1.
Medicine (Baltimore) ; 101(35): e30121, 2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36107611

RESUMO

BACKGROUND: Activation of venous flow has been shown with different types of electrical stimulation. The aim of this study is to compare the hemodynamic effects of transcutaneous electrical nerve stimulation (TENS), neuromuscular electrical stimulation (NMES), and sham stimulation on healthy young people. METHODS: This randomized crossover study was conducted during June 2018 in the Faculty of Physical Therapy of A Coruña (Spain). Twenty-four university students (50% male) received in a randomized order 5 Hz-TENS, NMES, and sham stimulation on soleus muscle. Flow volume (FV) and peak velocity (PV) from popliteal vein were recorded via Doppler ultrasound, and relative changes from baseline were determined. Discomfort among the 3 stimulations was also compared. RESULTS: The differences among the 3 stimulations were assessed using the ANOVA for repeated measured, the Friedman test and the Kendall tau test, according to the type of measurement to be compared. FV (mL/min) and PV (cm/s) increased significantly after NMES (percentual increase 37.2 ± 62.0%, P = .002; 264.4 ± 152.2%, P < .001, respectively) and TENS (226.2 ± 190.3%, P < .001; 202.7 ± 144.6%, P < .001, respectively). These percentual changes from basal level in hemodynamics were statistically different to those after placebo, which was ineffective enhancing hemodynamics. The improvements in FV were statistically higher with TENS than with NMES (P < .001), but there was no statistical difference in PV (P = .531). Despite NMES was applied at a significantly lower amplitude than TENS (P < .001), NMES protocol was the worst tolerated, though the differences in discomfort were not statistically significant. CONCLUSION: Both active electrical protocols but not sham stimulation increased hemodynamics in healthy people. TENS obtained higher flow volume increase from baseline than NMES, considered globally at not only in its on-time.


Assuntos
Estimulação Elétrica Nervosa Transcutânea , Adolescente , Estudos Cross-Over , Estimulação Elétrica/métodos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Músculo Esquelético/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos
2.
Medicina (Kaunas) ; 56(2)2020 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-32085506

RESUMO

BACKGROUND AND OBJECTIVES: Palpation is an inherent and basic skill of health professionals-particularly manual therapists who base their diagnosis and treatment in a clinical environment. Many authors have previously described multiple palpation positions for supraspinatus muscle tendon (SMT); however, there are no current studies that evaluate palpation concordance reliability for the SMT in this particular position. This study aimed to investigate the intra- and inter-rater reliabilities of supraspinatus muscle tendon (SMT) palpation. MATERIALS AND METHODS: Thirty-six healthy participants (14 females; aged 22-35 years) were recruited. Musculoskeletal ultrasound was used to measure the SMT localization after two physiotherapists performed the SMT palpation at two different times. The distance between the two marked points was used to analyze the analysis of true agreement between examiners. Finally, we analyzed if the demographic variables influenced the palpation procedure. RESULTS: The intra-examiner reliability showed a high percentage of concordance for examiner 1 (E.1) (first palpation procedure (P.1) = 91.7%: second palpation procedure (P.2) = 95.8%) and examiner 2 (E.2) (P.1 = 91.6%; P.2 = 97.2%) and high percentage of inter-palpation agreement for E.1 (87.5%) and E.2 (88.9%). The inter-examiner reliability showed a high total concordance for the right shoulder (E.1 = 94.4%; E.2 = 95.8%) and left shoulder (E.1 = 93.05%; E.2 = 95.05%). The agreement (%) according to both examiners was 93.05% for the right shoulder and 94.4% for the left shoulder. The agreement between both examiners and the ultrasound (% of true agreement) was 92.9% for the right shoulder and 92.8% for the left shoulder. A statistically significant association (p = 0.02) was found for weight regarding concordance reliability; this was not seen for dominant arm, age, gender, body mass index, height, and tendon depth (p > 0.05). CONCLUSIONS: The SMT palpation technique showed a high level of concordance and reproducibility.


Assuntos
Variações Dependentes do Observador , Palpação/normas , Manguito Rotador/diagnóstico por imagem , Ultrassonografia/normas , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Palpação/métodos , Palpação/estatística & dados numéricos , Fisioterapeutas/normas , Fisioterapeutas/estatística & dados numéricos , Reprodutibilidade dos Testes , Manguito Rotador/fisiologia , Ultrassonografia/métodos , Ultrassonografia/estatística & dados numéricos
3.
Medicine (Baltimore) ; 97(36): e12084, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30200088

RESUMO

BACKGROUND: Transcutaneous electrical nerve stimulation (TENS) is used to prevent venous stasis and thromboembolism. However, best electrostimulation parameters have yet to be established. The aim of the study was to compare the hemodynamic effects and the participants' relative discomfort of 3 TENS sequences at the maximum tolerated intensity stimulus. METHODS: Twenty-four healthy university students (50% male) participated in a cross-over, randomized study. Each participant received 2 TENS sequences on peroneal nerve at 1 and 5 Hz, and the third one on soleus muscle at 5 Hz. Popliteal flow volume (FV) and peak velocity (PV) were measured using Doppler ultrasound and the relative change from basal values was recorded. Discomfort questionnaires -visual analogue scale (VAS) and verbal rating scale (VRS)- were also administered to compare sensations among the three applications. RESULTS: All interventions produced significant hemodynamic responses compared to baseline. Both 5 Hz applications obtained higher FV increments than 1 Hz TENS (P < .001). The muscle application resulted in the lowest PV increment (P < .001). TENS at 5 Hz on nerve location was the worst tolerated, with higher values in VRS (P = .056) and VAS (P = .11), although not significant. CONCLUSION: TENS at 5 Hz on soleus site may be the most appropriate protocol for enhancing venous return.


Assuntos
Hemodinâmica , Estimulação Elétrica Nervosa Transcutânea/métodos , Veias , Estudos Cross-Over , Feminino , Humanos , Masculino , Músculo Esquelético , Nervo Fibular , Estimulação Elétrica Nervosa Transcutânea/efeitos adversos , Ultrassonografia Doppler , Veias/diagnóstico por imagem , Veias/fisiologia , Adulto Jovem