Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Eur Radiol ; 29(9): 5007-5012, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30796569

RESUMO

OBJECTIVES: To evaluate technical feasibility and safety of endovascular tumor specimen sampling using an escalating endovascular biopsy strategy using a directional atherectomy device compared with forceps biopsy and catheter aspiration. MATERIALS AND METHODS: Between 2013 and 2017, a cohort of ten consecutive patients (6 male; median age 56, range 39-73 years) was referred for sampling of endovascular masses. Localizations included the abdominal aorta (n = 4), left brachiocephalic vein (n = 2), inferior vena cava (n = 1), and left pulmonary artery (n = 3). For each individual mass, all three endovascular tissue sampling approaches were applied including catheter-based aspiration, straight two-jaw biopsy forceps, and directional atherectomy during a single session. RESULTS: Aspiration and forceps biopsy did not provide sufficient material for histological analyses. In contrast, technical success for endovascular tumor sampling using directional atherectomy was 100%. After two atherectomy passages, sufficient material was available for each vessel region allowing histologic diagnosis, which revealed sarcoma and chronic inflammation for masses in the aorta, angiosarcoma for brachiocephalic vein, hepatocellular carcinoma for inferior vena cava, and angiosarcoma for pulmonary artery. In case of a histologically benign diagnosis, no malignant tumor proliferation was obvious on follow-up imaging studies after 3 months and 1 year. Thus, the rate of false-negative results was considered 0%. No procedure-associated complications, e.g., vessel perforation, were recorded. CONCLUSION: Preliminary results in a limited number of patients proved directional atherectomy beneficial as a safe and feasible technique for endoluminal tissue sampling of vascular masses. Additional large-scale studies are necessary and worthy for further evaluation in clinical practice. KEY POINTS: • Endovascular masses pose a challenge to appropriate clinical management. • Off-label directional atherectomy proved to be a safe and feasible technique for endoluminal tissue sampling of vascular masses. Furthermore, directional atherectomy was superior to aspiration or forceps biopsy in our small study cohort. • Directional atherectomy may represent the last or only option for tissue probing as a prerequisite for further treatment decisions.


Assuntos
Aterectomia/métodos , Biópsia/métodos , Neoplasias Vasculares/patologia , Adulto , Idoso , Aterectomia/instrumentação , Biópsia/instrumentação , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
3.
AJR Am J Roentgenol ; 206(3): 481-6, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26901004

RESUMO

OBJECTIVE: The purpose of this study was to prospectively compare the effect of inspiration and resting expiratory position on contrast enhancement in pulmonary CT angiography (CTA) in a randomized clinical trial. SUBJECTS AND METHODS: In accordance with a power analysis performed before the study, we included 28 consecutive patients referred for evaluation of suspected pulmonary embolism in this prospective study. Patients were randomly assigned to perform either inspiration (n = 14; six men, eight women; mean age [SD], 38.1 ± 9.8 years) or resting expiratory position (n = 14; six men, eight women; mean age: 42.1 ± 9.2 years). All patients were scanned in a standardized supine position and scanning parameters were kept constant. Contrast medium was injected automatically with bolus tracking. Objective pulmonary vessel attenuation was quantified with digital measurement. Results were analyzed by using the unpaired t test and chi-square test. RESULTS: Patients in the resting expiratory position showed significantly higher contrast attenuation than those who performed inspiration (302.9 ± 11.9 HU vs 221.5 ± 20.9 HU; p < 0.01). There were no significant differences in applied total volume of contrast agent (76.8 ± 1.9 mL vs 75.7 ± 1.6 mL; p = 0.6765), total volume including normal saline bolus (116.8 mL ± 2.8 mL vs 121.8 mL ± 2.3 mL; p = 0.1724) or flow rate (3.1 mL/s ± 0.1 mL/s vs 3.2 mL/s ± 0.1 mL/s). CONCLUSION: Pulmonary CTA should be performed in the resting expiratory position, and patients should be instructed to avoid inspiration to achieve the highest possible attenuation in the pulmonary arteries.


