Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Indian J Ophthalmol ; 70(12): 4168-4171, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36453307

RESUMO

Purpose: To evaluate the safety and efficacy of ultrasound cycloplasty in eyes with primary or secondary open-angle glaucoma, not amenable to adequate control of intra-ocular pressure (IOP) with medical treatment. Methods: Prospective interventional cohort study of 28 eyes of 28 subjects in a tertiary eye care centre in India in patients with open-angle glaucoma. All enrolled eyes underwent ultrasound cycloplasty with the second-generation probe with six shots of 8 s each, operated by a single surgeon between November 2018 and January 2020. They were followed up for a period of 12 months. The primary treatment outcome was IOP and the secondary outcomes were vision and postoperative complications. Results: A total of 28 eyes of 28 patients were studied, and the mean age was 63.82 ± 6.46 years. Primary open-angle glaucoma (75%) was the most common etiology. There was significant reduction in IOP from the baseline (24.93 ± 4.27 mmHg) to the postoperative value (15.82 ± 3.14 mmHg) at the end of 12 months (P < 0.00001). Mean reduction in IOP was 9.14 ± 4.09 mmHg at 12 months (36.66%). Number of ocular hypotensives reduced significantly from baseline (3.32 ± 0.47) to 12-month postoperative follow-up (0.68 ± 0.74) (P < 0.00001). Qualified success was achieved in 89.28% eyes. No major complications were noted. Conclusion: Ultrasound cycloplasty is found to be effective and safe in eyes with open-angle glaucoma because of the primary or secondary etiology, being more effective in the former.


Assuntos
Glaucoma de Ângulo Aberto , Humanos , Pessoa de Meia-Idade , Idoso , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Estudos de Coortes , Estudos Prospectivos , Olho , Tonometria Ocular
2.
Indian J Ophthalmol ; 68(2): 371-374, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31957731

RESUMO

Purpose: Glaucoma is the leading cause of irreversible blindness in the world. The current study aims to estimate prevalence, features, and associations of open angle glaucoma (OAG) in a rural and urban East Indian population. Methods: This is a population based cross sectional study with two arms, rural (28 contiguous villages from 13 Gram Panchayats in Balagarh Police Station, Hooghly district) and urban (Kolkata). Individuals residing in the study area aged 40 years and above were included using multistage random cluster sampling. All subjects underwent a detailed ophthalmic examination at our base hospitals including applanation tonometry, ultrasound pachymetry, gonioscopy, and frequency doubling technology perimetry. The primary outcome was the prevalence of POAG (95% CI). Age and gender specific prevalence estimates were calculated. Multiple logistic regressions were used to analyze the risk factors. Results: Data from 7128 and 6964 subjects aged 40 years or older from Kolkata city and Hooghly district, respectively were analyzed. In the urban population, 2.10% (95% CI: 1.99-2.21%) had POAG and 0.15% (95% CI: 0.13-0.17%) had secondary OAG. In the rural population, 1.45% (95% CI: 0.59-2.31%) had POAG and 0.10 ± 0.03% (95% CI: 0.07-0.13%) had secondary OAG. Conclusion: The study concludes that higher age, higher vertical cup disc ratio (VCDR), and lower central corneal thickness (CCT) are important independent predictors of OAG and emphasizes that increased intraocular pressure (IOP) is not POAG. Gonioscopy, disc evaluation, and screening perimetry need to be incorporated in the detection protocol for glaucoma if we intend to lighten the burden of blindness due to glaucoma.


Assuntos
Glaucoma de Ângulo Aberto/epidemiologia , Pressão Intraocular/fisiologia , Medição de Risco/métodos , População Rural , População Urbana , Campos Visuais/fisiologia , Adulto , Distribuição por Idade , Idoso , Estudos Transversais , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Gonioscopia , Humanos , Índia/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Distribuição por Sexo
3.
Indian J Ophthalmol ; 66(9): 1285-1290, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30127142

