Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Geriatr Cardiol ; 19(9): 675-684, 2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36284683

RESUMO

Background: Percutaneous left atrial appendage occlusion (LAAO) requires puncture of the interatrial septum. The immediate hemodynamic effects of iatrogenic atrial septal defects (iASD) after LAAO have not been examined so far. We aimed at evaluating these effects through invasive measurements of pressure and oxygen saturation. Moreover, we assessed the incidence of persistent iASD at three months. METHODS: Forty-eight patients scheduled for percutaneous LAAO were prospectively included in the study. Pressure and oxygen saturation were measured (1) in the right atrium (RA) before transseptal puncture, (2) in the left atrium (LA) through the transseptal sheath after transseptal puncture, (3) in the LA after removal of introducer sheath, and (4) in the RA after removal of introducer sheath. Transesophageal echocardiography was performed at three months to detect iASD. RESULTS: Pressure in the RA increased significantly after removing the introducer sheath (P = 0.034), whereas no difference was found in oxygen saturation in the RA (P = 0.623). Pressure measurement in the LA showed no significant difference after removing the introducer sheath (P = 0.718). Oxygen saturation in the LA also showed no significant difference (P = 0.129). Follow-up transesophageal echocardiogram at 3 months revealed a persistent iASD in 4 patients (8.5 %). CONCLUSIONS: Our study suggests that iASD after percutaneous LAAO does not result in significant shunts directly after the procedure, although a significant increase of mean right atrial pressure can be observed. Persistent iASDs after percutaneous LAAO seem to be relatively rare at three months.

2.
BMC Cardiovasc Disord ; 22(1): 349, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35918658

RESUMO

BACKGROUND: Percutaneous left atrial appendage occlusion (LAAO) represents an alternative stroke prevention method in patients with atrial fibrillation and an increased bleeding risk, chronic kidney disease or contraindications to oral anticoagulants. Aim of our study was to evaluate the feasibility and safety of percutaneous LAAO in high-risk, frail patients having undergone transcatheter aortic valve implantation (TAVI). METHODS: Thirty-one patients having undergone TAVI and scheduled for LAAO were prospectively included in our study. RESULTS: Implantation was successful in 29 of 31 cases (93.5%).There were no patients that developed a major acute cardiovascular event, stroke, or device dislocation/embolization. There was a single case of major bleeding (3.2%) and 3 cases of acute kidney injury (9.7%). At 3 months, no patients experienced a stroke, one patient had a device-related thrombus (3.4%), one patient showed a significant peri-device leak, and one patient had a persistent iatrogenic atrial septal defect. CONCLUSIONS: Our study shows that percutaneous LAAO may represent a feasible alternative strategy for stroke prevention, that can be safely performed in high-risk, multimorbid patients with high bleeding risk or contraindications to oral anticoagulation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Idoso Fragilizado , Humanos , Octogenários , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Clin Res Cardiol ; 111(8): 955-965, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35505123

RESUMO

BACKGROUND: Cerebral oxygen saturation (ScO2) can be measured non-invasively by near-infrared spectroscopy (NIRS) and correlates with cerebral perfusion. We investigated cerebral saturation during transfemoral transcatheter aortic valve implantation (TAVI) and its impact on outcome. METHODS AND RESULTS: Cerebral oxygenation was measured continuously by NIRS in 173 analgo-sedated patients during transfemoral TAVI (female 47%, mean age 81 years) with self-expanding (39%) and balloon-expanding valves (61%). We investigated the periprocedural dynamics of cerebral oxygenation. Mean ScO2 at baseline without oxygen supply was 60%. During rapid ventricular pacing, ScO2 dropped significantly (before 64% vs. after 55%, p < 0.001). ScO2 at baseline correlated positively with baseline left-ventricular ejection fraction (0.230, p < 0.006) and hemoglobin (0.327, p < 0.001), and inversely with EuroSCORE-II ( - 0.285, p < 0.001) and length of in-hospital stay ( - 0.229, p < 0.01). Patients with ScO2 < 56% despite oxygen supply at baseline had impaired 1 year survival (log-rank test p < 0.01) and prolonged in-hospital stay (p = 0.03). Furthermore, baseline ScO2 was found to be a predictor for 1 year survival independent of age and sex (multivariable adjusted Cox regression, p = 0.020, hazard ratio (HR 0.94, 95% CI 0.90-0.99) and independent of overall perioperative risk estimated by EuroSCORE-II and hemoglobin (p = 0.03, HR 0.95, 95% CI 0.91-0.99). CONCLUSIONS: Low baseline ScO2 not responding to oxygen supply might act as a surrogate for impaired cardiopulmonary function and is associated with worse 1 year survival and prolonged in-hospital stay after transfemoral TAVI. ScO2 monitoring is an easy to implement diagnostic tool to screen patients at risk with a potential preserved recovery and worse outcome after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Oxigênio , Saturação de Oxigênio , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Função Ventricular Esquerda
4.
Catheter Cardiovasc Interv ; 97(1): E146-E153, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32433818