Assuntos
Angiografia , Pulmão/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Meios de Contraste , Expiração , Feminino , Humanos , Inalação , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia , Embolia Pulmonar/fisiopatologia
4.
Invest Radiol ; 50(12): 835-42, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26186281

RESUMO

OBJECTIVES: This study aims to compare the enhancement properties of an experimental high-relaxivity extracellular gadolinium chelate (P03277) with a standard extracellular contrast agent (gadobutrol) in vivo in a rat model of hepatic colorectal cancer metastases and in vitro by relaxometry measurements. MATERIALS AND METHODS: Ten rats with hepatic colorectal cancer metastases were examined using a 9.4 T animal scanner (Bruker, Germany). Each animal was subjected to 2 contrast-enhanced magnetic resonance imaging experiments separated by 2 days receiving 0.1 mmol/kg body weight gadobutrol and 0.1 mmol/kg body weight P03277 intravenously in a random manner. T1-weighted self-gated fast low-angle shot sequences (time to repetition/time to echo, 45/2.5 milliseconds; flip angle, 45 degrees; acquisition time, 1:23 minutes; voxel size, 0.2 × 0.2 × 1.0 mm) were acquired before and at 10 consecutive time points after contrast injection. We assessed signal-to-noise ratio (SNR) of tumor (SNRtumor) and normal liver tissue (SNRliver), contrast-to-noise ratio, and lesion enhancement (LE). In addition, relaxation rates of P03277 and gadobutrol were assessed in vitro in human plasma at 37°C at a field strength of 9.4 T.Statistical analyses included paired t tests and Wilcoxon matched pairs signed rank tests. RESULTS: SNRliver, SNRtumor, contrast-to-noise ratio, and LE were significantly higher (P < 0.05) using P03277 for all time points as compared with gadobutrol. Both agents demonstrated comparable contrast kinetics with an early peak enhancement immediately after application (initial percent LE: gadobutrol, 84%; P03277, 156%) and an early and continuous washout during the examination period (final percent LE: gadobutrol, 36%; P03277, 63%). In vitro evaluation of relaxivities demonstrated markedly higher R1 for P03277 (8.6 mM s) as compared with gadobutrol (4.2 mM s). CONCLUSIONS: This study provides the first in vivo and in vitro data of P03277, an experimental extracellular MR contrast agent. P03277 demonstrates significantly better enhancement properties as compared with gadobutrol in experimental hepatic colorectal cancer metastases. In addition, in vitro data demonstrate superior relaxivities of P03277 at a broad spectrum of different field strengths. Hence, this new agent has the potential to improve lesion conspicuity and subsequently sensitivity in diagnostic imaging for both clinical magnetic resonance imaging at 1.5 or 3 T and ultra-high field applications between 4.7 and 9.4 T.


Assuntos
Meios de Contraste , Complexos de Coordenação , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos , Animais , Neoplasias Colorretais/patologia , Modelos Animais de Doenças , Feminino , Gadolínio , Neoplasias Hepáticas/secundário , Intensificação de Imagem Radiográfica , Ratos
5.
Langenbecks Arch Surg ; 400(6): 641-59, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26088872

RESUMO

BACKGROUND: Transarterial liver-directed therapies are currently not recommended as a standard treatment for colorectal liver metastases. Transarterial chemoembolization (TACE), however, is increasingly used for patients with liver-dominant colorectal metastases after failure of surgery or systemic chemotherapy. The limited available data potentially reveals TACE as a valuable option for pre- and post-operative downsizing, minimizing time-to-surgery, and prolongation of overall survival after surgery in patients with colorectal liver only metastases. PURPOSE: In this overview, the current status of TACE for the treatment of liver-dominant colorectal liver metastases is presented. Critical comments on its rationale, technical success, complications, toxicity, and side effects as well as oncologic outcomes are discussed. The role of TACE as a valuable adjunct to surgery is addressed regarding pre- and post-operative downsizing, conversion to resectability as well as improvement of the recurrence rate after potentially curative liver resection. Additionally, the concept of TACE for liver-dominant metastatic disease with a focus on new embolization technologies is outlined. CONCLUSIONS: There is encouraging data with regard to technical success, safety, and oncologic efficacy of TACE for colorectal liver metastases. The majority of studies are non-randomized single-center series mostly after failure of systemic therapies in the 2nd line and beyond. Emerging techniques including embolization with calibrated microspheres, with or without additional cytotoxic drugs, degradable starch microspheres, and technical innovations, e.g., cone-beam computed tomography (CT) allow a new highly standardized TACE procedure. The real efficacy of TACE for colorectal liver metastases in a neoadjuvant, adjuvant, and palliative setting has now to be evaluated in prospective randomized controlled trials.


