Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Clin Med ; 13(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38673430

RESUMO

Objectives: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve the outcomes in patients with symptomatic, refractory atrial fibrillation (AF). In this setting, AVJA can be performed simultaneously with implantation or in a second procedure a few weeks after implantation. Comparison data on these two alternative strategies are lacking. Methods: A prospective, multicentre, observational study enrolled consecutive patients with symptomatic, refractory AF undergoing CSP and AVJA performed in a single procedure or in two separate procedures. Data on the long-term outcomes and healthcare resource utilization were prospectively collected. Results: A total of 147 patients were enrolled: for 105 patients, CSP implantation and AVJA were performed simultaneously (concomitant AVJA); in 42, AVJA was performed in a second procedure, with a mean of 28.8 ± 19.3 days from implantation (delayed AVJA). After a mean follow-up of 12 months, the rate of procedure-related complications was similar in both groups (3.8% vs. 2.4%; p = 0.666). Concomitant AVJA was associated with a lower number of procedure-related hospitalizations per patient (1.0 ± 0.1 vs. 2.0 ± 0.3; p < 0.001) and with a lower number of hospital treatment days per patient (4.7 ± 1.8 vs. 7.4 ± 1.9; p < 0.001). Conclusions: Concomitant AVJA resulted as being as safe as delayed AVJA and was associated with a lower utilization of healthcare resources.

2.
Heart Rhythm ; 21(6): 874-880, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38428448

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking. OBJECTIVE: The aim of this study was to compare the long-term risk of procedure-related complications between LBBAP and BVP in a cohort of patients undergoing CRT. METHODS: This prospective, multicenter, observational study enrolled 668 consecutive patients (mean age 71.2 ± 10.0 years; 52.2% male; 59.4% with New York Heart Association class III-IV heart failure symptoms) with left ventricular ejection fraction 33.4% ± 4.3% who underwent BVP (n = 561) or LBBAP (n = 107) for a class I or II indication for CRT. Propensity score matching for baseline characteristics yielded 93 matched pairs. The rate and nature of intraprocedural and long-term post-procedural complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up of 18 months, procedure-related complications were observed in 16 patients: 12 in BVP (12.9%) and 4 in LBBAP (4.3%) (P = .036). Compared with patients who underwent LBBAP, those who underwent BVP showed a lower complication-free survival (P = .032). In multivariate analysis, BVP resulted an independent predictive factor associated with a higher risk of complications (hazard ratio 3.234; P = .042). Complications related to the coronary sinus lead were most frequently observed in patients who underwent BVP (50.0% of all complications). CONCLUSION: LBBAP was associated with a lower long-term risk of device-related complications compared with BVP in patients with an indication for CRT.


Assuntos
Bloqueio de Ramo , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Pontuação de Propensão , Sistema de Registros , Volume Sistólico , Humanos , Masculino , Feminino , Idoso , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Estudos Prospectivos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Volume Sistólico/fisiologia , Resultado do Tratamento , Fascículo Atrioventricular/fisiopatologia , Seguimentos , Função Ventricular Esquerda/fisiologia
3.
Pacing Clin Electrophysiol ; 46(10): 1258-1268, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37665040

RESUMO

BACKGROUND: Conduction system pacing (CSP), including His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP), have been proposed as alternatives to biventricular pacing (BVP) in patients scheduled for ablate and pace (A&P) strategy. The aim of this study was to compare the clinical outcomes, including the rate and nature of device-related complications, between BVP and CSP in a cohort of patients undergoing A&P. METHODS: Prospective, multicenter, observational study, enrolling consecutive patients undergoing A&P. The risk of device-related complications and of heart failure (HF) hospitalization was prospectively assessed. RESULTS: A total of 373 patients (75.3 ± 8.7 years, 53.9% male, 68.9% with NYHA class ≥III) were enrolled: 263 with BVP, 68 with HBP, and 42 with LBBAP. Baseline characteristics of the three groups were similar. Compared to BVP and HBP, LBBAP was associated with the shortest mean procedural and fluoroscopy times and with the lowest acute capture thresholds (all p < .05). At 12-month follow-up LBBAP maintained the lowest capture thresholds and showed the longest estimated residual battery longevity (all p < .05). At 12-months follow-up the three study groups showed a similar risk of device-related complications (5.7%, 4.4%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .650), and of HF hospitalization (2.7%, 1.5%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .850). CONCLUSIONS: In the setting of A&P, CSP is a feasible pacing modality, with a midterm safety profile comparable to BVP. LBBAP offers the advantage of reducing procedural times and obtaining lower and stable capture thresholds, with a positive impact on the device longevity.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Estudos Prospectivos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fontes de Energia Elétrica , Insuficiência Cardíaca/terapia , Fascículo Atrioventricular , Resultado do Tratamento , Eletrocardiografia , Estimulação Cardíaca Artificial
4.
Heart Rhythm ; 20(7): 984-991, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36906165

