Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Intensive Care Soc ; 21(2): 105-110, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32489405

RESUMO

INTRODUCTION: Extracorporeal cardiopulmonary resuscitation (ECPR) is an internationally recognised treatment for refractory cardiac arrest, with evidence of improved outcomes in selected patient groups from cohort studies and case series. In order to establish the clinical need for an in-hospital extracorporeal cardiopulmonary resuscitation service at a tertiary cardiac centre, we analysed the inpatient cardiac arrest database for the previous 12 months. METHODS: Evidence-based inclusion criteria were used to retrospectively identify the number of patients potentially eligible for extracorporeal cardiopulmonary resuscitation over a 12-month period. RESULTS: A total of 261 inpatient cardiac arrests were analysed with 21 potential extracorporeal cardiopulmonary resuscitation candidates meeting the inclusion criteria (1.75 patients per month, or 8% of inpatient cardiac arrests (21/261)). The majority (71%) of these cardiac arrests occurred outside of normal working hours. Survival-to-discharge within this sub-group with conventional cardiopulmonary resuscitation was 19% (4/21). CONCLUSION: Sufficient numbers of refractory inpatient cardiac arrests occur to justify an extracorporeal cardiopulmonary resuscitation service, but a 24-h on-site extracorporeal membrane oxygenation team presents a significant financial and logistical challenge.

2.
BMJ Open Qual ; 8(2): e000378, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31259274

RESUMO

The use of a marker ball in digital templating for hip arthroplasty is a well-established method of preoperative planning and is used to overcome the inherent magnification in plain film radiographs. Our hospital policy is to place a marker ball in all anteroposterior pelvic films taken in the emergency department (ED) which have been requested for suspected neck of femur fractures. We carried out a baseline measurement followed by three Plan-Do-Study-Act cycles for all pelvic films taken in ED during July 2016, November 2016, February 2017 and November 2017. Interventions between the baseline measurement and cycle 1 were to educate the lead radiographer and publish the results in the radiology newsletter, and between cycles 1 and 2 was to run a teaching session for radiographers, display posters in the X-ray department and place an electronic prompt on the X-ray machine to alert them of the need to place a marker ball in the X-ray field. Cycle 3 looked to see if improvements were sustained. 16/81 (20%) radiographs complied with the policy in our baseline measurement; 25/51 (46%, p=0.002) in cycle 1; 40/54 (74%, p=0.0056) in cycle 2; and 48/63 (76%) in cycle 3. Our quality improvement project led to large improvements in clinical practice through straightforward, small, but appropriately targeted interventions. Stakeholder management is key to successfully implementing change. The next step is to switch from the VoyantMark to the KingMark marker ball, as it has greater accuracy of templating and is also easier to place within the field of an X-ray.


Assuntos
Ampliação Radiográfica/efeitos adversos , Radiografia/métodos , Radiografia/normas , Fraturas do Colo Femoral/diagnóstico por imagem , Humanos , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/normas , Cuidados Pré-Operatórios/estatística & dados numéricos , Ampliação Radiográfica/métodos , Radiografia/estatística & dados numéricos , Participação dos Interessados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...