Assuntos
Antineoplásicos/administração & dosagem , Quimioembolização Terapêutica , Neoplasias Colorretais/patologia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Humanos , Infusões Intra-Arteriais
6.
Knee Surg Sports Traumatol Arthrosc ; 23(9): 2704-14, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24928370

RESUMO

PURPOSE: First, to evaluate whether medial open wedge high tibial osteotomy (HTO) induces alterations of the microstructure of the lateral tibial subchondral bone plate of sheep. Second, to test the hypothesis that specific correlations exist between topographical structural alterations of the subchondral bone, the cartilage and the lateral meniscus. METHODS: Three experimental groups received biplanar osteotomies of the right proximal tibiae: (a) closing wedge HTO (4.5° of tibial varus), (b) opening wedge HTO (4.5° tibial valgus; standard correction) and (c) opening wedge HTO (9.5° of valgus; overcorrection), each of which was compared to the non-osteotomised contralateral proximal tibiae. After 6 months, subchondral bone structure indices were measured by computed tomography. Correlations between the subchondral bone, the articular cartilage and the lateral meniscus were determined. RESULTS: Increased loading by valgus overcorrection led to an enlarged specific bone surface (BS/BV) in the subarticular spongiosa compared with unloading by varisation. The subchondral bone plate was 3.9-fold thicker in the central region of the lateral tibial plateau than in the submeniscal periphery. Its thickness in the central region significantly correlated with the thickness of the articular cartilage. In the submeniscal region, such correlation did not exist. In general, a higher degree of osteoarthritis (OA) correlated with alterations of the subchondral bone plate microstructure. OA of the submeniscal articular cartilage also correlated with worse matrix staining of the lateral meniscus. CONCLUSION: Osteoarthritis changes are associated with alterations of the subchondral bone plate microstructure. Specific topographical relationships exist in the central region between the articular cartilage and subchondral bone plate thickness, and in the submeniscal periphery between and the articular cartilage and lateral meniscus. From a clinical perspective, the combined follow-up data from this and the previous two investigations suggest that open wedge valgus HTO is a safe procedure for the lateral compartment to manage medial osteoarthritis of the knee with varus malalignment in the short term.


Assuntos
Cartilagem Articular/patologia , Articulação do Joelho/patologia , Meniscos Tibiais/patologia , Osteoartrite do Joelho/patologia , Tíbia/patologia , Doenças dos Animais , Animais , Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Meniscos Tibiais/diagnóstico por imagem , Meniscos Tibiais/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/etiologia , Osteotomia , Carneiro Doméstico , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
7.
BMC Nephrol ; 15: 163, 2014 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-25281195

