Rev Sci Instrum ; 94(1): 013101, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725595

RESUMO

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX's) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3-11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 µm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics' OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

2.
Artigo em Inglês | MEDLINE | ID: mdl-31093030

RESUMO

The properties of hot, dense plasmas generated by the irradiation of GaAs targets by the Titan laser at Lawrence Livermore National Laboratory were determined by the analysis of high resolution K shell spectra in the 9 keV to 11 keV range. The laser parameters, such as relatively long pulse duration and large focal spot, were chosen to produce a steady-state plasma with minimal edge gradients, and the time-integrated spectra were compared to non-LTE steady state spectrum simulations using the FLYCHK and NOMAD codes. The bulk plasma streaming velocity was measured from the energy shifts of the Ga He-like transitions and Li-like dielectronic satellites. The electron density and the electron energy distribution, both the thermal and the hot non-thermal components, were determined from the spectral line ratios. After accounting for the spectral line broadening contributions, the plasma turbulent motion was measured from the residual line widths. The ionization balance was determined from the ratios of the He-like through F-like spectral features. The detailed comparison of the experimental Ga spectrum and the spectrum simulated by the FLYCHK code indicates two significant discrepancies, the transition energy of a Li-like dielectronic satellite (designated t) and the calculated intensity of a He-like line (x), that should lead to improvements in the kinetics codes used to simulate the X-ray spectra from highly-charged ions.

3.
Rev Sci Instrum ; 87(11): 11E305, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910617

RESUMO

A Cauchois transmission-crystal spectrometer has been developed with high crystal resolving power in the 6 keV-15 keV energy range and sufficient sensitivity to record single-shot spectra from the Lawrence Livermore National Laboratory (LLNL) Titan laser and other comparable or more energetic lasers. The spectrometer capabilities were tested by recording the W L transitions from a laboratory source and the extended x-ray absorption fine structure (EXAFS) spectrum through a Cu foil.

4.
Artigo em Inglês | MEDLINE | ID: mdl-31093029

RESUMO

Experiments were performed at the LLNL Titan laser to measure the propagation direction of the energetic electrons that were generated during the interaction of the polarized laser beam with solid targets in the case of normal incidence. The energetic electrons propagated through vacuum to spectator metal wires in the polarization direction and in the perpendicular direction, and the K shell spectra from the different wire materials were recorded as functions of the distance from the laser focal spot. It was found that the fluence of the energetic electrons driven into the spectator wires in the polarization direction compared to the perpendicular direction was larger and increased with the distance from the focal spot. This indicates that energetic electrons are preferentially driven in the direction of the intense oscillating electric field of the incident laser beam in agreement with the multiphoton inverse Bremsstrahlung absorption process.

5.
Rev Sci Instrum ; 85(11): 11D618, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430194

RESUMO

A high resolution crystal spectrometer utilizing a crystal in transmission geometry has been developed and experimentally optimized to measure the widths of emission lines in the 10-60 keV energy range with eV accuracy. The spectrometer achieves high spectral resolution by utilizing crystal planes with small lattice spacings (down to 2d = 0.099 nm), a large crystal bending radius and Rowland circle diameter (965 mm), and an image plate detector with high spatial resolution (60 µm in the case of the Fuji TR image plate). High resolution W L-shell and K-shell laboratory test spectra in the 10-60 keV range and Ho K-shell spectra near 47 keV recorded at the LLNL Titan laser facility are presented. The Ho K-shell spectra are the highest resolution hard x-ray spectra recorded from a solid target irradiated by a high-intensity laser.

6.
Rev Sci Instrum ; 83(10): 10E110, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126932

RESUMO

Close to an x-ray filter's K-edge the transmission depends strongly on the photon energy. For a few atom pairs, the K-edge of one is only a few tens of eV higher than a K-line energy of another, so that a small change in the line's energy becomes a measurable change in intensity behind such a matching filter. Lutetium's K-edge is ≃27 eV above iridium's Kα(2) line, ≃63.287 keV for cold Ir. A Lu filter reduces this line's intensity by ≃10 % when it is emitted by a plasma, indicating an ionization shift Δε≃10±1 eV.

7.
Rev Sci Instrum ; 83(4): 043104, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22559512

RESUMO

In the pursuit of novel, laser-produced x-ray sources for medical imaging applications, appropriate instrumental diagnostics need to be developed concurrently. A type of transmission crystal spectroscopy has previously been demonstrated as a survey tool for sources produced by high-power and high-energy lasers. The present work demonstrates the extension of this method into the study of medium-intensity laser driven hard x-ray sources with a design that preserves resolving power while maintaining high sensitivity. Specifically, spectroscopic measurements of characteristic Kα and Kß emissions were studied from Mo targets irradiated by a 100 fs, 200 mJ, Ti: sapphire laser with intensity of 10(17) W/cm(2) to 10(18) W∕cm(2) per shot. Using a transmission curved crystal spectrometer and off-Rowland circle imaging, resolving powers (E/ΔE) of around 300 for Mo Kα(2) at 17.37 keV were obtained with an end-to-end spectrometer efficiency of (1.13 ± 0.10) × 10(-5). This sensitivity is sufficient for registering x-ray lines with high signal to background from targets following irradiation by a single laser pulse, demonstrating the utility of this method in the study of the development of medium-intensity laser driven x-ray sources.