RESUMO

Purpose: To estimate the prevalence, features, and associations of primary angle closure disease (PACD) in rural and urban populations from West Bengal in eastern India. Methods: This was a population-based cross-sectional study with two arms, rural and urban. The rural study area consisted of 28 contiguous villages from 13 gram panchayats in Balagarh Police Station, with rural base hospital at Dhobapara, Balagarh Police Station, in the village Kuliapara of Hooghly district. A tertiary eye hospital in central Kolkata was the urban study center. Individuals residing in the study area aged 40 years and above were included in this study using multistage random cluster sampling. All subjects underwent a detailed ophthalmic examination at our base hospitals including applanation tonometry, ultrasound pachymetry, gonioscopy, and frequency doubling technology perimetry. Data collected were analyzed using SPSS 13. Multiple logistic regressions were used to analyze risk factors for PACD. Results: A total of 7,408 and 7,248 subjects aged 40 years or older were enumerated from Hooghly district and Kolkata city, respectively. PACD was detected in 1.9% subjects in rural arm and 1.54% subjects in the urban arm (P < 0.001). In rural arm, 0.3% had PACS, 0.56% had PAC, and 1.03% had PACG. In urban arm, 0.22% had PACS, 0.35% had PAC, and 0.97% had PACG. Conclusion: The study concludes that higher age, higher CCT, and shorter axial length/presence of hyperopia are important independent predictors of ACD. ACD is more common in eastern India than previous estimates.


Assuntos
Glaucoma de Ângulo Fechado/epidemiologia , Pressão Intraocular/fisiologia , População Rural , População Urbana , Campos Visuais , Distribuição por Idade , Paquimetria Corneana , Estudos Transversais , Feminino , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/fisiopatologia , Gonioscopia , Humanos , Índia/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Distribuição por Sexo
4.
Indian J Ophthalmol ; 64(8): 578-83, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27688279

RESUMO

CONTEXT: Glaucoma is the leading cause of global irreversible blindness. No recent study with adequate sample size has been carried out to estimate glaucoma prevalence in Eastern India. AIMS: The aim of this study was to assess and compare the prevalence and types of glaucoma in a rural and urban East Indian population. SETTINGS AND DESIGN: The Hooghly River Glaucoma Study (HRGS) is a population-based cross-sectional study from West Bengal. A tertiary hospital in Kolkata was our urban study center. Our rural study area included 28 contiguous villages from the district of Hooghly surrounding the rural base hospital located at Dhobapara in village Bakulia. Individuals aged 40 years and above were included in this study. SUBJECTS AND METHODS: All subjects underwent a detailed ophthalmic examination at our base hospitals including applanation tonometry, ultrasound pachymetry, gonioscopy, and frequency doubling technology perimetry. Glaucoma was defined using modified International Society of Geographical and Epidemiological Ophthalmology criteria. STATISTICAL ANALYSIS USED: Analysis was performed using Chi-square test and multiple logistic regression using SPSS. RESULTS: Totally, 14,092 individuals participated; 2.7% were detected to have glaucoma in rural arm and 3.23% in urban arm (P < 0.001). In urban population, 2.10% had primary open angle glaucoma (POAG), 0.97% had primary angle closure glaucoma (PACG), and 0.15% had secondary glaucoma. In rural population, 1.45% had POAG, 1.15% had ACG, and 0.10% had secondary glaucoma. CONCLUSIONS: HRGS is the largest population-based glaucoma study in India to date with glaucoma prevalence comparable to other landmark Indian studies. POAG was the most common form of glaucoma in our study population as well. PACG was more common in this region than previously thought.


Assuntos
Glaucoma de Ângulo Fechado/epidemiologia , Glaucoma de Ângulo Aberto/epidemiologia , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Glaucoma de Ângulo Fechado/classificação , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Aberto/classificação , Glaucoma de Ângulo Aberto/diagnóstico , Gonioscopia , Humanos , Índia/epidemiologia , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Rios , População Rural/estatística & dados numéricos , Distribuição por Sexo , População Urbana/estatística & dados numéricos , Campos Visuais
5.
Indian J Ophthalmol ; 60(3): 218-20, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22569386

RESUMO

Foldable intraocular lens (IOL) implantation using an injector system through 2.8-mm clear corneal incision following phacoemulsification provides excellent speedy postoperative recovery. In our reported case, a Sensar AR40e IOL (Abbott Medical Optics, USA) was loaded into Emerald C cartridge, outside the view of the operating microscope, by the first assistant. The surgeon proceeded with the IOL injection through a 2.8-mm clear corneal incision after uneventful phacoemulsification, immediately following which he noted a Descemet's tear with a rolled out flap of about 2 mm near the incision site. Gross downward beaking of the bevelled anterior end of the cartridge was subsequently noticed upon examination under the microscope. We suggest careful preoperative microscopic inspection of all instruments and devices entering the patient's eyes to ensure maximum safety to the patient.