RESUMO

BACKGROUND: Demineralisation and bone density loss during immobilisation are known phenomena. However information concerning the extent of calcium loss during immobilisation remains inconsistent within literature. This may explain why treatment of bone loss and prevention of further demineralisation is often initiated only when spontaneous bone fracture occurred.Continuous renal replacement therapy is commonly utilised in critically ill patients with acute kidney injury requiring RRT. Regional anticoagulation with citrate for CRRT is well-established within the intensive care setting. Due to calcium free dialysate, calcium is eliminated directly as well as indirectly via citrate binding necessitating calcium substitution. In anuric patients declining calcium requirements over time reflect bone calcium liberation secondary to immobilisation. The difference between the expected and actual need for calcium infusion corresponds to calcium release from bone which is particularly impressive in patients exposed to long-term immobilisation and CRRT. We report a dialysis period in excess of 250 days with continuous renal replacement therapy and anticoagulation with citrate. CASE PRESENTATION: We present a 30-year old male with prolonged multisystem organ failure after bilateral lung transplantation, in whom during a period of 254 days the cumulative difference between expected and actual need for calcium infusion was 14.25 mol, representing an estimated calcium loss of about 571 g. Comparison of computed tomographic imaging of the lower thoracic vertebrae over this period depicts a radiographically discernible decrease in bone density from 238 to 52 Hounsfield Units. The first spontaneous fracture occurred after 6 months of immobilisation. Despite subsequent treatment with bisphosphonates and androgen therapy resulting in an increase in bone density to 90 HU a further fracture occurred. CONCLUSION: In immobilised patients receiving CRRT and anticoagulation with citrate, decreasing need for calcium substitution reflects the degree of bone demineralisation corresponding with radiographic assessment of declining bone mineral density. Such a declining need for calcium substitution could be useful in clinical practice highlighting relevant bone loss which results in spontaneous fractures in immobilised critically ill patients.


Assuntos
Repouso em Cama/efeitos adversos , Cálcio/uso terapêutico , Distúrbio Mineral e Ósseo na Doença Renal Crônica/tratamento farmacológico , Hemofiltração/efeitos adversos , Complicações Pós-Operatórias/tratamento farmacológico , Adulto , Anticoagulantes/uso terapêutico , Conservadores da Densidade Óssea/uso terapêutico , Cálcio/administração & dosagem , Cálcio/sangue , Distúrbio Mineral e Ósseo na Doença Renal Crônica/sangue , Distúrbio Mineral e Ósseo na Doença Renal Crônica/etiologia , Citratos/uso terapêutico , Fibrose Cística/cirurgia , Difosfonatos/uso terapêutico , Progressão da Doença , Relação Dose-Resposta a Droga , Evolução Fatal , Fraturas Espontâneas/etiologia , Humanos , Transplante de Pulmão , Masculino , Insuficiência de Múltiplos Órgãos/etiologia , Hormônio Paratireóideo/sangue , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/terapia , Reoperação , Testosterona/uso terapêutico , Vitamina D/sangue
8.
World J Surg Oncol ; 12: 198, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24980217

RESUMO

Intra- or extrahepatic cholangiocarcinomas are the second most common primary liver malignancies behind hepatocellular carcinoma. Whereas the incidence for intrahepatic cholangiocarcinoma is rising, the occurrence of extrahepatic cholangiocarcinoma is trending downwards. The treatment of choice for intrahepatic cholangiocarcinoma remains liver resection. However, a case of liver resection after selective internal radiation therapy in order to treat a recurrent intrahepatic cholangiocarcinoma in a transplant liver is unknown in the literature so far. Herein, we present a case of a patient undergoing liver transplantation for Wilson's disease with an accidental finding of an intrahepatic cholangiocarcinoma within the explanted liver. Due to a recurrent intrahepatic cholangiocarcinoma after liver transplantation, a selective internal radiation therapy with yttrium-90 microspheres was performed followed by right hemihepatectomy. Four years later, the patient is tumor-free and in a healthy condition.


Assuntos
Neoplasias dos Ductos Biliares/terapia , Braquiterapia , Carcinoma Hepatocelular/complicações , Colangiocarcinoma/terapia , Hepatectomia , Degeneração Hepatolenticular/complicações , Neoplasias Hepáticas/complicações , Transplante de Fígado/efeitos adversos , Neoplasias dos Ductos Biliares/diagnóstico , Neoplasias dos Ductos Biliares/etiologia , Ductos Biliares Intra-Hepáticos/patologia , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/cirurgia , Colangiocarcinoma/diagnóstico , Colangiocarcinoma/etiologia , Terapia Combinada , Embolização Terapêutica , Degeneração Hepatolenticular/diagnóstico , Degeneração Hepatolenticular/cirurgia , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/cirurgia , Microesferas , Pessoa de Meia-Idade , Prognóstico , Radioisótopos de Ítrio/uso terapêutico
9.
Invest Radiol ; 48(10): 738-44, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23695083