8.
Rev Sci Instrum ; 81(10): 10E302, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034001

RESUMO

The plasma-filled rod-pinch diode (PFRP) is an intense source of x-rays ideal for radiography of dense objects. In the PRFP megavoltage electrons from a pulsed discharge concentrate at the pointed end of a 1 mm diameter tapered tungsten rod. Ionization of this plasma might increase the energy of tungsten's Kα(1) fluorescence line, at 59.3182 keV, enough for the difference to be observed by a high-resolution Cauchois transmission crystal spectrograph. When the PFRP's intense hard bremsstrahlung is suppressed by the proper shielding, such an instrument gives excellent fluorescence spectra, albeit with as yet insufficient resolution to see any effect of tungsten's ionization. Higher resolution is possible with various straightforward upgrades that are feasible thanks to the radiation's high intensity.

9.
Rev Sci Instrum ; 81(10): 10E301, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034000

RESUMO

The transmission crystal spectrometer (TCS) is approved for taking data at the OMEGA-EP laser facility since 2009 and will be available for the OMEGA target chamber in 2010. TCS utilizes a Cauchois type cylindrically bent transmission crystal geometry with a source to crystal distance of 600 mm. Spectral images are recorded by image plates in four positions, one IP on the Rowland circle and three others at 200, 400, and 600 mm beyond the Rowland circle. An earlier version of TCS was used at LULI on experiments that determined the x-ray source size from spectral line broadening on one IP positioned behind the Rowland circle. TCS has recorded numerous backlighter spectra at EP for point projection radiography and for source size measurements. Hard x-ray source size can be determined from the source broadening of both K shell emission lines and from K absorption edges in the bremsstrahlung continuum, the latter being a new way to measure the spatial extent of the hard x-ray bremsstrahlung continuum.

10.
Rev Sci Instrum ; 81(10): 10E311, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034010

RESUMO

The potential of an x-ray magnifier prepared from a pair of asymmetrically cut crystals is studied to explore high energy x-ray imaging capabilities at high intensity laser facilities. OMEGA-EP and NIF when irradiating mid and high Z targets can be a source of high-energy x-rays whose production mechanisms and use as backlighters are a subject of active research. This paper studies the properties and potential of existing asymmetric cut crystal pairs from the National Institute of Standards and Technology (NIST) built in a new enclosure for imaging x-ray sources. The technique of the x-ray magnifier has been described previously. This new approach is aimed to find a design that could be used at laser facilities by magnifying the x-ray source into a screen far away from the target chamber center, with fixed magnification defined by the crystals' lattice spacing and the asymmetry angles. The magnified image is monochromatic and the imaging wavelength is set by crystal asymmetry and incidence angles. First laboratory results are presented and discussed.

11.
Rev Sci Instrum ; 81(10): 10E320, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034018

RESUMO

The dual crystal spectrometer (DCS) is an approved diagnostic at the OMEGA and the OMEGA-EP laser facilities for the measurement of high energy x-rays in the 11-90 keV energy range, e.g., for verification of the x-ray spectrum of backlighter targets of point projection radiography experiments. DCS has two cylindrically bent transmission crystal channels with image plate detectors at distances behind the crystals close to the size of the respective Rowland circle diameters taking advantage of the focusing effect of the cylindrically bent geometry. DCS, with a source to crystal distance of 1.2 m, provides the required energy dispersion for simultaneous detection of x-rays in a low energy channel (11-45 keV) and a high-energy channel (19-90 keV). A scaling study is described for varied pulse length with unchanged laser conditions (energy, focusing). The study shows that the Kα line intensity is not strongly dependent on the length of the laser pulse.

12.
Appl Opt ; 45(8): 1680-7, 2006 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-16572682

RESUMO

Efficiency measurements of a grazing-incidence diffraction grating in the off-plane mount were performed using polarized synchrotron radiation. The grating had 5000 grooves/mm, an effective blaze angle of 14 degrees, and was gold coated. The efficiencies in the two polarization orientations (TM and TE) were measured in the 1.5-5.0 nm wavelength range and were compared with the efficiencies calculated using the PCGrate-SX code. The TM and TE efficiencies differ, offering the possibility of performing unique science studies of astrophysical, solar, and laboratory sources by exploiting the polarization sensitivity of the off-plane grating.

13.
Phys Rev Lett ; 94(4): 045002, 2005 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-15783564

RESUMO

Absolutely calibrated, time-resolved spectral intensity measurements of soft-x-ray emission (hnu approximately 0.1-1.0 keV) from laser-irradiated polystyrene targets are compared to radiation-hydrodynamic simulations that include our new postprocessor, Virtual Spectro. This new capability allows a unified, detailed treatment of atomic physics and radiative transfer in nonlocal thermodynamic equilibrium conditions for simple spectra from low-Z materials as well as complex spectra from high-Z materials. The excellent agreement (within a factor of approximately 1.5) demonstrates the powerful predictive capability of the codes for the complex conditions in the ablating plasma. A comparison to data with high spectral resolution (E/deltaE approximately 1000) emphasizes the importance of including radiation coupling in the quantitative simulation of emission spectra.

