2.
Mov Disord ; 39(5): 788-797, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38419144

RESUMO

BACKGROUND: With disease-modifying drugs in reach for cerebellar ataxias, fine-grained digital health measures are highly warranted to complement clinical and patient-reported outcome measures in upcoming treatment trials and treatment monitoring. These measures need to demonstrate sensitivity to capture change, in particular in the early stages of the disease. OBJECTIVE: Our aim is to unravel gait measures sensitive to longitudinal change in the-particularly trial-relevant-early stage of spinocerebellar ataxia type 2 (SCA2). METHODS: We performed a multicenter longitudinal study with combined cross-sectional and 1-year interval longitudinal analysis in early-stage SCA2 participants (n = 23, including nine pre-ataxic expansion carriers; median, ATXN2 CAG repeat expansion 38 ± 2; median, Scale for the Assessment and Rating of Ataxia [SARA] score 4.8 ± 4.3). Gait was assessed using three wearable motion sensors during a 2-minute walk, with analyses focused on gait measures of spatio-temporal variability that have shown sensitivity to ataxia severity (eg, lateral step deviation). RESULTS: We found significant changes for gait measures between baseline and 1-year follow-up with large effect sizes (lateral step deviation P = 0.0001, effect size rprb = 0.78), whereas the SARA score showed no change (P = 0.67). Sample size estimation indicates a required cohort size of n = 43 to detect a 50% reduction in natural progression. Test-retest reliability and minimal detectable change analysis confirm the accuracy of detecting 50% of the identified 1-year change. CONCLUSIONS: Gait measures assessed by wearable sensors can capture natural progression in early-stage SCA2 within just 1 year-in contrast to a clinical ataxia outcome. Lateral step deviation represents a promising outcome measure for upcoming multicenter interventional trials, particularly in the early stages of cerebellar ataxia. © 2024 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Assuntos
Progressão da Doença , Ataxias Espinocerebelares , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Ataxias Espinocerebelares/fisiopatologia , Ataxias Espinocerebelares/genética , Estudos Longitudinais , Estudos Transversais , Marcha/fisiologia , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Transtornos Neurológicos da Marcha/diagnóstico , Ataxina-2/genética
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2976-2982, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085677

RESUMO

In modern psychotherapy, digital health technology offers advanced and personalized therapy options, increasing availability as well as ecological validity. These aspects have proven to be highly relevant for children and adolescents with obsessive-compulsive disorder (OCD). Exposure and Response Prevention therapy, which is the state-of-the-art treatment for OCD, builds on the reconstruction of everyday life exposure to anxious situations. However, while compulsive behavior pre-dominantly occurs in home environments, exposure situations during therapy are limited to clinical settings. Telemedical treatment allows to shift from this limited exposure reconstruction to exposure situations in real life. In the SSTeP KiZ study (smart sensor technology in telepsychotherapy for children and adolescents with OCD), we combine video therapy with wearable sensors delivering physiological and behavioral measures to objectively determine the stress level of patients. The setup allows to gain information from exposure to stress in a realistic environment both during and outside of therapy sessions. In a first pilot study, we explored the sensitivity of individual sensor modalities to different levels of stress and anxiety. For this, we captured the obsessive-compulsive behavior of five adolescents with an ECG chest belt, inertial sensors capturing hand movements, and an eye tracker. Despite their prototypical nature, our results deliver strong evidence that the examined sensor modalities yield biomarkers allowing for personalized detection and quantification of stress and anxiety. This opens up future possibilities to evaluate the severity of individual compulsive behavior based on multi-variate state classification in real-life situations. Clinical Relevance- Our results demonstrate the potential for efficient personalized psychotherapy by monitoring physiological and behavioral changes with multiple sensor modalities in ecologically valid real-life scenarios.