RESUMO

OBJECTIVE: The aim of this study was to compare a retrospectively self-gated fast low angle shot sequence (RSG-FLASH) with a prospectively triggered fast low angle shot sequence (PT-FLASH) using an external trigger device for dynamic contrast-enhanced magnetic resonance imaging of the liver at 9.4 T in a rat model of colorectal cancer metastases. MATERIALS AND METHODS: In 10 rats with hepatic metastases, we acquired an axial RSG-FLASH sequence through the liver. A FLASH sequence with prospective triggering (PT-FLASH) using an external trigger device was acquired at the same location with the same imaging parameters. After intravenous injection of 0.2 mmol/kg body weight of Gd-DTPA, alternating acquisitions of both sequences were performed at 4 consecutive time points.Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion enhancement were obtained for liver tumors and parenchyma. In addition, we assessed the total acquisition times of the different imaging approaches for each acquisition, including triggering and gating. Two independent readers performed a qualitative evaluation of each sequence. Statistical analyses included paired t tests and Wilcoxon matched pairs signed rank tests. RESULTS: No statistically significant differences in SNR, CNR, or lesion enhancement were observed. Qualitative assessments of the sequences were comparable. However, acquisition times of PT-FLASH were significantly longer (mean [SD], 160.6 [25.7] seconds; P < 0.0001) and markedly variable (minimum, 120 seconds; maximum, 209 seconds), whereas the RSG-FLASH approach demonstrated a constant mean (SD) acquisition time of 59.0 (0) seconds. CONCLUSIONS: The RSG-FLASH and PT-FLASH sequences do not differ qualitatively or quantitatively regarding SNR, CNR, and lesion enhancement for magnetic resonance imaging of the liver in the rats at 9.4 T. However, the variability of acquisition times for the PT-FLASH sequences is a major factor of inconsistency, and we therefore consider this approach as inappropriate for dynamic contrast-enhanced studies with multiple-measurement time points. In contrast, the RSG-FLASH sequence represents a fast, consistent, and reproducible technique suitable for contrast-agent kinetic studies in experimental small-animal imaging of the abdomen.


Assuntos
Neoplasias Colorretais/patologia , Modelos Animais de Doenças , Gadolínio DTPA , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Técnicas de Imagem de Sincronização Respiratória/métodos , Algoritmos , Animais , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Langenbecks Arch Surg ; 397(5): 763-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22426638

RESUMO

PURPOSE: Surgeons frequently describe the shape of intraoperative findings using visual judgement and their own sense of proportion or describing these findings in comparison to commonly used or metaphoric subjects. The aim of the study was to analyse the reliability of surgeon's estimations of dimensions. METHODS: The study was performed in two phases. First, physicians had to estimate the metric proportions of four well-known objects. Second, surgeons were asked intraoperatively to estimate the liver resection surface after partial hepatectomy. The exact surface of the resection plane was measured using computed tomography-guided planimetry of the resection specimen. Physician's estimations and the exact measurements of the well-known objects and the liver resection surface were compared. Systematic error was defined by the natural logarithm of estimated/real size. RESULTS: We found a large individual discrepancy in estimating the metric proportions of commonly used objects and a tendency to underestimate both commonly used objects and liver resection surface. Experienced liver surgeons were more accurate in estimating liver resection surface compared with younger staff members. CONCLUSIONS: We found a large bias in estimating the dimension of both commonly used objects and the surface area of liver parenchyma transection. Obviously, estimating errors are more influenced by the individual subject who estimates than by the object itself. In clinical routine, surgeons should rely more on simple measuring devices than on their own sense of proportion. Education in how to estimate more correctly human liver resection surfaces can be achieved by ex vivo studies using porcine livers.


