OBJECTIVE: The power balance of multichannel transmit coils is a central consideration in assessing performance and safety issues. At ultrahigh fields, in addition to absorption and reflection, radiofrequency (RF) radiation into the far field becomes a concern. MATERIALS AND METHODS: We engineered a system for in situ measurement of complex-valued scattering parameter (S-parameter) matrices of multichannel transmit coils that allows for the calculation of the reflected and accepted power for arbitrary steering conditions. The radiated power from an RF coil inside a large single-mode waveguide couples to that mode. Finite-difference time-domain simulations were used for the calculations, and E-field probes were used to measure the electric field distribution, and hence the radiated power, in the waveguide. To test this concept, an eight-channel shielded-loop array for 7T imaging was studied inside a 280-cm-long cylindrical waveguide with a 60-cm diameter. RESULTS: For a 7T parallel-transmit coil, the S-parameters were measured and the reflected power calculated as a function of steering conditions. Maximum radiated power was observed for the circularly polarized mode. CONCLUSION: A system was developed for in situ S-parameter measurements combined with a method for determining radiated power, allowing a complete assessment of the power balance of multichannel transmit coils at 7T.


Assuntos
Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Ondas de Rádio , Algoritmos , Radiação Eletromagnética , Desenho de Equipamento , Equipamentos e Provisões , Segurança do Paciente , Imagens de Fantasmas , Polietileno/química , Espalhamento de Radiação
2.
PLoS One ; 8(4): e61661, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23613896

RESUMO

This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B0 = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B0 which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (ΔT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19×23×32)mm(3) iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device.


Assuntos
Campos Eletromagnéticos , Hipertermia Induzida/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Ondas de Rádio , Desenho de Equipamento , Estudos de Viabilidade , Humanos