Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Placenta ; 150: 72-79, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38615536

RESUMO

INTRODUCTION: Proper placental development is crucial to fetal health but is challenging to functionally assess non-invasively and is thus poorly characterized in populations. Body mass index (BMI) has been linked with adverse outcomes, but the causative mechanism is uncertain. Velocity-selective arterial spin labeling (VS-ASL) MRI provides a method to non-invasively measure placental perfusion with robustness to confounding transit time delays. In this study, we report on the measurement of perfusion in the human placenta in early pregnancy using velocity-selective arterial spin labeling (VS-ASL) MRI, comparing non-obese and obese participants. METHODS: Participants (N = 97) undergoing routine prenatal care were recruited and imaged with structural and VS-ASL perfusion MRI at 15 and 21 weeks gestation. Resulting perfusion images were analyzed with respect to obesity based on BMI, gestational age, and the presence of adverse outcomes. RESULTS: At 15 weeks gestation BMI was not associated with placental perfusion or perfusion heterogeneity. However, at 21 weeks gestation BMI was associated with higher placental perfusion (p < 0.01) and a decrease in perfusion heterogeneity (p < 0.05). In alignment with past studies, perfusion values were also higher at 21 weeks compared to 15 weeks gestation. In a small cohort of participants with adverse outcomes, at 21 weeks lower perfusion was observed compared to participants with uncomplicated pregnancies. DISCUSSION: These results suggest low placental perfusion in the early second trimester may not be the culpable factor driving associations of obesity with adverse outcomes.


Assuntos
Índice de Massa Corporal , Obesidade , Placenta , Segundo Trimestre da Gravidez , Marcadores de Spin , Humanos , Feminino , Gravidez , Placenta/diagnóstico por imagem , Placenta/irrigação sanguínea , Adulto , Obesidade/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Circulação Placentária/fisiologia , Adulto Jovem
2.
J Magn Reson Imaging ; 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38375996

RESUMO

BACKGROUND: Recently, dynamic contrast-enhanced (DCE) MRI with ferumoxytol as contrast agent has recently been introduced for the noninvasive assessment of placental structure and function throughout. However, it has not been demonstrated under pathological conditions. PURPOSE: To measure cotyledon-specific rhesus macaque maternal placental blood flow using ferumoxytol DCE MRI in a novel animal model for local placental injury. STUDY TYPE: Prospective animal model. SUBJECTS: Placental injections of Tisseel (three with 0.5 mL and two with 1.5 mL), monocyte chemoattractant protein 1 (three with 100 µg), and three with saline as controls were performed in a total of 11 rhesus macaque pregnancies at approximate gestational day (GD 101). DCE MRI scans were performed prior (GD 100) and after (GD 115 and GD 145) the injection (term = GD 165). FIELD STRENGTH/SEQUENCE: 3 T, T1-weighted spoiled gradient echo sequence (product sequence, DISCO). ASSESSMENT: Source images were inspected for motion artefacts from the mother or fetus. Placenta segmentation and DCE processing were performed for the dynamic image series to measure cotyledon specific volume, flow, and normalized flow. Overall placental histopathology was conducted for controls, Tisseel, and MCP-1 animals and regions of tissue infarctions and necrosis were documented. Visual inspections for potential necrotic tissue were conducted for the two Tisseelx3 animals. STATISTICAL TESTS: Wilcoxon rank sum test, significance level P < 0.05. RESULTS: No motion artefacts were observed. For the group treated with 1.5 mL of Tisseel, significantly lower cotyledon volume, flow, and normalized flow per cotyledon were observed for the third gestational time point of imaging (day ~145), with mean normalized flow of 0.53 minute-1 . Preliminary histopathological analysis shows areas of tissue necrosis from a selected cotyledon in one Tisseel-treated (single dose) animal and both Tisseelx3 (triple dose) animals. DATA CONCLUSION: This study demonstrates the feasibility of cotyledon-specific functional analysis at multiple gestational time points and injury detection in a placental rhesus macaque model through ferumoxytol-enhanced DCE MRI. LEVEL OF EVIDENCE: NA TECHNICAL EFFICACY: Stage 2.