Assuntos
Hepatectomia/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Fígado/diagnóstico por imagem , Fígado/patologia , Competência Clínica , Estudos de Coortes , Tomada de Decisões , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Procedimentos Cirúrgicos do Sistema Digestório/normas , Feminino , Hepatectomia/normas , Humanos , Período Intraoperatório , Neoplasias Hepáticas/patologia , Masculino , Erros Médicos , Tamanho do Órgão , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Propriedades de Superfície , Inquéritos e Questionários , Carga Tumoral
11.
Invest Radiol ; 47(4): 259-66, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22373534

RESUMO

OBJECTIVE: A critical problem in cardiovascular MRI in small rodents is adjusting the sequence acquisition to the high heart and respiratory rates. The aim of this study was to compare a retrospectively self-gated fast low angle shot navigator (RSG-FLASH) sequence with a conventional prospectively triggered (PT-FLASH) sequence for cine imaging of the ascending aorta in mice at 9.4 T. MATERIAL AND METHODS: Ten C57/BL6 mice were examined with a horizontal bore 9.4 Tesla MRI animal scanner using a dedicated 2 × 2 phased-array surface coil. We acquired a RSG-FLASH sequence (RSG-FLASH sequences (repetition time (TR) / echo time (TE) = 6.5/2.5 ms, flip angle (FA) = 10 degrees, field of view (FOV) = 2 × 2 cm, matrix = 384 × 384, slice thickness = 1 mm, 25 movie frames) perpendicular to the ascending aorta using the IntraGate technique. At the same position, we performed a PT-FLASH sequence (TR/TE = 6.5/2.1 ms, FA = 10 degrees, FOV = 2 × 2 cm, matrix = 384 × 384, slice thickness = 1 mm) in which the maximum number of movie frames had to be adjusted to the interval between two R-peaks (RR interval) of the electrocardiogram (ECG) with: number of frames = RR interval / TR." Cross-sectional vessel areas at end-systole (AES) and end-diastole (AED) were measured to determine the aortic strain (ΔA = (AES-AED)/AED). Two blinded readers rated the sequences for presence of flow and trigger artifacts and their influence on the depiction of the blood/vessel-wall interface. Irregularities in displaying the cardiac cycle and the overall suitability of the sequence for aortic strain evaluation were assessed using a 5-level ordinal scale. Statistical differences were analyzed using Student t test and Wilcoxon signed rank test (P < 0.05). Intra- and interobserver variability was evaluated using Bland-Altman analyses. RESULTS: No significant differences were noted between techniques regarding the measured vessel areas (AED: P = 0.07, AES: P = 0.34), ΔA: P = 0.1). Similarly, there were no significant differences in heart (P = 0.06) and respiratory (P = 0.24) rates. The acquisition time for RSG-FLASH sequence was significantly shorter (P = 0.04). Significantly fewer flow and trigger artifacts were noted by both readers with the RSG-FLASH sequence. Likewise, both readers considered the RSG-FLASH sequence to be superior for depiction of the blood/vessel-wall interface. The RSG-FLASH sequence was also rated superior regarding irregularities in displaying the cardiac cycle and in terms of overall suitability for evaluation of AED, AES, and aortic strain (P < 0.05 each). CONCLUSION: RSG-FLASH is preferable for cine imaging of the aorta. It provides the same quantitative data as PT-FLASH cine imaging but is less prone to flow and trigger artifacts. RSG-FLASH permits more homogeneous depiction of the cardiac cycle and is faster than the PT-FLASH sequence. PT-FLASH is more prone to misregistration of the respiratory cycle or the ECG by the external monitoring device used for acquisition. This effect may be even more pronounced in animals with disease models that are less stable in terms of heart and respiration rate during anesthesia.


Assuntos
Aorta/anatomia & histologia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Animais , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
12.
Int Surg ; 96(2): 117-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22026301

RESUMO

A 49-year-old woman presented with acute abdominal pain in the right iliac fossa in our emergency department. Pain was abrupt in onset and severely colicky in nature. Abnormal laboratory values included a C-reactive protein of 75 mg/L and a CA-125 of 70.3 U/mL. White blood cell count was normal. Abdominal computed tomography (CT) scan revealed an inhomogeneous mass of 9.5 x 3.5 x 5.5 cm in diameter close to the appendix vermiformis and the sigmoid colon. Because of the clinical symptoms of an acute abdomen an explorative laparotomy was performed. Intraoperatively a pedunculated tumor beginning at the serosa of the sigmoid colon was found. The appendix was unremarkable. The macroscopic aspect as well as the backtable incision of the tumor was suspicious of an intraperitoneal liposarcoma. Rapid section and histopathologic examination revealed necrotic fat tissue without any malignancy. The patient was discharged from the hospital 7 days after the operation with normal laboratory parameters and without further complication. When epiploic appendagitis is evident as a big tumor mass in addition to clinical symptoms of an acute abdomen and elevated tumor markers, surgical exploration is mandatory.


