1.
Strahlenther Onkol ; 192(7): 473-80, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27221313

RESUMO

PURPOSE: Hippocampal-sparing whole brain radiotherapy (HS-WBRT) aims to preserve neurocognitive functions in patients undergoing brain radiotherapy (RT). Volumetric modulated arc therapy (VMAT) involves intensity-modulated RT using a coplanar arc. An inclined head position might improve dose distribution during HS-WBRT using VMAT. MATERIALS AND METHODS: This study analyzed 8 patients receiving brain RT with inclined head positioning. A comparable set of CT images simulating a non-inclined head position was obtained by rotating the original CT set. HS-WBRT plans of coplanar VMAT for each CT set were generated with a prescribed dose of 30 Gy in 10 fractions. Maximum dose to the hippocampi was limited to 16 Gy; to the optic nerve, optic chiasm, and eyeballs this was confined to less than 37.5 Gy; for the lenses to 8 Gy. Dosimetric parameters of the two different plans of 8 patients were compared with paired t-test. RESULTS: Mean inclined head angle was 11.09 ± 0.73°. The homogeneity (HI) and conformity (CI) indexes demonstrated improved results, with an average 8.4 ± 10.0 % (p = 0.041) and 5.3 ± 3.9 % (p = 0.005) reduction, respectively, in the inclined vs. non-inclined position. The inclined head position had lower hippocampi Dmin (10.45 ± 0.36 Gy), Dmax (13.70 ± 0.25 Gy), and Dmean (12.01 ± 0.38 Gy) values vs. the non-inclined head position (Dmin = 12.07 ± 1.07 Gy; Dmax = 15.70 ± 1.25 Gy; Dmean = 13.91 ± 1.01 Gy), with 12.8 ± 8.9 % (p = 0.007), 12.2 ± 6.8 % (p = 0.003), and 13.2 ± 7.2 % (p = 0.002) reductions, respectively. Mean Dmax for the lenses was 6.34 ± 0.72 Gy and 7.60 ± 0.46 Gy, respectively, with a 16.3 ± 10.8 % reduction in the inclined position (p = 0.004). Dmax for the optic nerve and Dmean for the eyeballs also decreased by 7.0 ± 5.9 % (p = 0.015) and 8.4 ± 7.2 % (p = 0.015), respectively. CONCLUSION: Inclining the head position to approximately 11° during HS-WBRT using VMAT improved dose distribution in the planning target volume and allowed lower doses to the hippocampi and optic apparatus.


Assuntos
Neoplasias Encefálicas/radioterapia , Irradiação Craniana/métodos , Traumatismos Oculares/prevenção & controle , Hipocampo/efeitos da radiação , Tratamentos com Preservação do Órgão/métodos , Posicionamento do Paciente/métodos , Lesões por Radiação/prevenção & controle , Adulto , Idoso , Neoplasias Encefálicas/complicações , Neoplasias Encefálicas/diagnóstico , Irradiação Craniana/efeitos adversos , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/etiologia , Feminino , Cabeça/efeitos da radiação , Humanos , Masculino , Pessoa de Meia-Idade , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Lesões por Radiação/diagnóstico , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...