3.
Magn Reson Med ; 91(5): 1994-2009, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38174601

RESUMO

PURPOSE: Traditional phase-contrast MRI is affected by displacement artifacts caused by non-synchronized spatial- and velocity-encoding time points. The resulting inaccurate velocity maps can affect the accuracy of derived hemodynamic parameters. This study proposes and characterizes a 3D radial phase-contrast UTE (PC-UTE) sequence to reduce displacement artifacts. Furthermore, it investigates the displacement of a standard Cartesian flow sequence by utilizing a displacement-free synchronized-single-point-imaging MR sequence (SYNC-SPI) that requires clinically prohibitively long acquisition times. METHODS: 3D flow data was acquired at 3T at three different constant flow rates and varying spatial resolutions in a stenotic aorta phantom using the proposed PC-UTE, a Cartesian flow sequence, and a SYNC-SPI sequence as reference. Expected displacement artifacts were calculated from gradient timing waveforms and compared to displacement values measured in the in vitro flow experiments. RESULTS: The PC-UTE sequence reduces displacement and intravoxel dephasing, leading to decreased geometric distortions and signal cancellations in magnitude images, and more spatially accurate velocity quantification compared to the Cartesian flow acquisitions; errors increase with velocity and higher spatial resolution. CONCLUSION: PC-UTE MRI can measure velocity vector fields with greater accuracy than Cartesian acquisitions (although pulsatile fields were not studied) and shorter scan times than SYNC-SPI. As such, this approach is superior to traditional Cartesian 3D and 4D flow MRI when spatial misrepresentations cannot be tolerated, for example, when computational fluid dynamics simulations are compared to or combined with in vitro or in vivo measurements, or regional parameters such as wall shear stress are of interest.


Assuntos
Estenose da Valva Aórtica , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Hemodinâmica , Imagens de Fantasmas , Artefatos , Velocidade do Fluxo Sanguíneo , Imageamento Tridimensional/métodos
4.
Biol Reprod ; 107(6): 1517-1527, 2022 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-36018823

RESUMO

Identification of placental dysfunction in early pregnancy with noninvasive imaging could be a valuable tool for assessing maternal and fetal risk. Dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) can be a powerful tool for interrogating placenta health. After inoculation with Zika virus or sham inoculation at gestation age (GA) 45 or 55 days, animals were imaged up to three times at GA65, GA100, and GA145. DCE MRI images were acquired at all imaging sessions using ferumoxytol, an iron nanoparticle-based contrast agent, and analyzed for placental intervillous blood flow, number of perfusion domains, and perfusion domain volume. Cesarean section was performed at GA155, and the placenta was photographed and dissected for histopathology. Photographs were used to align cotyledons with estimated perfusion domains from MRI, allowing comparison of estimated cotyledon volume to pathology. Monkeys were separated into high and low pathology groups based on the average number of pathologies present in the placenta. Perfusion domain flow, volume, and number increased through gestation, and total blood flow increased with gestation for both low pathology and high pathology groups. A statistically significant decrease in perfusion domain volume associated with pathology was detected at all gestational ages. Individual perfusion domain flow comparisons demonstrated a statistically significant decrease with pathology at GA100 and GA145, but not GA65. Since ferumoxytol is currently used to treat anemia during human pregnancy and as an off-label MRI contrast agent, future transition of this work to human pregnancy may be possible.


Assuntos
Infecção por Zika virus , Zika virus , Animais , Gravidez , Feminino , Humanos , Lactente , Placenta/irrigação sanguínea , Óxido Ferroso-Férrico , Macaca mulatta , Meios de Contraste , Cotilédone , Cesárea , Imageamento por Ressonância Magnética/métodos , Perfusão , Infecção por Zika virus/patologia
5.
Function (Oxf) ; 3(4): zqac022, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35774590

RESUMO

Deep phenotyping of pulmonary hypertension (PH) with multimodal diagnostic exercise interventions can lead to early focused therapeutic interventions. Herein, we report methods to simultaneously assess pulmonary impedance, differential biventricular myocardial strain, and right ventricular:pulmonary arterial (RV:PA) uncoupling during exercise, which we pilot in subjects with suspected PH. As proof-of-concept, we show that four subjects with different diagnoses [pulmonary arterial hypertension (PAH); chronic thromboembolic disease (CTEPH); PH due to heart failure with preserved ejection fraction (PH-HFpEF); and noncardiac dyspnea (NCD)] have distinct patterns of response to exercise. RV:PA coupling assessment with exercise was highest-to-lowest in this order: PAH > CTEPH > PH-HFpEF > NCD. Input impedance (Z0) with exercise was highest in precapillary PH (PAH, CTEPH), followed by PH-HFpEF and NCD. Characteristic impedance (ZC) tended to decline with exercise, except for the PH-HFpEF subject (initial Zc increase at moderate workload with subsequent decrease at higher workload with augmentation in cardiac output). Differential myocardial strain was normal in PAH, CTEPH, and NCD subjects and lower in the PH-HFpEF subject in the interventricular septum. The combination of these metrics allowed novel insights into mechanisms of RV:PA uncoupling. For example, while the PH-HFpEF subject had hemodynamics comparable to the NCD subject at rest, with exercise coupling dropped precipitously, which can be attributed (by decreased myocardial strain of interventricular septum) to poor support from the left ventricle (LV). We conclude that this deep phenotyping approach may distinguish afterload sensitive vs. LV-dependent mechanisms of RV:PA uncoupling in PH, which may lead to novel therapeutically relevant insights.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Doenças não Transmissíveis , Hipertensão Arterial Pulmonar , Humanos , Artéria Pulmonar , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração , Volume Sistólico , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar Primária Familiar
6.
Int J Comput Assist Radiol Surg ; 17(1): 199-210, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34403045

