Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 16(15)2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37570175

RESUMO

This study investigates the use of eddy-current technology and impedance spectroscopy in sensing the change in rubber properties after it is exposed to accelerated thermal aging. The thermal aging process, by application of temperature and pressure over time, of ethylene propylene diene monomer (EPDM) rubbers containing both carbon black (CB) and graphene are investigated. Both eddy-current sensing and electrical impedance measurement techniques were used for electromagnetic analysis. Both methods measure the in- and out-of-phase responses as a function of excitation frequency at room temperature. The measurements were performed before and after the aging process. The electrical percolation threshold was detected in the rubber samples by varying the CB content from 0 to 40 wt%. In the rubber sample containing 30 wt% CB, 0-5 wt% of the CB was replaced with graphene flakes. The substitution of graphene for CB in the EPDM rubber formulation provided an enhanced eddy-current and electrical impedance response. The findings demonstrate the feasibility of employing electromagnetic analysis techniques to investigate the extent of aging.

2.
Nanomaterials (Basel) ; 13(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36615976

RESUMO

We have developed a nano-rheological characterization tool to extract the frequency- and scale-dependent rheological properties of soft materials during oral processing. Taking advantage of AC susceptometry, the dynamic magnetization of magnetic nanoparticles blended in the matrix material is measured. The magnetic AC susceptibility spectra of the particles are affected by the viscosity and mechanical modulus of the matrix material and provide the rheological properties of the matrix. Commercially available iron-oxide magnetic nanoparticles with 80 and 100 nm particle sizes are used as tracers in the frequency range of 1 Hz-10 kHz. The AC susceptibility is measured using two differentially connected coils, and the effects of the sample temperature and distance with respect to the detection coils are investigated. The developed measurement setup shows the feasibility of remote nano-rheological measurements up to 2 cm from the coil system, which can be used to, e.g., monitor the texture of matrix materials during oral processing.

3.
Biosensors (Basel) ; 9(3)2019 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-31533330

RESUMO

The specific binding of oligonucleotide-tagged 100 nm magnetic nanoparticles (MNPs) to rolling circle products (RCPs) is investigated using our newly developed differential homogenous magnetic assay (DHMA). The DHMA measures ac magnetic susceptibility from a test and a control samples simultaneously and eliminates magnetic background signal. Therefore, the DHMA can reveal details of binding kinetics of magnetic nanoparticles at very low concentrations of RCPs. From the analysis of the imaginary part of the DHMA signal, we find that smaller MNPs in the particle ensemble bind first to the RCPs. When the RCP concentration increases, we observe the formation of agglomerates, which leads to lower number of MNPs per RCP at higher concentrations of RCPs. The results thus indicate that a full frequency range of ac susceptibility observation is necessary to detect low concentrations of target RCPs and a long amplification time is not required as it does not significantly increase the number of MNPs per RCP. The findings are critical for understanding the underlying microscopic binding process for improving the assay performance. They furthermore suggest DHMA is a powerful technique for dynamically characterizing the binding interactions between MNPs and biomolecules in fluid volumes.


Assuntos
Técnicas Biossensoriais/métodos , Nanopartículas de Magnetita/química
4.
ACS Sens ; 4(9): 2381-2388, 2019 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-31397152

RESUMO

Assays are widely used for detection of various targets, including pathogens, drugs, and toxins. Homogeneous assays are promising for the realization of point-of-care diagnostics as they do not require separation, immobilization, or washing steps. For low concentrations of target molecules, the speed and sensitivity of homogeneous assays have hitherto been limited by slow binding kinetics, time-consuming amplification steps, and the presence of a high background signal. Here, we present a homogeneous differential magnetic assay that utilizes a differential magnetic readout that eliminates previous limitations of homogeneous assays. The assay uses a gradiometer sensor configuration combined with precise microfluidic sample handling. This enables simultaneous differential measurement of a positive test sample containing a synthesized Vibrio cholerae target and a negative control sample, which reduces the background signal and increases the readout speed. Very low concentrations of targets down to femtomolar levels are thus detectable without any additional amplification of the number of targets. Our homogeneous differential magnetic assay method opens new possibilities for rapid and highly sensitive diagnostics at the point of care.