14.
J Trauma ; 59(6): 1463-8, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16394923

RESUMO

BACKGROUND: The purpose of this study was to record flash x-ray images of cavitation in human cadaver thighs caused by the passage of high-velocity bullets. The images are an initial step for understanding the cavitation process in human tissue and for implementing a better definition of extensive tissue injury. METHODS: Bullets were fired through the mid-thighs of 13 cadaver legs. The bullets were of two calibers, 7.62-mm full metal jacket boat tail with strike velocities in the range of 794 m/s to 880 m/s (10 thighs) and 5.70 mm full metal jacket with velocities in the range of 973 m/s to 992 m/s (3 thighs). Short duration (35 ns) x-ray images were recorded at various selected times after the bullets passed near the femurs. This study was carried out at the Armed Forces Institute of Pathology under approved human subject protocols. RESULTS: The cavity sizes and shapes were observed for the two types of bullets and at a number of times during the expansion and collapse of the cavities. As the bullets passed through the thighs, narrow cavities behind the bullets were observed. At later times, large expanded cavities were observed that encompassed the entire mid-thigh region. The observed cavities are at variance with those which were reported previously in gelatin tissue simulants. CONCLUSION: Flash x-ray radiography is an effective technique for the observation of internal cavitation in cadaver thighs caused by high-velocity bullets. These observations suggest that gelatin is not a proven simulant for human cadaver tissue in the study of cavitation subsequent to high-velocity missile impact.


Assuntos
Coxa da Perna/diagnóstico por imagem , Coxa da Perna/lesões , Ferimentos por Arma de Fogo/diagnóstico por imagem , Cadáver , Fêmur/diagnóstico por imagem , Fêmur/lesões , Fêmur/patologia , Humanos , Intensificação de Imagem Radiográfica , Lesões dos Tecidos Moles/diagnóstico por imagem , Lesões dos Tecidos Moles/patologia , Coxa da Perna/patologia , Ferimentos por Arma de Fogo/patologia
15.
Appl Opt ; 40(10): 1623-30, 2001 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18357156

RESUMO

The responsivity of an extreme-ultraviolet transmission grating spectrometer with silicon photodiode detectors was measured with synchrotron radiation. The spectrometer was designed to record the absolute radiation flux in a wavelength bandpass centered at 30 nm. The transmission grating had a period of 200 nm and relatively high efficiencies in the +1 and the -1 diffraction orders that were dispersed on either side of the zero-order beam. Three photodiodes were positioned to measure the signals in the zero order and in the +1 and -1 orders. The photodiodes had aluminum overcoatings that passed the desired wavelength bandpass centered at 30 nm and attenuated higher-order radiation and wavelengths longer than approximately 80 nm. The spectrometer's responsivity, the ratio of the photodiode current to the incident radiation power, was determined as a function of the incident wavelength and the angle of the spectrometer with respect to the incident radiation beam. The spectrometer's responsivity was consistent with the product of the photodiode responsivity and the grating efficiency, both of which were separately measured while removed from the spectrometer.

16.
Appl Opt ; 40(31): 5565-74, 2001 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-18364842

RESUMO

MoRu-Be multilayer coatings were applied to two diffraction gratings for the purpose of enhancing their normal-incidence efficiency in the 11.1-12.0-nm wavelength range. The grating substrates were replicas of a holographic master grating that had a blazed groove profile with 2400 grooves/mm and a 2-m radius of curvature. The relatively low average microroughness (0.8 nm) of the grating surfaces contributed to the relatively high groove efficiency of the grating substrates and the reflectance of the MoRu-Be multilayer coatings. The peak efficiency, measured with synchrotron radiation, was 10.4% in the second diffraction order at a wavelength of 11.37 nm.

17.
Opt Lett ; 26(3): 125-7, 2001 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18033524

RESUMO

A MoRu-Be multilayer coating was applied to a diffraction grating to enhance the grating's normal-incidence efficiency near 11.4 nm wavelength. The holographic grating substrate had a blazed groove profile with 2400 grooves/mm and a microroughness of 0.8 nm. The efficiency in the second diffraction order, measured with synchrotron radiation, was 10.4% at a wavelength of 11.37 nm.

18.
20.
Appl Opt ; 38(7): 1251-8, 1999 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-18305740

RESUMO

Thin-film interference effects were observed in the normal-incidence efficiency of a 2400-groove/mm replica grating. The efficiency was measured in the 100-350-A wavelength range and had an oscillatory behavior that resulted from the presence of a thin SiO(2) coating. The thicknesses of the SiO(2) and the underlying oxidized aluminum layers were inferred from computer modeling of the zero-order efficiency. The efficiencies in the diffracted orders were calculated with the modified integral approach and accounting for the multilayer coating and the groove profile derived from atomic force microscopy. The calculated and measured efficiencies were in good agreement.