RESUMO

BACKGROUND: Conduction system pacing (CSP) using His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has emerged as an alternative to right ventricular pacing (RVP). Comparative data on the risk of complications between CSP and RVP are lacking. OBJECTIVE: This prospective, multicenter, observational study aimed to compare the long-term risk of device-related complications between CSP and RVP. METHODS: A total of 1029 consecutive patients undergoing pacemaker implantation with CSP (including HBP and LBBAP) or RVP were enrolled. Propensity score matching for baseline characteristics yielded 201 matched pairs. The rate and nature of device-related complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up duration of 18 months, device-related complications were observed in 19 patients: 7 in RVP (3.5%) and 12 in CSP (6.0%) (P = .240). On dividing the matched cohort into 3 groups with similar baseline characteristics according to pacing modality (RVP, n = 201; HBP, n = 128; LBBAP, n = 73), patients with HBP showed a significantly higher rate of device-related complications than did patients with RVP (8.6% vs 3.5%; P = .047) and patients with LBBAP (8.6% vs 1.3%; P = .034). Patients with LBBAP showed a rate of device-related complications similar to that of patients with RVP (1.3% vs 3.5%; P = .358). Most of the complications observed in patients with HBP (63.6%) were lead related. CONCLUSION: Globally, CSP was associated with a risk of complications similar to that of RVP. Considering HBP and LBBAP separately, HBP showed a significantly higher risk of complications than did both RVP and LBBAP whereas LBBAP showed a risk of complications similar to that of RVP.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estudos Prospectivos , Pontuação de Propensão , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Doença do Sistema de Condução Cardíaco , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 33(11): 2288-2296, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35930617

RESUMO

INTRODUCTION: In patients with symptomatic permanent atrial fibrillation (PEAF) and narrow QRS, atrio-ventricular junction ablation (AVJA) plus cardiac resynchronization therapy (CRT) is superior to medical therapy in reducing heart failure (HF) hospitalization and all-cause mortality. To compare the mortality of a population of patients with HF, reduced EF (rEF), and PEAF treated with AVJA plus CRT with that of a contemporary cohort of patients in sinus rhythm (SR) with similar baseline characteristics. METHODS AND RESULTS: In this prospective, multicentre, observational study, all-cause mortality in a group of consecutive patients undergoing AVJA and implantable cardioverter-defibrillator (ICD) combined with CRT implantation for HFrEF, narrow QRS, and PEAF with uncontrolled ventricular rate was compared with that of a contemporary cohort of patients in SR undergoing ICD implantation (not combined with CRT) for HFrEF and narrow QRS. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 824 patients were enrolled. Propensity matching yielded 107 matched pairs. After a median follow-up of 52 months, all-cause mortality was similar in patients treated with AVJA plus CRT and in the control group (p = .434). In AVJA plus CRT patients, mortality was significantly lower than in control group patients with a history of paroxysmal/persistent AF (n = 45, p = .020), and similar to that of patients without a history of AF (n = 62, p = .459). CONCLUSIONS: After adjustment for patient characteristics, the long-term prognosis of patients with HFrEF, narrow QRS, and PEAF who underwent AVJA plus CRT was similar to that of a population of patients in SR with similar characteristics.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia
6.
Pacing Clin Electrophysiol ; 44(9): 1532-1539, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34374444