RESUMO

BACKGROUND: Cerebral O2 saturation (ScO2 ) reflects cerebral perfusion and can be measured noninvasively by near-infrared spectroscopy (NIRS). OBJECTIVES: In this pilot study, we describe the dynamics of ScO2 during TAVI in nonventilated patients and its impact on procedural outcome. METHODS AND RESULTS: We measured ScO2 of both frontal lobes continuously by NIRS in 50 consecutive analgo-sedated patients undergoing transfemoral TAVI (female 58%, mean age 80.8 years). Compared to baseline ScO2 dropped significantly during RVP (59.3% vs. 53.9%, p < .01). Five minutes after RVP ScO2 values normalized (post RVP 62.6% vs. 53.9% during RVP, p < .01; pre 61.6% vs. post RVP 62.6%, p = .53). Patients with an intraprocedural pathological ScO2 decline of >20% (n = 13) had higher EuroSCORE II (3.42% vs. 5.7%, p = .020) and experienced more often delirium (24% vs. 62%, p = .015) and stroke (0% vs. 23%, p < .01) after TAVI. Multivariable logistic regression revealed higher age and large ScO2 drops as independent risk factors for delirium. CONCLUSIONS: During RVP ScO2 significantly declined compared to baseline. A ScO2 decline of >20% is associated with a higher incidence of delirium and stroke and a valid cut-off value to screen for these complications. NIRS measurement during TAVI procedure may be an easy to implement diagnostic tool to detect patients at high risks for cerebrovascular complications and delirium.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Projetos Piloto , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Acta Cardiol ; 76(6): 615-622, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32396499

RESUMO

BACKGROUND: Nutritional status predicts outcomes after TAVR. Predictive value of Prognostic Nutritional Index (PNI) was investigated in patients undergoing TAVR, and compared to other nutritional indexes. METHODS: A cohort of 114 patients undergoing TAVR in a high-volume centre was studied. A prospective 1-year follow-up was completed. PNI was estimated as follows: (10 × serum albumin[g/dl])+(0.005 × total lymphocytes [1000/µl]). One-year survival was compared in patients with PNI above vs below median; Kaplan-Meier curves were created. A multivariate analysis was used to assess predictive value of PNI for 1-year mortality. ROC curves were used to assess discrimination by PNI, and to compare it with Geriatric Nutritional Risk Index (GNRI) and Body Mass Index (BMI). RESULTS: Mean age was 82.2 years, 59.6% were male. Mean PNI was 46 ± 5. Pre-procedurally, no differences were found between patients with high vs. low PNI. One-year mortality was significantly higher in patients with low PNI values (19/57 vs. 4/57; p < .001). Complications did not differ. A higher PNI predicted 1-year survival, even after adjusting for clinical factors (model 1: HR 0.8, 95% CI 0.7-0.9, p < .0001) and laboratory parameters (NT-proBNP, IL-6, CRP, eGFR, cystatin C, haemoglobin) (model 2: HR 0.8, 95% CI 0.7-0.9, p < .05). ROC curves revealed a stronger predictive value for PNI (AUC 0.80) compared to GNRI (0.77) and BMI (0.6). The optimal cut-off for PNI was 45. CONCLUSION: PNI is a useful and practical nutritional marker reflecting malnutrition and inflammation prior to the intervention, and strongly predicts 1-year survival. PNI seems to be a better prognostic marker than BMI or GNRI after TAVR.