Assuntos
Lâmina Limitante Posterior/lesões , Traumatismos Oculares/etiologia , Implante de Lente Intraocular/efeitos adversos , Cartilagem , Falha de Equipamento , Traumatismos Oculares/diagnóstico , Feminino , Humanos , Injeções/efeitos adversos , Injeções/instrumentação , Complicações Intraoperatórias , Implante de Lente Intraocular/instrumentação , Pessoa de Meia-Idade , Ruptura
6.
Micron ; 43(9): 937-47, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22522120

RESUMO

OBJECTIVE: Surface roughness parameters of various intraocular lenses (IOLs) biomaterials using atomic force microscopy (AFM) are compared. Variation, if any, in the micro-roughness properties of different IOLs made up of the same biomaterial is also explored. Retrospective analysis of posterior capsular opacification (PCO) incidence has been followed up for a period of four years post IOL implantation to evaluate the correlation of PCO formation with surface roughness of IOLs. DESIGN: Experimental materials study. MATERIALS AND PARTICIPANTS: Surface characteristics of 20 different IOL models were assessed using AFM. These IOL models were made up of PMMA or HEMA or acrylic hydrophobic or acrylic hydrophilic or silicone. Retrospective analysis of PCO incidence in 3629 eyes of 2656 patients implanted with the same IOL models was performed. METHODS: Topological characteristics of 20 different IOLs made up of 5 different biomaterials including (i) PMMA, (ii) HEMA, (iii) acrylic hydrophobic, (iv) acrylic hydrophilic and (v) silicone were evaluated using AFM in the tapping mode. Images were acquired with a resolution of 256 × 256 data points per scan at a scan rate of 0.5 Hz per line and a scan size of 10 × 10µm. Rate of PCO formation in 3629 eyes of 2656 patients implanted with the five different IOL biomaterials was retrospectively analyzed. RESULTS: AFM images of IOL optic surfaces showed a collection of pores, grooves, ridges and surface irregularities. Surface roughness parameters of the IOL optics were significantly different on comparing lenses of different materials. Acrylic hydrophobic IOLs had minimum surface roughness while acrylic hydrophilic IOLs showed the highest surface roughness. Different IOL models of the same biomaterial showed varied topological roughness characteristics. Retrospective analyses of PCO formation rate after IOL implantation was carried out, which revealed that rate of PCO incidence, was directly proportional to the increase in surface micro-roughness of IOLs. CONCLUSIONS: AFM is a powerful technique for the topological characterization of IOLs. Acrylic hydrophobic IOLs showed minimum surface roughness properties as well as minimum PCO incidence over a period of four years post implantation. It is, therefore, tempting to consider acrylic hydrophobic IOLs over other IOL biomaterials as the ideal biocompatible material for lowering PCO incidence. These results suggest an urgent need for manufacturers to optimize the various steps involved in the fabrication of IOLs.

7.
Indian J Ophthalmol ; 59(3): 191-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21586838

RESUMO

CONTEXT: Ranibizumab and bevacizumab are used widely for treating patients with choroidal neovascular membrane (CNVM) secondary to age-related macular degeneration (AMD). AIMS: To determine and compare the efficacy and safety of intravitreal ranibizumab and bevacizumab in treatment of CNVM due to AMD. SETTINGS AND DESIGN: Prospective comparative case series carried out in an eye institute and eye department of a hospital in Kolkata, India. MATERIALS AND METHODS: One hundred and four eyes with CNVM due to AMD were randomized into two groups. Group A (n=54; 24 occult) received monthly intravitreal ranibizumab injections (0.5 mg in 0.05 ml) and Group B (n=50; 22 occult) received monthly bevacizumab injections (1.25 mg in 0.05 ml) for 3 consecutive months and then as per study criteria. Data analysis done using SPSS software. P-value of <0.05 was considered statistically significant. RESULTS: The mean best corrected visual acuity (BCVA) in the ranibizumab group increased from 58.19 Early Treatment Diabetic Retinopathy Study (ETDRS) letters at baseline to 64 ETDRS letters at month 3 (P<0.001). In bevacizumab group mean BCVA increased from 56.80 to 61.72 ETDRS letters at month 3 (P<0.001). At the end of 18 months, there was no statistically significant difference between groups A and B with respect to change in BCVA (P=0.563) or central macular thickness (CMT; P=0.281), as measured by optical coherence tomography (Stratus OCT 3000). No significant sight-threatening complications developed. CONCLUSIONS: Ranibizumab and bevacizumab are equally safe and efficacious in treating CNVM due to AMD.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Anticorpos Monoclonais/administração & dosagem , Neovascularização de Coroide/tratamento farmacológico , Neovascularização de Coroide/etiologia , Degeneração Macular/complicações , Inibidores da Angiogênese/efeitos adversos , Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais Humanizados , Bevacizumab , Feminino , Humanos , Injeções Intravítreas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ranibizumab , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...