RESUMO

BACKGROUND: His bundle pacing (HBP), alone or optimized in association with coronary sinus pacing (HBP+LV) has recently been proposed as an alternative to conventional cardiac resynchronization therapy (CRT). However, there is lack of controlled studies that assessed clinical outcome. METHODS: We did a single-center, propensity-score matched, case-control study of comparison of HBP and HBP+LV versus conventional CRT in patients with heart failure (HF) and standard indications for CRT. The study group patients were consecutively enrolled in the year 2019. The control group patients were selected, by propensity score matching, among those CRT implantations performed in the years 2015-2018. RESULTS: There were 27 patients in each group. In the active group, 12 (44%) patients received HBP alone and 12 (44%) patients HBP+LV pacing. HBP failed in three (11%) patients. In the control group, conventional CRT was achieved in 26 (96%) patients and failed in one. Paced QRS width was shorter in the active than in the control group (128 ± 18 vs. 148 ± 27 ms, p = .004). During a mean of 9.6 months of follow-up, a composite clinical outcome of death, hospitalization for HF or worsening HF occurred in three (11%) in the active group and in four (15%) in the control group, p = .58. No difference was also observed with softer endpoints: NYHA class (1.9 ± 0.7 vs. 2.1 ± 0.7), subjective improvement (74% vs. 74%) and LV ejection fraction (40.7% vs. 40.7%). CONCLUSION: Compared with conventional CRT, a shorter QRS width can be obtained with HBP alone or in association with coronary sinus pacing but we were unable to show a better clinical outcome. There is urgent need for large, randomized trials.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pontuação de Propensão
7.
J Electrocardiol ; 68: 85-89, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34403948

RESUMO

PURPOSE: The implantation site of the His bundle (HB) lead may influence pacing parameters. Our aim was to characterize the anatomical location of the HB lead tip and its relationship with acute electrical parameters. METHODS: Consecutive patients who underwent HB lead implantation, guided by standard fluoroscopy and electrophysiology, were prospectively enrolled. The relationship between HB lead tip and tricuspid valve plane (TVP) was assessed with post-procedure transthoracic echocardiography. RESULTS: Twenty-five patients were studied. In 11 patients (44%), the HB lead tip did not cross the TVP (A group): in 7 cases it was screwed in the right atrium at a mean distance of -6.1 mm from the TVP and, in 4 cases, at the level of the tricuspid annulus. In the remaining 14 patients (56%), the lead tip crossed the TVP (V group): it was screwed in the right ventricle at a mean distance of 9.3 mm from the TVP. A and V groups had comparable HB capture thresholds (1.6 ± 1 V vs 1.7 ± 0.7 V, 1 ms pulse-width; p = 0.66); selective HB capture was significantly more represented in the A group (91% vs 21%; p = 0.001). Significantly higher R-wave amplitudes were seen in the V group (6.7 ± 3 vs 2.5 ± 1.7 mV; p = 0.0004), and they positively correlated with the distance from the TVP (p = 0.0038). Atrial oversensing was never observed. CONCLUSION: In a consecutive cohort of HB pacing recipients, the rate of patients who had an effective HB capture in the atrium was substantial and was characterized by different electrophysiological properties than in the ventricle.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Ecocardiografia , Eletrocardiografia , Frequência Cardíaca , Humanos
8.
J Electrocardiol ; 64: 95-98, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33412431

RESUMO

We present the case of a professional soccer player affected by right bundle branch block and symptomatic 2:1 atrio-ventricular block during effort, due to progressive cardiac conduction disease (Lev-Lenegre disease), who received successful left bundle branch area pacing after a failed attempt at His bundle pacing. The electrocardiographic outcome of paced QRS was consistent with a rapid electrical activation of the left ventricle through the Purkinje system. The pursue of physiological pacing was preferred over conventional, given the young age of our patient and the expectedly high burden of stimulation, to reduce the long-term risk of pacing-induced cardiomyopathy.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Atletas , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Humanos
9.
Am J Case Rep ; 19: 1146-1151, 2018 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-30262801

RESUMO

BACKGROUND Mitral valve aneurysms (MVAs) are uncommon conditions frequently associated with aortic valve endocarditis. They may be complicated by perforation and severe mitral regurgitation (MR). Optimal treatment of MVA, and in particular the best timing for surgery, are uncertain. CASE REPORT A 62-year-old man with a recent history of dental surgery presented to the Emergency Department complaining relapsing fever. A first echocardiogram demonstrated infective endocarditis of the aortic valve. The patient was primarily managed with specific antibiotic therapy. Despite this, a few days later he suffered from splenic embolization and an MVA with MR was detected. Surgical replacement of the mitral and aortic valves was therefore performed. CONCLUSIONS MVAs are infrequent but potentially severe complications of AV endocarditis. In the absence of definite treatment indication, the correct time for surgery should depend on concomitant clinical and infective features.