Assuntos
Lipossarcoma/diagnóstico , Neoplasias Peritoneais/diagnóstico , Doenças do Colo Sigmoide/diagnóstico , Doenças do Colo Sigmoide/cirurgia , Tecido Adiposo/patologia , Eletrocoagulação , Feminino , Humanos , Pessoa de Meia-Idade , Necrose , Doenças do Colo Sigmoide/diagnóstico por imagem , Doenças do Colo Sigmoide/patologia , Tomografia Computadorizada por Raios X
13.
Eur Radiol ; 17(5): 1380-3, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17356842

RESUMO

Biliary cystadenoma is a rare epithelial cystic neoplasm representing only 5% of intrahepatic cystic lesions of biliary origin. Commonly, the lesions are solitary cystic structures with multiple thin-walled septa predominantly arising from the right hepatic duct. Although the lesions are generally intrahepatic, extrahepatic tumors have been reported. Biliary cystadenomas range in diameter from 1.5 to 35 cm. The tumor usually affects middle-aged women. Clinical symptoms are related to the mass effect and comprise episodes of jaundice due to biliary obstruction and intermittent upper abdominal pain. Laboratory parameters are nonspecific. As the tumor is considered a premalignant lesion, complete surgical resection is the treatment of choice. We report a case of typical biliary cystadenoma of the left hepatic duct.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico , Ductos Biliares Intra-Hepáticos , Cistadenoma/diagnóstico , Imageamento por Ressonância Magnética , Adulto , Neoplasias dos Ductos Biliares/cirurgia , Meios de Contraste , Cistadenoma/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Meglumina/análogos & derivados , Compostos Organometálicos
14.
Invest Radiol ; 42(2): 105-15, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17220728

RESUMO

OBJECTIVE: We sought to evaluate gadobenate dimeglumine for the detection and characterization of focal liver lesions in the unenhanced and already pre-enhanced liver. MATERIALS AND METHODS: Sixty patients were evaluated prospectively. Unenhanced T1-weighted gradient echo (T1wGRE) and T2-weighted turbo spin echo (T2wTSE) images were acquired followed by contrast-enhanced T1wGRE images during the dynamic, equilibrium, and delayed phases after the bolus injection of 0.05 mmol/kg gadobenate dimeglumine. An identical series of dynamic images was then acquired after the delayed scan following a second 0.05 mmol/kg bolus of gadobenate dimeglumine. Images were evaluated randomly in 2 sessions by 3 independent blinded readers. Evaluated images in the first session comprised the unenhanced images, the first or second set of dynamic images, and the delayed images. The second session included the unenhanced images, the dynamic images not yet evaluated in the first session, and the delayed images. The 2 reading sessions were compared for lesion characterization and diagnosis, and kappa (kappa) values for interobserver agreement were determined. Quantitative evaluation of lesion contrast enhancement was also performed. RESULTS: The enhancement behavior in the second dynamic series was similar to that in the first series, although pre-enhancement of the normal liver resulted in reduced lesion-liver contrast-to-noise ratios and the visualization of some lesions only on arterial phase images. Typical imaging features for the lesions included in the study were visualized clearly in both series. Strong agreement (kappa=0.56-0.89; all evaluations) between the 2 images sets was noted by all readers for differentiation of benign from malignant lesions and for definition of specific diagnosis, and between readers for diagnoses established based on images acquired in the unenhanced and pre-enhanced liver. CONCLUSION: Dynamic imaging in the hepatobiliary phase gives similar information as dynamic imaging of the unenhanced liver. This might prove advantageous for screening protocols involving same session imaging of primary extrahepatic tumors and liver.


