Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heart Rhythm O2 ; 4(3): 193-199, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36569386

RESUMO

Background: There are limited data on trends in nationwide cardiac electrophysiology (EP) procedures in the United States before and during the global COVID-19 pandemic. Objective: We aimed to understand contemporary EP procedural trends and how the COVID-19 pandemic impacted them. Methods: Trends were obtained from publicly reported Centers for Medicare and Medicaid Services data from 2013 to 2020 (latest available). Rates of catheter-based EP procedures (EP studies and ablations) and cardiac implantable electronic device (CIED) procedures were analyzed. All procedural rates were calculated per 100,000 Medicare beneficiaries (year specific). Procedure physician subspecialty was also reported. Results: From 2013 to 2019, annual rate of all cardiac EP procedures increased from 817.91 to 1089.68 per 100,000 beneficiaries. Catheter-based EP procedures increased from 323.73 to 675.01, while CIED rates decreased from 494.18 to 414.67. While all ablation procedures increased over time, relative proportion of ablation procedures being pulmonary vein isolation (PVI) increased (9.9% of ablations in 2013, to 18.2% in 2019). In 2020, rates of both catheter-based EP procedures and CIED procedures decreased; however, PVI share of ablation continued to increase in 2020 comprising 25.2% of ablation procedures. Conclusion: Rates of EP procedures have increased among Medicare beneficiaries, with catheter-based procedures now eclipsing CIEDs. Additionally, a greater proportion of catheter-based EP procedures are PVI, but they still represent a minority of all ablations. In 2020, rates of EP procedures were attenuated, yet the proportion of PVI ablations increased to over one-fourth of ablation procedures. These data have important implications for the EP workforce.

2.
Am Heart J Plus ; 22: 100211, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38558900

RESUMO

Objective: In chronic heart failure (HF) patients supported with continuous-flow left ventricular assist device (CF-LVAD), we aimed to assess the clinical association of pre-LVAD QRS duration (QRSd) with post-LVAD cardiac recovery, and its correlation with pre- to post-LVAD change in left ventricular ejection fraction (LVEF) and left ventricular end-diastolic diameter (LVEDD). Methods: Chronic HF patients (n = 402) undergoing CF-LVAD implantation were prospectively enrolled, at one of the centers comprising the U.T.A.H. (Utah Transplant Affiliated Hospitals) consortium. After excluding patients with acute HF etiologies, hypertrophic or infiltrative cardiomyopathy, and/or inadequate post-LVAD follow up (<3 months), 315 patients were included in the study. Cardiac recovery was defined as LVEF ≥ 40 % and LVEDD < 6 cm within 12 months post-LVAD implantation. Patients fulfilling this condition were termed as responders (R) and results were compared with non-responders (NR). Results: Thirty-five patients (11 %) achieved 'R' criteria, and exhibited a 15 % shorter QRSd compared to 'NR' (123 ± 37 ms vs 145 ± 36 ms; p < 0.001). A univariate analysis identified association of baseline QRSd with post-LVAD cardiac recovery (OR: 0.986, 95 % CI: 0.976-0.996, p < 0.001). In a multivariate logistic regression model, after adjusting for duration of HF (OR: 0.990, 95 % CI: 0.983-0.997, p = 0.006) and gender (OR: 0.388, 95 % CI: 0.160-0.943, p = 0.037), pre-LVAD QRSd exhibited a significant association with post-LVAD cardiac structural and functional improvement (OR: 0.987, 95 % CI: 0.977-0.998, p = 0.027) and the predictive model showed a c-statistic of 0.73 with p < 0.001. The correlations for baseline QRSd with pre- to post-LVAD change in LVEF and LVEDD were also investigated in 'R' and 'NR' groups. Conclusion: Chronic advanced HF patients with a shorter baseline QRSd exhibit an increased potential for cardiac recovery after LVAD support.

3.
Arrhythm Electrophysiol Rev ; 10(3): 205-210, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34777826

RESUMO

AF has been consistently associated with multiple forms of dementia, including idiopathic dementia. Outcomes after catheter ablation for AF are favourable and patients experience a better quality of life, arrhythmia-free survival, and lower rates of hospitalisation compared to patients treated with antiarrhythmic drugs. Catheter ablation is consistently associated with lower rates of stroke compared to AF management without ablation in large national and healthcare system databases. Multiple observational trials have shown that catheter ablation is also associated with a lower risk of cognitive decline, dementia and improved cognitive testing that can be explained through a variety of pathways. Long-term, adequately powered, randomised trials are required to define the role of catheter ablation in the management of AF as a means to lower the risk of cognitive decline, stroke and dementia.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...