Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Omega ; 9(11): 12689-12697, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38524422

RESUMO

Biomatrix-based reference materials (RMs) improve the quality of laboratory test results by better representing actual samples. However, a matrix RM of ephedrine (EP) for threshold substances that require accurate analysis results has not yet been developed. Therefore, this study aimed to develop an in-house matrix RM for EP and subsequently apply it to analytical procedures. During the development of the in-house matrix EP RM, the system underwent homogeneity and stability studies. Additionally, it was subjected to interlaboratory comparison study in 11 laboratories, including 10 World Anti-Doping Agency (WADA)-accredited laboratories and our laboratory. Stability testing revealed no significant changes in the RM characteristics. For homogeneity, 10 random batches out of 200 were analyzed to confirm the uniformity within and between bottles. These results, combined with data from 11 laboratories, ensured retroactive validation. The traceability value of the in-house matrix EP RM was assigned as 9.83 ± 0.57 µg/mL (k = 2) by interlaboratory comparison studies and traceable uncertain evaluation. The feasibility of this method as a single calibration standard was confirmed in two laboratories. This substance is reliable and consistent for quality control during EP quantification, ensuring accurate and trustworthy outcomes. Consequently, this study establishes a framework and guidelines for producing in-house matrix RMs and serves as a reference for generating similar matrix RMs in other contexts.

2.
PLoS One ; 18(12): e0295065, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38051722

RESUMO

As the number of prohibited drugs has been progressively increasing and analytical methods for detecting such substances are renewed continuously for doping control, the need for more sensitive and accurate doping analysis has increased. To address the urgent need for high throughput and accurate analysis, liquid chromatography with tandem mass spectrometry is actively utilized in case of most of the newly designated prohibited substances. However, because all mass spectrometer vendors provide data processing software that is incapable of handling other instrumental data, it is difficult to cover all doping analysis procedures, from method development to result reporting, on one platform. Skyline is an open-source and vendor-neutral software program invented for the method development and data processing of targeted proteomics. Recently, the utilization of Skyline has been expanding for the quantitative analysis of small molecules and lipids. Herein, we demonstrated Skyline as a simple platform for unifying overall doping control, including the optimization of analytical methods, monitoring of data quality, discovery of suspected doping samples, and validation of analytical methods for detecting newly prohibited substances. For method optimization, we selected the optimal collision energies for 339 prohibited substances. Notably, 195 substances exhibited a signal intensity increase of >110% compared with the signal intensity of the original collision energy. All data related to method validation and quantitative analysis were efficiently visualized, extracted, or calculated using Skyline. Moreover, a comparison of the time consumed and the number of suspicious samples screened in the initial test procedure highlighted the advantages of using Skyline over the commercially available software TraceFinder in doping control.


Assuntos
Dopagem Esportivo , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Software , Proteômica/métodos , Dopagem Esportivo/prevenção & controle
3.
Toxics ; 11(9)2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37755804

RESUMO

Di-(2-Ethylhexyl) phthalate (DEHP) is a prevalent environmental endocrine disruptor that affects homeostasis, reproduction, and developmental processes. The effects of DEHP have been shown to differ based on sex and sexual maturity. This study examines the metabolic profiles of mature adult rats from both sexes, aged 10 weeks, and adolescent female rats, aged 6 weeks, following a single 5 mg/kg of body weight DEHP oral administration. An untargeted metabolomic analysis was conducted on urine samples collected at multiple times to discern potential sex- and maturity-specific DEHP toxicities. Various multivariate statistical analyses were employed to identify the relevant metabolites. The findings revealed disruptions to the steroid hormone and primary bile acid biosynthesis. Notably, DEHP exposure increased hyocholic, muricholic, and ketodeoxycholic acids in male rats. Moreover, DEHP exposure was linked to heart, liver, and kidney damage, as indicated by increased plasma GOT1 levels when compared to the levels before DEHP exposure. This study provides detailed insights into the unique mechanisms triggered by DEHP exposure concerning sex and sexual maturity, emphasizing significant distinctions in lipid metabolic profiles across the different groups. This study results deepens our understanding of the health risks linked to DEHP, informing future risk assessments and policy decisions.

4.
Sci Rep ; 13(1): 3860, 2023 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-36890204

RESUMO

Erythropoietin (EPO) is a glycoprotein hormone that stimulates red blood cell production. It is produced naturally in the body and is used to treat patients with anemia. Recombinant EPO (rEPO) is used illicitly in sports to improve performance by increasing the blood's capacity to carry oxygen. The World Anti-Doping Agency has therefore prohibited the use of rEPO. In this study, we developed a bottom-up mass spectrometric method for profiling the site-specific N-glycosylation of rEPO. We revealed that intact glycopeptides have a site-specific tetra-sialic glycan structure. Using this structure as an exogenous marker, we developed a method for use in doping studies. The profiling of rEPO N-glycopeptides revealed the presence of tri- and tetra-sialylated N-glycopeptides. By selecting a peptide with a tetra-sialic acid structure as the target, its limit of detection (LOD) was estimated to be < 500 pg/mL. Furthermore, we confirmed the detection of the target rEPO glycopeptide using three other rEPO products. We additionally validated the linearity, carryover, selectivity, matrix effect, LOD, and intraday precision of this method. To the best of our knowledge, this is the first report of a doping analysis using liquid chromatography/mass spectrometry-based detection of the rEPO glycopeptide with a tetra-sialic acid structure in human urine samples.


Assuntos
Eritropoetina , Glicopeptídeos , Humanos , Glicopeptídeos/química , Ácido N-Acetilneuramínico , Eritropoetina/química , Proteínas Recombinantes , Espectrometria de Massas
5.
Drug Test Anal ; 13(2): 451-459, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33043621

RESUMO

Human insulin-like growth factor 1 (IGF-I) is the primary mediator of the effects of the growth hormone (GH). Therefore, it has been used as a biomarker to detect the abuse of GH in sports. The measurement of IGF-I relies on mass-based and immunological approaches to analysis. Among the mass-based analysis methods, liquid chromatography-mass spectrometry (LC-MS) has a number of functional advantages. LC-MS measurements based on the quantification of IGF-I, according to trypsin digestion, are used in the most common method of analyzing doping. However, this method is time-consuming and subject to experimental variability. In this study, we optimized a rapid method for detecting IGF-I without the trypsin digestion step. This method of analysis uses an ultra-centrifugal filter and an LC-HRMS through narrow-range mass scan method. To verify the validity of this method, eight categories of validation testing were applied with the following results: linearity, R2 > 0.99; limit of detection, 15 ng/ml; limit of quantification, 20 ng/ml; accuracy, >99%; recovery rate, >95%; carryover, <0.03; and inter- and intra-day precision values, %CV < 2% and %CV < 6%, respectively. Furthermore, we discussed the correlation of the quantified concentration from two other methods, immunoradiometric assay (IRMA) and parallel reaction monitoring method, using 209 serum samples. In conclusion, although both mass spectrometry-based methods worked equally well in terms of analytical performance and correlation with IRMA results, narrow-range mass scan method had several advantages, such as time and cost savings and reliable reproducibility, over the existing methods.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Fator de Crescimento Insulin-Like I/análise , Espectrometria de Massas/métodos , Dopagem Esportivo , Humanos , Limite de Detecção , Detecção do Abuso de Substâncias/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...