Assuntos
Transtorno Obsessivo-Compulsivo , Telemedicina , Adolescente , Transtornos de Ansiedade , Proteínas de Ciclo Celular , Criança , Humanos , Transtorno Obsessivo-Compulsivo/diagnóstico , Transtorno Obsessivo-Compulsivo/terapia , Projetos Piloto , Psicoterapia
5.
Mov Disord ; 37(5): 1047-1058, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35067979

RESUMO

BACKGROUND: Clinical and regulatory acceptance of upcoming molecular treatments in degenerative ataxias might greatly benefit from ecologically valid endpoints that capture change in ataxia severity in patients' real life. OBJECTIVES: This longitudinal study aimed to unravel quantitative motor biomarkers in degenerative ataxias in real-life turning movements that are sensitive for changes both longitudinally and at the preataxic stage. METHODS: Combined cross-sectional (n = 30) and longitudinal (n = 14, 1-year interval) observational study in degenerative cerebellar disease (including eight preataxic mutation carriers) compared to 23 healthy controls. Turning movements were assessed by three body-worn inertial sensors in three conditions: (1) instructed laboratory assessment, (2) supervised free walking, and (3) unsupervised real-life movements. RESULTS: Measures that quantified dynamic balance during turning-lateral velocity change (LVC) and outward acceleration-but not general turning measures such as speed, allowed differentiating ataxic against healthy subjects in real life (effect size δ = 0.68), with LVC also differentiating preataxic against healthy subjects (δ = 0.53). LVC was highly correlated with clinical ataxia severity (scale for the assessment and rating of ataxia [SARA] score, effect size ρ = 0.79) and patient reported balance confidence (activity-specific balance confidence scale [ABC] score, ρ = 0.66). Moreover, LVC in real life-but not general turning measures or the SARA score-allowed detecting significant longitudinal change in 1-year follow-up with high effect size (rprb  = 0.66). CONCLUSIONS: Measures of turning allow capturing specific changes of dynamic balance in degenerative ataxia in real life, with high sensitivity to longitudinal differences in ataxia severity and to the preataxic stage. They thus present promising ecologically valid motor biomarkers, even in the highly treatment-relevant early stages of degenerative cerebellar disease. © 2022 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Assuntos
Ataxia Cerebelar , Ataxias Espinocerebelares , Ataxia , Biomarcadores , Estudos Transversais , Humanos , Estudos Longitudinais , Ataxias Espinocerebelares/genética
6.
Neurology ; 95(9): e1199-e1210, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32611635

RESUMO

OBJECTIVES: With disease-modifying drugs on the horizon for degenerative ataxias, ecologically valid motor biomarkers are highly warranted. In this observational study, we aimed to unravel and validate markers of ataxic gait in real life by using wearable sensors. METHODS: We assessed gait characteristics of 43 patients with degenerative cerebellar disease (Scale for the Assessment and Rating of Ataxia [SARA] 9.4 ± 3.9) compared with 35 controls by 3 body-worn inertial sensors in 3 conditions: (1) laboratory-based walking; (2) supervised free walking; (3) real-life walking during everyday living (subgroup n = 21). Movement analysis focused on measures of spatiotemporal step variability and movement smoothness. RESULTS: A set of gait variability measures was identified that allowed us to consistently identify ataxic gait changes in all 3 conditions. Lateral step deviation and a compound measure of spatial step variability categorized patients vs controls with a discrimination accuracy of 0.86 in real life. Both were highly correlated with clinical ataxia severity (effect size ρ = 0.76). These measures allowed detecting group differences even for patients who differed only 1 point in the clinical SARAposture&gait subscore, with highest effect sizes for real-life walking (d = 0.67). CONCLUSIONS: We identified measures of ataxic gait that allowed us not only to capture the gait variability inherent in ataxic gait in real life, but also to demonstrate high sensitivity to small differences in disease severity, with the highest effect sizes in real-life walking. They thus represent promising candidates for motor markers for natural history and treatment trials in ecologically valid contexts. CLASSIFICATION OF EVIDENCE: This study provides Class I evidence that a set of gait variability measures, even if accessed in real life, correlated with the clinical severity of ataxia in patients with degenerative cerebellar disease.


Assuntos
Análise da Marcha/métodos , Ataxias Espinocerebelares/fisiopatologia , Dispositivos Eletrônicos Vestíveis , Adulto , Idoso , Ataxia Telangiectasia/fisiopatologia , Feminino , Análise da Marcha/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Equilíbrio Postural , Índice de Gravidade de Doença , Caminhada , Adulto Jovem