Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; : e14439, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-39031633

RESUMO

BACKGROUND: Coincidence of the treatment and imaging isocenter coordinates is required to safely perform small-margin treatments, such as stereotactic radiosurgery of multiple brain metastases. A comprehensive and direct methodology for verifying concordance of kilovoltage cone-beam computed tomography (kV-CBCT) and treatment coordinates using an x-ray CT-based polymer gel dosimeter (dGEL) and onboard kV-CBCT was previously reported. Using this methodology, we tested the ability of a new commercially available x-ray CT-based polymer dGEL with a rapid response to provide efficient quality assurance (QA). PURPOSE: The aim of this study was to evaluate the robustness of the three-dimensional geometric QA methodology using dGEL. METHODS: The dGEL were commercially manufactured. The prescribed dose for each field was determined by visually identifying the 5, 10, and 20 Gy isodose lines. A linear accelerator was used to irradiate the gels with seven non-coplanar beams. An in-house analysis program was used to identify the beam axes and treatment isocenter in kV-CBCT coordinates by processing the pre- and post-irradiation CBCT images. The impact of the radiation dose on the test reproducibility was examined, and the detectability of an intentional geometric error was assessed. RESULTS: The treatment isocenter was within 0.4 mm of the imaging isocenter for all radiation doses. The residual error of the test with the intentional error was within 0.2 mm. The analysis and image quality variations for a single dGEL introduced displacement errors less than 0.3 mm. CONCLUSIONS: The test assessed the coincidence of treatment and kV-CBCT isocenter coordinates and detected errors with high robustness. Even for a 10 Gy dose, the test yielded results comparable with those obtained using higher radiation doses owing to the rapid response of the dGEL dosimeter.

2.
PLoS One ; 18(1): e0280076, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36607999

RESUMO

In urethra-sparing radiation therapy, prostatic urinary tract visualization is important in decreasing the urinary side effect. A methodology has been developed to visualize the prostatic urinary tract using post-urination magnetic resonance imaging (PU-MRI) without a urethral catheter. This study investigated whether the combination of PU-MRI and super-resolution (SR) deep learning models improves the visibility of the prostatic urinary tract. We enrolled 30 patients who had previously undergone real-time-image-gated spot scanning proton therapy by insertion of fiducial markers. PU-MRI was performed using a non-contrast high-resolution two-dimensional T2-weighted turbo spin-echo imaging sequence. Four different SR deep learning models were used: the enhanced deep SR network (EDSR), widely activated SR network (WDSR), SR generative adversarial network (SRGAN), and residual dense network (RDN). The complex wavelet structural similarity index measure (CW-SSIM) was used to quantitatively assess the performance of the proposed SR images compared to PU-MRI. Two radiation oncologists used a 1-to-5 scale to subjectively evaluate the visibility of the prostatic urinary tract. Cohen's weighted kappa (k) was used as a measure of agreement of inter-operator reliability. The mean CW-SSIM in EDSR, WDSR, SRGAN, and RDN was 99.86%, 99.89%, 99.30%, and 99.67%, respectively. The mean prostatic urinary tract visibility scores of the radiation oncologists were 3.70 and 3.53 for PU-MRI (k = 0.93), 3.67 and 2.70 for EDSR (k = 0.89), 3.70 and 2.73 for WDSR (k = 0.88), 3.67 and 2.73 for SRGAN (k = 0.88), and 4.37 and 3.73 for RDN (k = 0.93), respectively. The results suggest that SR images using RDN are similar to the original images, and the SR deep learning models subjectively improve the visibility of the prostatic urinary tract.


