Artigo em Inglês | MEDLINE | ID: mdl-24697972

RESUMO

OBJECTIVE: To determine if blood pressure measured with an ultrasonic Doppler flow detector (Doppler) is in good agreement with directly measured blood pressures in anesthetized cats. DESIGN: Prospective observational study. SETTING: University veterinary teaching hospital. ANIMALS: Thirty-nine cats undergoing routine neutering. INTERVENTIONS: Cats were divided into 2 groups; 19 cats enrolled in Group A had a 24-Ga catheter inserted into a dorsal pedal artery; 20 cats in Group B had a 20-Ga catheter placed in a femoral artery. In both groups, systolic, diastolic, and mean arterial pressures were directly measured using a validated pressure measurement system. Indirect values were compared against direct blood pressure measurements. RESULTS: There was no difference between groups. Overall, there was poor agreement with a significant bias observed between Doppler and directly measured blood pressures. For the systolic arterial pressure the bias was -8.8 with limits of agreements (LOA) of -39.3 and 21.7. For the mean arterial pressure, the bias was 14.0 with LOA of -13.9 and 41.9. For the diastolic arterial pressure, the bias was 27.9 with LOA of -4.4 and 60.2. Methodology, weight, sex, and replicates did not have a significant effect on the difference between indirect and direct measurements in any model. CONCLUSIONS: Results suggest poor agreement between Doppler values and directly measured blood pressures in anesthetized cats. Use of Doppler in cats could be misleading and readings should be interpreted with caution in a clinical context.


Assuntos
Anestesia/veterinária , Monitores de Pressão Arterial/veterinária , Pressão Sanguínea/fisiologia , Gatos/fisiologia , Animais , Determinação da Pressão Arterial/instrumentação , Determinação da Pressão Arterial/veterinária , Feminino , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia Doppler/veterinária
2.
J Am Vet Med Assoc ; 237(4): 402-6, 2010 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-20707750

RESUMO

OBJECTIVE: To determine whether veterinary-specific oscillometric blood pressure units yield measurements that are in good agreement with directly measured blood pressures in cats. DESIGN: Evaluation study. ANIMALS: 21 cats undergoing routine spaying or neutering. PROCEDURES: A 24-gauge catheter was inserted in a dorsal pedal artery, and systolic, diastolic, and mean arterial pressures were directly measured with a validated pressure measurement system. Values were compared with indirect blood pressure measurements obtained with 3 veterinary-specific oscillometric blood pressure units. RESULTS: There was poor agreement between indirectly and directly measured blood pressures. For unit 1, bias between indirectly and directly measured values was -14.9 mm Hg (95% limits of agreement [LOA], -52.2 to 22.4 mm Hg), 4.4 mm Hg (95% LOA, -26.0 to 34.8 mm Hg), and -1.3 mm Hg (95% LOA, -26.7 to 24.1 mm Hg) for systolic, diastolic, and mean arterial pressures, respectively. For unit 2, bias was -10.3 mm Hg (95% LOA, -52.9 to 32.2 mm Hg), 13.0 mm Hg (95% LOA, -32.1 to 58.0 mm Hg), and 9.1 mm Hg (95% LOA, -32.9 to 51.2 mm Hg) for systolic, diastolic, and mean arterial pressures, respectively. For unit 3, bias was -13.4 mm Hg (95% LOA, -51.8 to 25.1 mm Hg), 8.0 mm Hg (95% LOA, -25.5 to 41.6 mm Hg), and -3.6 mm Hg (95% LOA, -31.6 to 24.5 mm Hg) for systolic, diastolic, and mean arterial pressures, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that none of the 3 veterinary-specific oscillometric blood pressure units could be recommended for indirect measurement of blood pressure in cats.


Assuntos
Monitores de Pressão Arterial/veterinária , Pressão Sanguínea/fisiologia , Gatos/fisiologia , Oscilometria/veterinária , Animais , Oscilometria/instrumentação