Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Crohns Colitis ; 13(9): 1111-1120, 2019 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-30768123

RESUMO

BACKGROUND & AIMS: Vedolizumab is an anti-a4b7 monoclonal antibody that is licensed for the treatment of moderate to severe Crohn's disease and ulcerative colitis. The aims of this study were to establish the real-world effectiveness and safety of vedolizumab for the treatment of inflammatory bowel disease. METHODS: This was a retrospective study involving seven NHS health boards in Scotland between June 2015 and November 2017. Inclusion criteria included: a diagnosis of ulcerative colitis or Crohn's disease with objective evidence of active inflammation at baseline (Harvey-Bradshaw Index[HBI] ≥5/Partial Mayo ≥2 plus C-reactive protein [CRP] >5 mg/L or faecal calprotectin ≥250 µg/g or inflammation on endoscopy/magnetic resonance imaging [MRI]); completion of induction; and at least one clinical follow-up by 12 months. Kaplan-Meier survival analysis was used to establish 12-month cumulative rates of clinical remission, mucosal healing, and deep remission [clinical remission plus mucosal healing]. Rates of serious adverse events were described quantitatively. RESULTS: Our cohort consisted of 180 patients with ulcerative colitis and 260 with Crohn's disease. Combined median follow-up was 52 weeks (interquartile range [IQR] 26-52 weeks). In ulcerative colitis, 12-month cumulative rates of clinical remission, mucosal healing, and deep remission were 57.4%, 47.3%, and 38.5%, respectively. In Crohn's disease, 12-month cumulative rates of clinical remission, mucosal healing, and deep remission were 58.4%, 38.9%, and 28.3% respectively. The serious adverse event rate was 15.6 per 100 patient-years of follow-up. CONCLUSIONS: Vedolizumab is a safe and effective treatment for achieving both clinical remission and mucosal healing in ulcerative colitis and Crohn's disease.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Fármacos Gastrointestinais/uso terapêutico , Doenças Inflamatórias Intestinais/tratamento farmacológico , Adulto , Anticorpos Monoclonais Humanizados/efeitos adversos , Proteína C-Reativa/análise , Colite Ulcerativa/tratamento farmacológico , Doença de Crohn/tratamento farmacológico , Fezes/química , Feminino , Fármacos Gastrointestinais/efeitos adversos , Humanos , Doenças Inflamatórias Intestinais/patologia , Mucosa Intestinal/patologia , Estimativa de Kaplan-Meier , Complexo Antígeno L1 Leucocitário/análise , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Escócia , Resultado do Tratamento
2.
Frontline Gastroenterol ; 6(3): 156-160, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28839805

RESUMO

OBJECTIVE: Faecal calprotectin (FC) is a non-invasive marker used to differentiate irritable bowel syndrome from inflammatory bowel disease (IBD). However, false positives are common. We sought to determine the diagnostic yield of investigation in patients presenting with new lower gastrointestinal (GI) symptoms and a mildly elevated FC (100-200 µg/g). DESIGN: Retrospective study of electronic patient records. PATIENTS: Patients aged 16-50 years with new lower GI symptoms and an FC 100-200 µg/g were identified from our biochemistry laboratory database between September 2009 and 2011. Patients were excluded if they had a previous FC >200 µg/g, were taking non-steroidal anti-inflammatory drugs (NSAIDs), had IBD, positive stool cultures or 'alarm' symptoms. SETTING: Secondary care gastroenterology clinics. RESULTS: 161 patients (103 female patients) were identified. Mean age was 37.3 years with a mean FC of 147 µg/g. 398 endoscopic, radiological and histological investigations were undertaken in 141 patients (an average of 2.8 investigations per patient). 131 colonoscopies were performed with abnormalities in only 24 (18.3%). In patients with a macroscopically normal upper GI endoscopy and colonoscopy, the diagnostic yield of any further investigation was only 7.3%. The negative predictive value (NPV) of an FC 100-200 µg/g was 86.7% for any pathology and 97.5% for significant luminal pathology (IBD, advanced adenoma or colorectal carcinoma). After a mean follow-up of 172.4 weeks, IBD was the final diagnosis in only 4 (2.5%) of patients. CONCLUSIONS: In adult patients under 50 years old presenting with new lower GI symptoms, the NPV of an FC between 100 and 200 µg/g in excluding significant organic GI disease is high.