Assuntos
Bioensaio/instrumentação , Fenômenos Magnéticos , DNA Bacteriano/análise , DNA Bacteriano/genética , Dispositivos Lab-On-A-Chip , Limite de Detecção , Técnicas de Amplificação de Ácido Nucleico , Vibrio cholerae/genética , Vibrio cholerae/isolamento & purificação
5.
Nanomaterials (Basel) ; 8(11)2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30388776

RESUMO

We developed a novel biodetection method for influenza virus based on AC magnetic susceptibility measurement techniques (the DynoMag induction technique) together with functionalized multi-core magnetic nanoparticles. The sample consisting of an incubated mixture of magnetic nanoparticles and rolling circle amplified DNA coils is injected into a tube by a peristaltic pump. The sample is moved as a plug to the two well-balanced detection coils and the dynamic magnetic moment in each position is read over a range of excitation frequencies. The time for making a complete frequency sweep over the relaxation peak is about 5 minutes (10 Hz⁻10 kHz with 20 data points). The obtained standard deviation of the magnetic signal at the relaxation frequency (around 100 Hz) is equal to about 10-5 (volume susceptibility SI units), which is in the same range obtained with the DynoMag system. The limit of detection with this method is found to be in the range of 1 pM.

6.
APL Bioeng ; 2(1): 016102, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31069287

RESUMO

A bioassay based on a high-Tc superconducting quantum interference device (SQUID) reading out functionalized magnetic nanoparticles (fMNPs) in a prototype microfluidic platform is presented. The target molecule recognition is based on volume amplification using padlock-probe-ligation followed by rolling circle amplification (RCA). The MNPs are functionalized with single-stranded oligonucleotides, which give a specific binding of the MNPs to the large RCA coil product, resulting in a large change in the amplitude of the imaginary part of the ac magnetic susceptibility. The RCA products from amplification of synthetic Vibrio cholera target DNA were investigated using our SQUID ac susceptibility system in microfluidic channel with an equivalent sample volume of 3 µl. From extrapolation of the linear dependence of the SQUID signal versus concentration of the RCA coils, it is found that the projected limit of detection for our system is about 1.0 × 105 RCA coils (0.2 × 10-18 mol), which is equivalent to 66 fM in the 3 µl sample volume. This ultra-high magnetic sensitivity and integration with microfluidic sample handling are critical steps towards magnetic bioassays for rapid detection of DNA and RNA targets at the point of care.

7.
Nanotechnology ; 25(42): 425201, 2014 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-25264978

RESUMO

Temperature dependent electronic properties of GaSb/InAsSb core/shell and GaSb nanowires have been studied. Results from two-probe and four-probe measurements are compared to distinguish between extrinsic (contact-related) and intrinsic (nanowire) properties. It is found that a thin (2-3 nm) InAsSb shell allows low barrier charge carrier injection to the GaSb core, and that the presence of the shell also improves intrinsic nanowire mobility and conductance in comparison to bare GaSb nanowires. Maximum intrinsic field effect mobilities of 200 and 42 cm(2) Vs(-1) were extracted for the GaSb/InAsSb core/shell and bare-GaSb NWs at room temperature, respectively. The temperature-dependence of the mobility suggests that ionized impurity scattering is the dominant scattering mechanism in bare GaSb while phonon scattering dominates in core/shell nanowires. Top-gated field effect transistors were fabricated based on radial GaSb/InAsSb heterostructure nanowires with shell thicknesses in the range 5-7 nm. The fabricated devices exhibited ambipolar conduction, where the output current was studied as a function of AC gate voltage and frequency. Frequency doubling was experimentally demonstrated up to 20 kHz. The maximum operating frequency was limited by parasitic capacitance associated with the measurement chip geometry.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...