Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38928976

RESUMO

A recent study conducted in Khon Kaen Province, Thailand, evaluated the effectiveness of a technology-assisted intervention aimed at improving water quality and addressing related health issues in communities around key water bodies. The intervention targeted health concerns associated with water contamination, including chronic kidney diseases, skin conditions, hypertension, and neurological symptoms. The study included water quality assessments and health evaluations of 586 residents and implemented a Learning Innovation Platform (LIP) across 13 communities. Results showed significant improvements in the community, including a decrease in hypertension and skin-related health issues, as well as enhanced community awareness and proficiency in implementing simple water quality assessments and treatment. The study demonstrated the value of a comprehensive, technology-driven community approach, effectively enhancing water quality and health outcomes, and promoting greater community awareness and self-sufficiency in managing environmental health risks.


Assuntos
Qualidade da Água , Tailândia , Humanos , Feminino , Masculino , Adulto , Poluição da Água , Pessoa de Meia-Idade , Dermatopatias/terapia
2.
Biosensors (Basel) ; 13(9)2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37754110

RESUMO

This study presents the development of a portable fluorometer with a smartphone application designed to facilitate the early screening of chronic kidney and renal diseases by enabling the sensitive detection of urinary albumin. Utilizing a fluorescence-based aptasensor, the device achieved a linear calibration curve (0.001-1.5 mg/mL) with a linearity of up to 0.98022 and a detection limit of 0.203 µg/mL for human serum albumin (HSA). The analysis of 130 urine samples demonstrated comparable performance between this study's fluorometer, a commercial fluorometer, and the standard automated method. These findings validate the feasibility of the portable fluorometer and aptasensor combination as a reliable instrument for the sensitive and specific measurement of HSA in urine samples. Moreover, the fluorometer's portability offers potential applications in portable point-of-care testing, enhancing its utility in clinical settings for early disease screening.


Assuntos
Aplicativos Móveis , Smartphone , Humanos , Albumina Sérica Humana , Calibragem , Doença Crônica , Rim
3.
MethodsX ; 7: 101114, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33194563

RESUMO

A simple and sensitive graphene oxide-mediated fluorescence quenching aptasensor is developed to quantify albuminuria in urine samples. The developed aptasensor used the specific target binding property of aptamer and fluorescence quenching property of graphene oxide to determine the concentration of human serum albumin in urine. The limit of detection of the developed platform is 0.05 µg.mL-1 and the detection range is 0.1-600 µg.mL-1, which covers the albuminuria concentration range present in normal human urine and the urine of the patient with chronic kidney disease. This approach can be modified to measure albuminuria using a high-throughput quantification platform and portable point of care testing. In addition, the production cost for one reaction is cheaper than those for the standard automated method. Therefore, this aptasensor has significant potential for commercialization and public use.•Our protocol is customized by using the fluorescence quenching property of graphene oxide and specific binding property of human serum albumin aptamer to detect human serum albumin in urine sample•The limit of detection of our developed platform is 0.05 µg.mL-1•The detection range of our aptasensor is 0.1-600 µg.mL-1.

4.
Spectrochim Acta A Mol Biomol Spectrosc ; 231: 118128, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32066078

RESUMO

Albuminuria is a pathological condition wherein the human serum albumin (HSA) protein is present in abnormally excess amounts in the urine. A simple and sensitive graphene oxide-mediated fluorescence quenching aptasensor is developed to quantify albumin in urine samples and HSA in serum samples. The aptamer-bound HSA used in this aptasensor has hairpin structures, which are characteristic of the aptamer binding site. The limit of detection of the developed platform is 0.05 µg·mL-1 and the detection range is 0.1-14.0 µg·mL-1, which covers the albuminuria concentration range present in normal human urine and the urine of the patient with kidney diseases. This approach can be modified to measure HSA using a high-throughput quantification platform and portable point of care testing. In addition, the production cost for one reaction is cheaper than those for other standard automated methods. Therefore, this aptasensor has significant potential for commercialization and wide-scale public use.


Assuntos
Albuminúria/diagnóstico , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Grafite/química , Albumina Sérica Humana/análise , Albuminúria/sangue , Albuminúria/urina , Humanos , Limite de Detecção , Albumina Sérica Humana/urina , Espectrometria de Fluorescência/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...