Assuntos
Aprendizado Profundo , Masculino , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Uretra , Processamento de Imagem Assistida por Computador/métodos
3.
Phys Imaging Radiat Oncol ; 20: 23-29, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34693040

RESUMO

BACKGROUND AND PURPOSE: Urethra-sparing radiation therapy for localized prostate cancer can reduce the risk of radiation-induced genitourinary toxicity by intentionally underdosing the periurethral transitional zone. We aimed to compare the clinical impact of a urethra-sparing intensity-modulated proton therapy (US-IMPT) plan with that of conventional clinical plans without urethral dose reduction. MATERIALS AND METHODS: This study included 13 patients who had undergone proton beam therapy. The prescribed dose was 63 GyE in 21 fractions for 99% of the clinical target volume. To compare the clinical impact of the US-IMPT plan with that of the conventional clinical plan, tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated with a generalized equivalent uniform dose-based Lyman-Kutcher model using dose volume histograms. The endpoints of these model parameters for the rectum, bladder, and urethra were fistula, contraction, and urethral stricture, respectively. RESULTS: The mean NTCP value for the urethra in US-IMPT was significantly lower than that in the conventional clinical plan (0.6% vs. 1.2%, p < 0.05). There were no statistically significant differences between the conventional and US-IMPT plans regarding the mean minimum dose for the urethra with a 3-mm margin, TCP value, and NTCP value for the rectum and bladder. Additionally, the target dose coverage of all plans in the robustness analysis was within the clinically acceptable range. CONCLUSIONS: Compared with the conventional clinically applied plans, US-IMPT plans have potential clinical advantages and may reduce the risk of genitourinary toxicities, while maintaining the same TCP and NTCP in the rectum and bladder.

4.
Phys Imaging Radiat Oncol ; 18: 1-4, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34258400

RESUMO

The urethra position may shift due to the presence/absence of the catheter. Our proposed post-urination-magnetic resonance imaging (PU-MRI) technique is possible to identify the urethra without catheter. We aimed to verify the inter-operator difference in contouring the urethra by PU-MRI. The mean values of the evaluation indices of dice similarity coefficient, mean slice-wise Hausdorff distance, and center coordinates were 0.93, 0.17 mm, and 0.36 mm for computed tomography, and 0.75, 0.44 mm, and 1.00 mm for PU-MRI. Therefore, PU-MRI might be useful for identifying the prostatic urinary tract without using a urethral catheter. Clinical trial registration: Hokkaido University Hospital for Clinical Research (018-0221).

5.
PLoS One ; 6(5): e19314, 2011 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-21559303

RESUMO

Knowledge of the basic reproductive physiology of snow leopards is required urgently in order to develop a suitable management conditions under captivity. In this study, the long-term monitoring of concentrations of three steroid hormones in fecal matter of three female snow leopards was performed using enzyme immunoassays: (1) estradiol-17ß, (2) progesterone and (3) cortisol metabolite. Two of the female animals were housed with a male during the winter breeding season, and copulated around the day the estradiol-17ß metabolite peaked subsequently becoming pregnant. The other female was treated in two different ways: (1) first housed with a male in all year round and then (2) in the winter season only. She did not mate with him on the first occasion, but did so latter around when estradiol-17ß metabolite peaked, and became pseudopregnant. During pregnancy, progesterone metabolite concentrations increased for 92 or 94 days, with this period being approximately twice as long as in the pseudopregnant case (31, 42, 49 and 53 days). The levels of cortisol metabolite in the pseudopregnant female (1.35 µg/g) were significantly higher than in the pregnant females (0.33 and 0.24 µg/g) (P<0.05). Similarly, during the breeding season, the levels of estradiol-17ß metabolite in the pseudopregnant female (2.18 µg/g) were significantly higher than those in the pregnant females (0.81 and 0.85 µg/g) (P<0.05). Unlike cortisol the average levels of estradiol-17ß during the breeding season were independent of reproductive success.The hormone levels may also be related to housing conditions and the resulting reproductive success in female leopards. The female housed with a male during the non-breeding season had high levels of cortisol metabolites and low levels of estradiol-17ß in the breeding season, and failed to become pregnant. This indicates that housing conditions in snow leopards may be an important factor for normal endocrine secretion and resulting breeding success.


Assuntos
Estradiol/metabolismo , Hidrocortisona/metabolismo , Esteroides/metabolismo , Animais , Fezes , Felidae , Feminino , Técnicas Imunoenzimáticas/métodos , Masculino , Gravidez , Prenhez , Pseudogravidez , Comportamento Sexual Animal , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...