Compostos Férricos/análise , Glicina/análise , Marte , Espectrometria de Massas , Sulfatos/análise , Análise de Fourier , Lasers , Origem da Vida
8.
Rev Sci Instrum ; 78(3): 035110, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17411220

RESUMO

The heart of an ion mobility spectrometer is the drift region where ion separation occurs. While the electrostatic potentials within a drift tube design can be modeled, no method for independently validating the electrostatic field has previously been reported. Two basic drift tube designs were modeled using SIMION 7.0 to reveal the expected electrostatic fields: (1) A traditional alternating set of electrodes and insulators and (2) a truly linear drift tube. One version of the alternating electrode/insulator drift tube and two versions of linear drift tubes were then fabricated. The stacked alternating electrodes/insulators were connected through a resistor network to generate the electrostatic gradient in the drift tube. The two linear drift tube designs consisted of two types of resistive drift tubes with one tube consisting of a resistive coating within an insulating tube and the other tube composed of resistive ferrites. The electrostatic fields within each type of drift tube were then evaluated by a noncontact method using a Kelvin-Zisman type electrostatic voltmeter and probe (results for alternative measurement methods provided in supplementary material). The experimental results were then compared with the electrostatic fields predicted by SIMION. Both the modeling and experimental measurements reveal that the electrostatic fields within a stacked ion mobility spectrometer drift tube are only pseudo-linear, while the electrostatic fields within a resistive drift tube approach perfect linearity.

9.
Talanta ; 72(2): 634-41, 2007 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-19071666

RESUMO

Polycyclic aromatic hydrocarbon (PAH) compounds and amino acids (AAs) are both ubiquitous throughout the universe and can be co-located in mineral matrices (e.g., meteorites); therefore, co-detection of PAHs and AAs associated with terrestrial and extra-terrestrial minerals is of interest. Nine PAH compounds representing four chemical classes of PAH (unsubstituted, acetyl-, amino-, and nitro-substituted) were applied onto the surface of quartz, plagioclase, olivine, and ilmenite mineral standards and analyzed using laser desorption/ionization Fourier transform mass spectrometry (LD-FTMS). Mass-to-charge peaks derived from PAH compounds were detected from the surfaces of all minerals evaluated. All PAH compounds were detected in the positive ion mode, whereas only nitro-substituted PAH compounds were detected in negative ion mode. In this and earlier studies, the ability to directly detect mineral-associated AAs by LD-FTMS was dependent on the mineral geomatrix. On iron-bearing minerals AAs appeared as highly fragmented ions in the spectra or were not detectable; however, the addition of the PAH chrysene enabled the ionization and detection of AAs threonine and histidine by LD-FTMS. Thus, for mineral systems such as meteorites, interstellar dust particles, soils, and sediments, the co-detection of AAs associated with PAHs by LD-FTMS is feasible.

10.
J Microbiol Methods ; 67(2): 381-4, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16815575

RESUMO

A new methodology for examining the interactions of microbes with heterogeneous minerals is presented. Imaging laser desorption Fourier transform mass spectrometry was used to examine the colonization patterns of Burkholderia vietnamiensis G4 (previously Burkholderia cepacia G4) on a heterogeneous basalt sample. Depth-profile imaging found that the bacterium preferentially colonized the plagioclase mineral phase within the basalt.


Assuntos
Burkholderia cepacia/química , Minerais/química , Silicatos/química , Análise de Fourier , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
11.
Inorg Chem ; 45(10): 3843-5, 2006 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-16676938

RESUMO

Microwave reaction of RuCl3 with 2,2'-bipyridinyl-4,4'-dicarboxylic acid diethyl ester (debpy) in ethylene glycol generated Ru(bpy)3(2+) instead of the expected Ru(debpy)3(2+). Gas chromatography-mass spectrometry analysis of the headspace revealed CO2, and Ru(bpy)3(2+) was recovered from the filtrate. Further experiments suggest that RuCl3 decarboxylates debpy during microwave synthesis.


Assuntos
Ésteres/química , Ésteres/efeitos da radiação , Micro-Ondas , Compostos Organometálicos/síntese química , Compostos Organometálicos/efeitos da radiação , Piridinas/química , Piridinas/efeitos da radiação , Rutênio/química , Rutênio/efeitos da radiação , Descarboxilação , Cromatografia Gasosa-Espectrometria de Massas , Espectroscopia de Ressonância Magnética/métodos , Compostos Organometálicos/química , Sensibilidade e Especificidade
12.
J Am Soc Mass Spectrom ; 14(4): 393-400, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12686486

RESUMO

Metal-bipyridine complexes are a vehicle for developing approaches for studying the fluorescence of gas-phase ions; however, conclusions regarding fluorescence behavior depend on explicitly identifying the ionic species in the gas phase. [Ru(bpy)(3)]X(2) and [Os(bpy(3))]X(2), (where bpy = 2,2'-bipyridine and X = Cl or PF(6)), were studied using direct laser desorption (LD) and matrix-assisted laser desorption/ionization (MALDI) using Fourier transform mass spectrometry (FTMS). LD spectra of the PF(6) salt of the Ru and Os complexes reveal counterion attachment, fluoride transfer, and significant losses of H for a number of peaks. LD of the chloride salt complexes produced loss of a single bpy ligand, chloride attachment, and losses of H. Spectra of [Ru(bpy(3)]X(2) where X = BF(4)(-), CF(3)SO(3)(-), and SCN(-) were also collected using LD and compared with the spectra for Cl(2) and PF(6) salts. Regardless of counterion, loss of H is observed in LD spectra. MALDI spectra of the trisbipyridyl complexes using 2,5-dihydroxybenzoic acid (DHB) and sinapinic acid (SA) as the matrix were also obtained. The spectra using SA as matrix show intact molecular ion peaks with very little fragmentation and no counterion attachment. Unlike SA, the spectra obtained using DHB look similar to LD spectra with significant losses of H. Our results are consistent with a reaction scheme for hydrogen loss from a carbon that also involves breaking of the metalz.sbnd;nitrogen bond, rotation of a pyridine ring, and re-formation of an ortho-metallated complex by a metalz.sbnd;C bond. These results demonstrate the importance of ion generation method and the utilization of FTMS for correct characterization of metal poly(pyridyl) complexes.