Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dis Esophagus ; 30(8): 1-6, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28575248

RESUMO

Catheter probe endoscopic ultrasonography (C-EUS) by ultrasonographic jelly-filled method has been used to evaluate esophageal subepithelial tumors (SETs). Ultrasonographic jelly is safe on the skin, but its internal safety has not been demonstrated. The jelly stored at room temperature is easily injected into the esophagus through the instrument channel of the endoscope. However, using jelly stored at room temperature remains problematic because the jelly is drained rapidly. We used cold lubricating jelly and an intravenous extension tube to resolve these problems. In this study, we evaluated the safety and efficacy of cold lubricating jelly-filled method. The medical records of patients who underwent C-EUS by using water or cold lubricating jelly-filled method for esophageal SETs from March 2013 to September 2016 in Gangneung Asan hospital were reviewed. Clinical characteristics and EUS findings were evaluated retrospectively. Image quality and procedure time between water and cold lubricating jelly-filled method were compared retrospectively. This study included 138 patients (74 males, 64 females) with esophageal SET with a mean age of 57.1 ± 11.1 years. Thirty-four patients had lesions in the upper esophagus, 58 patients had lesions in the middle esophagus, and 46 patients had lesions in the lower esophagus. The EUS diagnoses were leiomyoma (82.6%), hemangioma (4.3%), extrinsic compressive lesion (3.6%), granulosa cell tumor (2.9%), ectopic calcification (1.4%), cyst (1.4%), lipoma (0.7%), varix (0.7%), and inconclusive lesion (2.2%). The mean image score in the cold lubricating jelly filled-method group was higher than that in the water-filled method group (3.2 ± 0.7 vs. 2.8 ± 0.7, P = 0.002). The procedure time in the cold lubricating jelly filled-method group was shorter than that in the water-filled method group (10 minutes 27 seconds ± 4 minutes 22 seconds versus 13 minutes 20 seconds ± 6 minutes 20 seconds, P = 0.045). No procedure-related complication was observed. C-EUS using the cold lubricating jelly-filled method seems to provide better image quality and shorter procedure time compared with C-EUS using the water-filled method.


Assuntos
Catéteres , Endossonografia/instrumentação , Neoplasias Esofágicas/diagnóstico por imagem , Lubrificantes/uso terapêutico , Idoso , Temperatura Baixa , Endossonografia/métodos , Mucosa Esofágica/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
2.
Clin Radiol ; 69(2): e78-85, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24290779

RESUMO

AIM: To investigate the value of diffusion-weighted imaging (DWI) for differentiating benign from malignant gallbladder lesions. MATERIALS AND METHODS: One hundred and twenty-six patients who had undergone magnetic resonance imaging (MRI) with DWI, in whom the histopathological diagnosis of their gallbladder lesions was confirmed by biopsy or surgery were retrospectively analysed. Thirty-six malignant and 90 benign lesions were included. Two radiologists categorized gallbladder lesions into seven types on two imaging sets [T2-weighted imaging (WI) alone and combined T2WI and DWI (b = 800 s/mm(2))] according to the presence of wall thickening, layered patterns, morphology of the mass, and diffusion restriction. Disagreements were resolved in consensus. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of each imaging set for diagnosing gallbladder carcinoma were calculated. The diagnostic performance of each imaging set was calculated using receiver operating characteristic (ROC) curve analysis. Additionally, ADC values of malignant and benign gallbladder lesions were compared separately for 1.5 and 3 T MRI. RESULTS: The sensitivity, specificity, PPV, and NPV of diagnosis at T2WI were 97.2%, 86.7%, 74.5%, and 98.7%, respectively. The sensitivity, specificity, PPV, and NPV using combined T2WI and DWI were 97.2%, 92.2%, 83.3%, and 98.8%, respectively. Diagnostic accuracy for gallbladder carcinoma slightly improved after adding DWI, from 0.92 to 0.95 (p < 0.05). ADC values for gallbladder carcinoma were significantly lower than those for benign lesions. Mean ADC values of malignant and benign lesions were 0.97 ± 0.25 × 10(-3) and 1.72 ± 0.56 × 10(-3) mm(2)/s, respectively, at 1.5 T (p < 0.001), and 1.04 ± 0.38 × 10(-3) and 2.2 ± 0.72 × 10(-3) mm(2)/s, respectively, at 3 T (p < 0.001). CONCLUSION: DWI can improve diagnostic accuracy for differentiating benign from malignant gallbladder lesions.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Vesícula Biliar/diagnóstico , Vesícula Biliar/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Diagnóstico Diferencial , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
3.
Cancer Res Treat ; 33(4): 296-301, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26680799

RESUMO

PURPOSE: Increased technologic capabilities have allowed for the expanded use of ultrasound beyond simple differentiation of a lesion as solid versus cystic nature, allowing us to classify lesions into various categories based on a number of descriptive features. The purpose of this study was to investigate whether to predict the preoperative prognosis of breast cancer through the correlation between ultrasonographic images and the grade of malignancy. MATERIALS AND METHODS: The patient population for this study consisted of 107 patients with infiltrative ductal carcinoma who were evaluated using ultrasound technology. Ultrasonographic findings were divided as follows: Type I, round or oval shape and regular border; Type II, partially round or oval shape and partially irregular border; and Type III, irregular shape and irregular border. RESULTS: 1. The frequency of grade 1 (G1) was significantly higher in the Type I group than the othergroups. 2. In the 2.0 cm sized mass, the lymph node metastasis rate was significantly lower in the Type I group than the other groups. 3. In all the groups, Estrogen receptor (ER) positivity was insignificant regardless of tumor size and type. 4. In the 2.0 cm sized mass, c-erbB-2 positivity was significantly lower in the Type I than the other groups. There was no clear difference among the three groups in tumors greater than 2.0 cm in size. CONCLUSION: These results show that our classification of ultrasonographic images reflect the grade of malignancy in terms of clinicopathological features in breast cancers less than 2.0 cm in size. Therefore, ultrasonographic findings may help predict the preoperative prognosis in T1 size breast cancer, although further study is required.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...