RESUMO

PURPOSE: Despite the great potential and flexibility of 4D flow MRI for hemodynamic analysis, a major limitation is the need for time-consuming and user-dependent post-processing. We propose a fast four-step algorithm for rapid, robust, and repeatable flow measurements in the great vessels based on automatic placement of measurement planes and vessel segmentation. METHODS: Our algorithm works by (1) subsampling the 3D image into 3D patches, (2) predicting the probability of each patch containing individual vessels and location/orientation of the vessel within the patch via a convolutional neural network, (3) selecting the predicted planes with highest probabilities for each vessel, and (4) shifting the plane centers to the maximum velocity within each plane. The method was trained on 283 scans and evaluated on 40 unseen scans by comparing algorithm-derived processing times, plane locations, and flow measurements to those of two manual observers (graduate students) using t-tests, Pearson correlation, and Bland-Altman analysis. RESULTS: The average processing time for the algorithm (18 s) was shorter than observer 1 (362 s; P < 0.001) and observer 2 (317 s; P < 0.001). The distance between planes placed by the algorithm and those placed by manual observers was slightly greater (O1 vs. algorithm: 9.0 mm, O2 vs. algorithm: 10.3 mm) than the distance between planes placed by the two manual observers (8.3 mm). The correlation between flow values for planes placed by the algorithm and those placed by manual observers was slightly lower (O1 vs. algorithm: R = 0.68, O2 vs. algorithm: R = 0.72) than the flow correlation between the two manual observers (R = 0.81). CONCLUSION: Our method is a feasible and accurate approach for fast, reproducible, and automated flow measurement and visualization in 4D flow MRI of the great vessels, with similar variability compared to a manual annotator as the variability between two manual observers. This approach could be applied in other anatomical regions.


Assuntos
Aprendizado Profundo , Algoritmos , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Reprodutibilidade dos Testes
7.
Phys Med Biol ; 66(10)2021 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-33770774

RESUMO

Built on top of the Geant4 toolkit, GATE is collaboratively developed for more than 15 years to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular, used by researchers and industrials to design, optimize, understand and create innovative emission tomography systems. In this paper, we reviewed the recent developments that have been proposed to simulate modern detectors and provide a comprehensive report on imaging systems that have been simulated and evaluated in GATE. Additionally, some methodological developments that are not specific for imaging but that can improve detector modeling and provide computation time gains, such as Variance Reduction Techniques and Artificial Intelligence integration, are described and discussed.


Assuntos
Inteligência Artificial , Software , Simulação por Computador , Método de Monte Carlo , Tomografia Computadorizada por Raios X
8.
Med Phys ; 45(5): 2179-2185, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29480927

RESUMO

PURPOSE: Genomic profiling of biopsied tissue is the basis for precision cancer therapy. However, biopsied materials may not contain sufficient amounts of tumor deoxyribonucleonic acid needed for the analysis. We propose a method to determine the adequacy of specimens for performing genomic profiling by quantifying their metabolic activity. METHODS: We estimated the average density of tumor cells in biopsy specimens needed to successfully perform genomic analysis following the Memorial Sloan Kettering Integrated Mutation Profiling of Actionable Cancer Targets (MSK-IMPACT) protocol from the minimum amount of deoxyribonucleonic acid needed and the volume of tissue typically used for analysis. The average 18 F-FDG uptake per cell was assessed by incubating HT-29 adenocarcinoma tumor cells in 18 F-FDG containing solution and then measuring their activity with a scintillation well counter. Consequently, we evaluated the response of two devices around the minimum expected activities which would indicate genomic profiling adequacy of biopsy specimens obtained under 18 F-FDG PET/CT guidance. Surrogate samples obtained using 18G core needle biopsies of gels containing either 18 F-FDG-loaded cells in the expected concentrations or the corresponding activity were measured using autoradiography and a scintillation well counter. Autoradiography was performed using a CCD-based device with real-time image display as well as with digital autoradiography imaging plates following a 30-min off-line protocol for specimen activity determination against previously established calibration. RESULTS: Cell incubation experiments and estimates obtained from quantitative autoradiography of biopsy specimens (QABS) indicate that specimens acquired under 18 F-FDG PET/CT guidance that contained the minimum amount of cells needed for genomic profiling would have an average activity concentration in the range of about 3 to about 9 kBq/mL. When exposed to specimens with similar activity concentration, both a CCD-based autoradiography device and a scintillation well counter produced signals with sufficient signal-to-background ratio for specimen genomic adequacy identification in less than 10 min, which is short enough to allow procedure guidance. CONCLUSION: Scintillation well counter measurements and CCD-based autoradiography have adequate sensitivity to detect the tumor burden needed for genomic profiling during 18 F-FDG PET/CT-guided 18G core needle biopsies of liver adenocarcinoma metastases.


Assuntos
Autorradiografia/instrumentação , Fluordesoxiglucose F18 , Genômica , Biópsia Guiada por Imagem/instrumentação , Contagem de Cintilação/instrumentação , Transporte Biológico , Estudos de Viabilidade , Fluordesoxiglucose F18/metabolismo , Células HT29 , Humanos , Injeções , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...