Assuntos
Valva Aórtica/cirurgia , Endocardite Bacteriana/cirurgia , Aneurisma Cardíaco/cirurgia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/tratamento farmacológico , Aneurisma Cardíaco/etiologia , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia
10.
J Pediatr Orthop B ; 26(1): 14-20, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27058817

RESUMO

The authors have developed a particular surgical technique (olecranon bone resection together with anterior elbow arthrolysis) to increase the elbow's range of motion in adolescents and young adults suffering from elbow flexion contracture in obstetrical palsy sequelae. The surgical procedure was carried out in a preliminary group of 11 patients. The original procedure included a double incision: first of all by means of a posterior approach to resect the tip of the olecranon and then another incision carried out through the anteromedial aspect of the elbow, with a view to performing the anterior capsulotomy. Preoperatively, the average clinical elbow extension was 64.9°, whereas after surgery, the value increased to 43.63°. The average DASH score was 38.27 points before surgery, whereas it decreased to 29.98 points after surgery. A statistical analysis was also carried out to confirm the outcome. The procedure is reliable, is not time-consuming, and does not lead to any major complications.


Assuntos
Neuropatias do Plexo Braquial/complicações , Plexo Braquial/cirurgia , Contratura/cirurgia , Articulação do Cotovelo/cirurgia , Cotovelo/cirurgia , Olécrano/cirurgia , Adolescente , Adulto , Braço/cirurgia , Artroplastia/métodos , Traumatismos do Nascimento/complicações , Seguimentos , Humanos , Procedimentos Ortopédicos , Amplitude de Movimento Articular , Adulto Jovem
12.
Indian J Orthop ; 49(5): 554-60, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26538763

RESUMO

BACKGROUND: Direct neurorrhaphy, nerve grafting interposition and neurotization are the options for nerve repair in children, whereas few reports about using nerve conduits (tubulization) are referred to pediatrics in the literature. The authors present their experience about nerve repairing by means of nerve tubes during the developmental age when the harvesting of nerve grafts and also vein grafts of adequate caliber for bridging nerve defects is difficult. A critical review of their case series offers indications for using nerve conduits in pediatrics. MATERIALS AND METHODS: Fifteen patients were treated using the nerve tubulization; nine patients were affected by obstetrical brachial plexus palsy (OBPP) while six were suffering from peripheral nerve injuries (PNIs). RESULTS: In patients suffering from OBPP, we observed 1 good, 3 fair and 5 bad results. In the PNI group, we observed 4 patients who had good results while only 2 had a bad outcome. No fair results were observed. CONCLUSIONS: In peripheral nerve repairing in children by using nerve conduits, the outcome has been widely effective even when dealing with mixed and motor nerve, thus nerve tubulization might be considered as an alternative to nerve grafting. Conversely, considering the uncertain result obtained in brachial plexus repairing, the conduits cannot be considered as a first choice of treatment in brachial plexus reconstruction.

13.
J Brachial Plex Peripher Nerve Inj ; 10(1): e2-e14, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27917233

RESUMO

OBJECTIVE: When root avulsions are detected in children suffering from obstetrical brachial plexus palsy (OBPP), neurotization procedures of different nerve trunks are commonly applied in primary brachial plexus repair, to connect distally the nerves of the upper limbs using healthy nerve structures. This article aims to outline our experience of neurotization procedures in OBPP, which involves nerve transfers in the event of delayed repair, when a primary repair has not occurred or has failed. In addition, we propose the opportunity for late repair, focusing on extending the time limit for nerve surgery beyond that which is usually recommended. Although, according to different authors, the time limit is still unclear, it is generally estimated that nerve repair should take place within the first months of life. In fact, microsurgical repair of OBPP is the technique of choice for young children with the condition who would otherwise have an unfavorable outcome. However, in certain cases the recovery process is not clearly defined so not all the patients are direct candidates for primary nerve surgery. METHODS: In the period spanning January 2005 through January 2011, among a group of 105 patients suffering from OBPP, ranging from 1 month to 7 years of age, the authors have identified a group of 32 partially recovered patients. All these patients underwent selective neurotization surgery, which was performed in a period ranging from 5 months to 6.6 years of age. RESULTS: Late neurotization of muscular groups achieved considerable functional recovery in these patients, who presented with reduced motor function during early childhood. The said patients, with the exception of five, would initially have avoided surgery because they had not met the criteria for nerve surgery. CONCLUSION: We have concluded that the execution of late nerve surgical procedures can be effective in children affected by OBPP.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...