Assuntos
Avaliação Nutricional , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Catéteres , Feminino , Humanos , Masculino , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
6.
Clin Res Cardiol ; 110(5): 640-648, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33249517

RESUMO

AIMS: Stroke is a major complication after transcatheter aortic valve implantation (TAVI). Although multifactorial, it remains unknown whether the valve deployment system itself has an impact on the incidence of early stroke. We performed a meta- and network analysis to investigate the 30-day stroke incidence of self-expandable (SEV) and balloon-expandable (BEV) valves after transfemoral TAVI. METHODS AND RESULTS: Overall, 2723 articles were searched directly comparing the performance of SEV and BEV after transfemoral TAVI, from which 9 were included (3086 patients). Random effects models were used for meta- and network meta-analysis based on a frequentist framework. Thirty-day incidence of stroke was 1.8% in SEV and 3.1% in BEV (risk ratio of 0.62, 95% confidence interval (CI) 0.49-0.80, p = 0.004). Treatment ranking based on network analysis (P-score) revealed CoreValve with the best performance for 30-day stroke incidence (75.2%), whereas SAPIEN had the worst (19.0%). However, network analysis showed no inferiority of SAPIEN compared with CoreValve (odds ratio 2.24, 95% CI 0.70-7.2). CONCLUSION: Our analysis indicates higher 30-day stroke incidence after transfemoral TAVI with BEV compared to SEV. We could not find evidence for superiority of a specific valve system. More randomized controlled trials with head-to-head comparison of SEV and BEV are needed to address this open question.


Assuntos
Complicações Pós-Operatórias/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Humanos , Incidência , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
7.
Front Cardiovasc Med ; 7: 605257, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33330669

RESUMO

Background: Both EPO levels and anemia have shown prognostic value in several cardiac disorders. An observational study with a prospective follow-up was performed to investigate their independent prognostic roles in severe aortic stenosis. Methods: An up to 36-month follow-up of consecutive patients with severe aortic stenosis undergoing TAVR in a high-volume center was performed. Patients with eGRF <30 mL/min/1.73 m2 were excluded. EPO levels and/or anemia status and its association with mid-term mortality were assessed. Results: Out of 407, 360 met eligibility criteria. Median age was 83 years, with 71.4% having a NYHA class III/IV. Anemia was present in 51.9%, and iron deficiency in 52.8%. Median (IQR) EPO levels were 14.4 (9.30-24.30) mIU/mL. Median follow-up was 566 days. Anemia was associated with overall mortality (HR 2.40, 95% CI 1.51-3.80, p < 0.001). Higher logEPO levels were associated with mid-term mortality (HR 4.05, 95% CI 2.29-7.16, p < 0.001), even after adjusting for clinically and/or statistically relevant factors (multivariate HR 2.25, 95 CI 1.09-4.66, p = 0.029). Kaplan-Meier analyses showed early diverging curves for anemia vs. non-anemia, whereas curves for patients in various EPO level quartiles started to diverge at about 100 days, with differences consistently increasing during the subsequent entire follow-up period. Conclusions: Differently from anemia, which was a strong predictor for both early and late mortality in severe aortic stenosis after TAVR, independent prognostic value of EPO only emerged after post-TAVR recovery. EPO prognostic value was independent from anemia and mild-to-moderate renal dysfunction. High EPO levels could be useful to identify patients with severe aortic stenosis showing a compromised mid-term survival in spite of TAVR use and independently from early TAVR results.

8.
Case Rep Transplant ; 2018: 6585879, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29850365

RESUMO

Indication for combined cardiac surgery and orthotopic liver transplantation is rare and patients are at high risks. Individual surgical strategy must be developed since a general standard of such procedure does not exist. We report the case of a 45-year-old woman who underwent simultaneously modified Bentall procedure and orthotopic liver transplantation. Underlying diseases were end-stage polycystic liver, aneurysm of the ascending aorta, and severe aortic regurgitation. To avoid prolonged bypass times, both teams worked simultaneously. During cardiac reperfusion, time inferior vena cava stayed ligated while the cyst liver was explanted.

9.
Interact Cardiovasc Thorac Surg ; 24(6): 964-966, 2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28329239

RESUMO

Left ventricular thrombus is a frequent complication after myocardial infarction and is associated with high risk for arterial embolic complications. In addition to oral anticoagulation, surgical thrombectomy may be a promising treatment for large and mobile thrombus. We report the rare case of a 27-year-old patient who presented with a giant left ventricular thrombus after expanded and silent myocardial infarction caused by spontaneous dissection of the left anterior descending coronary artery. As conservative therapy by oral anticoagulation had failed, the thrombus was removed by performing left ventriculotomy.


Assuntos
Anomalias dos Vasos Coronários/complicações , Cardiopatias/etiologia , Infarto do Miocárdio/complicações , Trombectomia/métodos , Trombose/etiologia , Doenças Vasculares/congênito , Adulto , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico , Ecocardiografia Transesofagiana , Cardiopatias/diagnóstico , Cardiopatias/cirurgia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Infarto do Miocárdio/diagnóstico , Trombose/diagnóstico , Trombose/cirurgia , Doenças Vasculares/complicações , Doenças Vasculares/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...