3.
Neurogastroenterol Motil ; 24(1): 61-4, e11, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22188326

RESUMO

BACKGROUND: The high resolution esophageal manometry system manufactured by Sierra Scientific Instruments is widely used. The technology is liable to 'thermal drift', a change in measured pressure due to change in temperature. This study aims to characterize 'thermal drift' and minimize its impact. METHODS: Response of the system to immediate temperature change (20 °C to 37 °C) was tested. Accuracy of pressure measurement over two hours at 37 °C was examined. Six repetitions were performed and median pressure change calculated for each sensor. Sensors were compared using Kruskal-Wallis test. Current correction processes were tested. KEY RESULTS: There was a biphasic response of the system to body temperature: an immediate change in recorded pressure, 'thermal effect' and an ongoing pressure change with time, 'baseline drift'. Median thermal effect for all 36 sensors was 7 mmHg (IQR 3.8 mmHg). Median baseline drift was 11.1 mmHg (IQR 9.9 mmHg). Baseline drift varied between sensors but for a given sensor was linear. Interpolated thermal compensation, recommended for prolonged studies, corrects data assuming a linear drift of pressures. When pressures were corrected in this way, baseline pressure was almost restored to zero (Median 0.3 mmHg, IQR 0.3). The standard thermal compensation process did not address the error associated with baseline drift. CONCLUSIONS & INFERENCES: Thermal effect is well compensated in the current operation of the system but baseline drift is not well recognized or addressed. Incorporation of a linear correction into current software would improve accuracy without impact on ease of use.


Assuntos
Temperatura Corporal , Esôfago/fisiologia , Manometria/instrumentação , Manometria/métodos , Manometria/normas , Desenho de Equipamento , Esôfago/anatomia & histologia , Humanos , Pressão , Reprodutibilidade dos Testes , Transdutores de Pressão
4.
Scott Med J ; 56(1): 59, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21515536

RESUMO

Injecting drug users are prone to atypical infections. We present a case of septic thrombophlebitis secondary to Fusobacterium gonidiaformans infection in a heroin user, which demonstrates the frequently unusual nature of pathogens and presentations in this group of patients.


Assuntos
Infecções por Fusobacterium/complicações , Infecções por Fusobacterium/diagnóstico , Dependência de Heroína/microbiologia , Sepse/microbiologia , Tromboflebite/microbiologia , Adulto , Antibacterianos/uso terapêutico , Fusobacterium/isolamento & purificação , Infecções por Fusobacterium/tratamento farmacológico , Dependência de Heroína/complicações , Humanos , Masculino , Sepse/complicações , Sepse/diagnóstico , Abuso de Substâncias por Via Intravenosa/complicações , Tromboflebite/complicações
5.
Gut ; 58(7): 904-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19060017

RESUMO

INTRODUCTION: The proximal cardia region of the stomach has a high incidence of inflammation, metaplasia and neoplasia. It demonstrates less acid buffering following meals than the more distal stomach. Novel high definition pHmetry was employed to investigate acidity at the cardia under fasting conditions and in response to a meal. METHODS: 15 healthy subjects were studied. A custom-made 12-electrode pH catheter was clipped at the squamocolumnar junction with four electrodes recording proximal to and eight distal to the squamocolumnar junction. The most distal pH electrode was located at the catheter tip, and nine electrodes in the region of the squamocolumnar junction were 11 mm apart. RESULTS: The electrode situated in the cardia 5.5 mm distal to the squamocolumnar junction differed from all other intragastric electrodes during fasting in recording minimal acidity (pH <4 = 2.2%) while all other intragastric electrodes recorded high intragastric acidity (pH <4 =or>39%) (p<0.05). The cardia also differed from the rest of the stomach, showing a marked increase in acidity in response to the meal (from 2.2% fasting to 58.4% at 60-70 min after the meal; p<0.05) while the electrodes distal to the cardia all showed a marked decrease in acidity (p<0.05). These changes in acidity at the cardia following the meal caused the gastric acidity to extend 10 mm closer to the squamocolumnar junction. CONCLUSION: Whereas the rest of the stomach shows a marked fall in acidity on ingesting a meal, the cardia paradoxically increases in acidity to become the most acidic region throughout the postprandial period.


Assuntos
Cárdia/fisiologia , Ingestão de Alimentos/fisiologia , Ácido Gástrico/fisiologia , Período Pós-Prandial/fisiologia , Gastropatias/fisiopatologia , Adulto , Cárdia/metabolismo , Endoscopia Gastrointestinal , Monitoramento do pH Esofágico , Jejum/fisiologia , Feminino , Ácido Gástrico/metabolismo , Determinação da Acidez Gástrica/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Gastropatias/metabolismo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...