2.
Pediatr Cardiol ; 35(7): 1124-31, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24723210

RESUMO

This study aimed to assess the technical aspects of atrial septal defect (ASD) closure using the Amplatzer septal occluder (ASO) and the Gore Helex septal occluder (GHSO) for infants weighing less than 8 kg and to determine the safety, effectiveness, and near-to-intermediate-term outcome of the closure. The Mid-Atlantic Group of Interventional Cardiology Registry of percutaneous, transcatheter ASD closure procedures was reviewed for this analysis. Patients from 10 hospitals in the United States were included. The cohort for this report consisted of 68 patients weighing less than 8 kg (range, 2.3-7.8 kg; mean, 5.5 ± 1.6 kg) and ranging in age from 1 to 24 months (mean, 8.6 ± 4.7 months). The indications for ASD closure were failure to thrive, significant right heart enlargement, shunts otherwise thought to be hemodynamically significant, and poor overall clinical status. Devices were successfully implanted in 66 of the 68 infants (97.1 % procedural success rate). Five minor procedure-related complications occurred. At follow-up assessment, clinical status had improved significantly as measured by improved weight gain and decreased ventilator or oxygen dependence. All residual shunts spontaneously closed during the follow-up period. Six late deaths occurred, none of which were clearly device related. The ASO and GHSO can be safely and effectively implanted for ASD closure in infants weighing less than 8 kg. These procedures usually are successful and seldom complicated, resulting in significant clinical improvement.


Assuntos
Peso Corporal , Cateterismo Cardíaco/métodos , Comunicação Interatrial/cirurgia , Dispositivo para Oclusão Septal , Pré-Escolar , Ecocardiografia , Feminino , Fluoroscopia , Seguimentos , Comunicação Interatrial/diagnóstico , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
3.
J Card Surg ; 28(4): 391-3, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23772880

RESUMO

We present the technique of transcatheter balloon expandable (MELODY®) valve-in-valve deployment in a frail octogenarian with a failed previous tricuspid bioprosthesis. In patients who are not candidates for conventional surgery, transcatheter approach provides an alternative that warrants careful consideration.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Desenho de Prótese , Falha de Prótese , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso de 80 Anos ou mais , Animais , Cateterismo Cardíaco/métodos , Bovinos , Feminino , Humanos , Veias Jugulares , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Cirurgia Assistida por Computador/métodos