Assuntos
Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Neoplasias Hepáticas/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/administração & dosagem , Adulto , Idoso , Feminino , Humanos , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
15.
Ann Surg Oncol ; 12(4): 303-12, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15827680

RESUMO

BACKGROUND: Tissue destruction by cryosurgery not only is mediated by direct cell damage, but also involves secondary mechanisms, such as ischemia due to shutdown of the microcirculation. Clinicians favor repetitive cryoapplication, although there is no proven evidence for a more effective tumor eradication. METHODS: The aims of this study were (1) to establish a rat liver tumor model that allows for intravital microscopic analysis of hepatic tumor microcirculation and (2) to elucidate critical determinants of shutdown of microvascular perfusion after single and repetitive cryotherapy. In WAG-Rji rats (n = 14), syngeneic colon carcinoma cells (CC531) were implanted into the left liver lobe. Hepatic and tumor microcirculation were studied by intravital microscopy. RESULTS: Two weeks after implantation, the tumors had developed a microvasculature with a capillary density markedly (P < .05) lower compared with the sinusoidal density of normal liver. However, at the tumor margin, venule diameters were significantly enlarged (P < .05), with high red blood cell velocities and arteriolovenular shunts. Both freeze procedures (temperature at the tumor margin: -32.4 degrees C +/- 1.6 degrees C and -36.4 degrees C +/- 2.0 degrees C) resulted in a complete shutdown of intratumoral and peritumoral capillary and hepatic sinusoidal perfusion. In contrast, some large venules showed maintenance of blood flow initially after freezing (15 minutes); however, this was abolished during the subsequent 2-hour observation period. CONCLUSIONS: Enlarged high-flow venules at the tumor margin, which participate in arteriolovenular shunting, critically determine the shutdown of the microcirculation upon cryotherapy. Repetitive freezing is not more effective than a single-freeze procedure to achieve complete tumor microcirculatory stasis.


Assuntos
Anastomose Arteriovenosa , Neoplasias do Colo/patologia , Criocirurgia/métodos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/cirurgia , Animais , Modelos Animais de Doenças , Neoplasias Hepáticas/secundário , Masculino , Microcirculação , Microscopia de Fluorescência , Ratos , Ratos Endogâmicos , Ratos Wistar , Células Tumorais Cultivadas
16.
Top Magn Reson Imaging ; 14(5): 386-402, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14625467

RESUMO

Since its introduction in the early 1990s, contrast-enhanced (CE) cardiac magnetic resonance imaging (MRI) has evolved rapidly for the assessment of cardiac pathologies, including in particular ischemic heart disease and inflammatory conditions. Likewise, CE-magnetic resonance angiography (MRA) is now used routinely to evaluate the thoracic vasculature. This article reviews the current use of extracellular gadolinium-based agents in CE cardiovascular imaging, focusing on ischemic heart disease, inflammatory myocardial conditions, and the use of CE-MRA in imaging of the pulmonary and aortic vasculature. Recent advances in fast and ultrafast MRI combined with the use of extracellular contrast media allow noninvasive measurements of multiple parameters of the cardiovascular system in less than 40 minutes. Beyond the assessment of left ventricular wall motion and morphology, CE cardiac MRI allows depiction of myocardial perfusion and thereby provides information regarding microvascular integrity and myocardial viability. The excellent spatial resolution of MRI, especially for the distinction of nontransmural versus transmural extent of pathology, has been shown to be superior to other modalities that are often nonlocalizing, nonspecific, or more invasive. Additional advantages of CE-MRA, particularly for the thoracic vasculature, include safety, its noninvasive character, large field of view, and the ability to demonstrate complicated three-dimensional relationships without the need for iodinated, nephrotoxic contrast media.


Assuntos
Meios de Contraste , Cardiopatias/diagnóstico , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Aorta Torácica/anormalidades , Aorta Torácica/patologia , Vasos Coronários/patologia , Coração/fisiopatologia , Cardiopatias/patologia , Cardiopatias/fisiopatologia , Humanos , Angiografia por Ressonância Magnética , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/patologia , Isquemia Miocárdica/fisiopatologia , Miocardite/diagnóstico , Miocárdio/patologia , Pericardite/diagnóstico , Embolia Pulmonar/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...