Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Res Sq ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38464207

RESUMO

Background: Radiolabeled antibody 131I-omburtamab was administered intraventricularly in patients with leptomeningeal disease under an institutionally approved study (#NCT03275402). Radiation safety precautions were tailored for individual patients, enabling outpatient treatment based on in-depth, evidence-based recommendations for such precautions. The imperative advancement of streamlined therapeutic administration procedures, eliminating the necessity for inpatient isolation and resource-intensive measures, holds pivotal significance. This development bears broader implications for analogous therapies within the pediatric patient demographic. Methods: Intraventricular radioimmunotherapy (RIT) with 925-1850 MBq (25-50 mCi) of 131I-omburtamab was administered via the Ommaya reservoir, in designated rooms within the pediatric ambulatory care center. Dosimeters were provided to staff involved in patient care to evaluate exposure during injection and post-administration. Post-administration exposure rate readings from the patient on contact, at 0.3 m, and at 1 m were taken within the first 30 minutes, and the room was surveyed after patient discharge. Duration of radiation exposure was calculated using standard U.S. Nuclear Regulatory Commission (US NRC) regulatory guidance recommendations combined with mean exposure rates and whole-body clearance estimates. Exposure rate measurements and clearance data provided patient-specific precautions for four cohorts by age: < 3 y/o, 3-10 y/o, 10-18 y/o, and 18+. Results: Post-administration exposure rates for patients ranged from 0.16-0.46 µSv/hr/MBq at 1 ft and 0.03-0.08 µSv/hr/MBq at 1 m. Radiation exposure duration ranged from 1-10 days after release for the four evaluated cohorts. Based on the highest measured exposure rates and slowest whole-body clearance, the longest precautions were approximately 78% lower than the regulatory guidance recommendations. Radiation exposure to staff associated with 131I-omburtamab per administration was substantially below the annual regulatory threshold for individual exposure monitoring. Conclusion: 131I-omburtamab can be administered on an outpatient basis, using appropriate patient-based radiation safety precautions that employ patient-specific exposure rate and biological clearance parameters. This trial is registered with the National Library of Medicine's ClinicalTrials.gov. The registration number is NCT03275402, and it was registered on 7 September 2017. The web link is included here. https://clinicaltrials.gov/study/NCT03275402.

2.
J Vasc Interv Radiol ; 34(9): 1556-1564.e4, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37201655

RESUMO

PURPOSE: To evaluate the yttrium-90 (90Y) activity distribution in biopsy tissue samples of the treated liver to quantify the dose with higher spatial resolution than positron emission tomography (PET) for accurate investigation of correlations with microscopic biological effects and to evaluate the radiation safety of this procedure. MATERIALS AND METHODS: Eighty-six core biopsy specimens were obtained from 18 colorectal liver metastases (CLMs) immediately after 90Y transarterial radioembolization (TARE) with either resin or glass microspheres using real-time 90Y PET/CT guidance in 17 patients. A high-resolution micro-computed tomography (micro-CT) scanner was used to image the microspheres in part of the specimens and allow quantification of 90Y activity directly or by calibrating autoradiography (ARG) images. The mean doses to the specimens were derived from the measured specimens' activity concentrations and from the PET/CT scan at the location of the biopsy needle tip for all cases. Staff exposures were monitored. RESULTS: The mean measured 90Y activity concentration in the CLM specimens at time of infusion was 2.4 ± 4.0 MBq/mL. The biopsies revealed higher activity heterogeneity than PET. Radiation exposure to the interventional radiologists during post-TARE biopsy procedures was minimal. CONCLUSIONS: Counting the microspheres and measuring the activity in biopsy specimens obtained after TARE are safe and feasible and can be used to determine the administered activity and its distribution in the treated and biopsied liver tissue with high spatial resolution. Complementing 90Y PET/CT imaging with this approach promises to yield more accurate direct correlation of histopathological changes and absorbed dose in the examined specimens.


Assuntos
Neoplasias Colorretais , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Microtomografia por Raio-X , Autorradiografia , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Radioisótopos de Ítrio/efeitos adversos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Biópsia Guiada por Imagem , Microesferas
3.
Radiat Prot Dosimetry ; 198(19): 1476-1482, 2022 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-36138119

RESUMO

External dose rates were measured 1 m away from 230 Lu-177 patients to characterise the variability in normalised dose rates as a function of administered activity, body mass index (BMI) and sex. The largest dose rate observed was 0.07 mSv/h associated with an administered activity of 7.2 GBq. Substantial variability was found in the distribution of the normalised dose rate associated that had an average of 0.0037 mSv/h per GBq and a 95% confidence interval of 0.0024-0.0058 mSv/h per GBq. Based on this study, estimating the patient dose rate based on the Lu-177 gamma exposure factor overestimates the dose rate by a factor of 2. A statistically significant inverse relationship was found between the patient dose rate and patient BMI and an empirically derived equation relating these two quantities was reported. On average, male patient dose rates were 3.5% lower than female dose rates, which may be attributed to the larger average BMI of the male patient group.


Assuntos
Lutécio , Radioisótopos , Humanos , Masculino , Feminino , Índice de Massa Corporal , Estudos de Coortes
4.
Int J Radiat Biol ; 98(4): 593-599, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-30810447

RESUMO

BACKGROUND: The National Council on Radiation Protection and Measurements (NCRP) is coordinating an expansive epidemiologic effort entitled the Million Person Study of Low-Dose Radiation Health Effects (MPS). Medical workers constitute the largest occupational radiation-exposed group whose doses are typically received gradually over time. METHODS: A unique opportunity exists to establish an Institutional Review Board/Privacy Board (IRB/PB) approved, retrospective feasibility sub-cohort of diseased Memorial Sloan Kettering Cancer Center (MSK) medical radiation workers to reconstruct occupational/work history, estimate organ-specific radiation absorbed doses, and review existing publicly available records for mortality from cancer (including leukemia) and other diseases. Special emphasis will be placed on dose reconstruction approaches as a means to provide valid organ dose estimates that are as accurate and precise as possible based on the available data, and to allow proper evaluation of accompanying uncertainties. Such a study that includes validated dose measurements and information on radiation exposure conditions would significantly reduce dose uncertainties and provided greatly improved information on chronic low-dose risks. RESULTS: The feasibility sub-cohort will include deceased radiation workers from MSK who worked during the nearly seventy-year timeframe from 1946 through 2010 and were provided individual personal radiation dosimetry monitors. A feasibility assessment focused on obtaining records for about 25-30,000 workers, with over 124,000 annual doses, including personnel/work histories, specific dosimetry data, and appropriate information for epidemiologic mortality tracing will be conducted. MSK radiation dosimetry measurements have followed stringent protocols complying with strict worker protection standards in order to provide accurate dose information for radiation workers that include detailed records of work practices (including specific task exposure conditions, radiation type, energy, geometry, personal protective equipment usage, badge position, and missed doses), as well as recorded measurements. These dose measurements have been ascertained through a variety of techniques that have evolved over the years, from film badges to thermoluminescent dosimetry technology to optically stimulated luminescent methodologies. It is expected that individual total doses for the sub-cohort will have a broad range from <10 mSv to > =1000 mSv. CONCLUSIONS: MSK has pioneered the use of novel radiation diagnostic and therapeutic approaches over time (including initial work with x-rays, radium, and radon), with workplace safety in mind, resulting in a variety of radiation worker exposure scenarios. The results of this feasibility sub-cohort of deceased radiation workers, and associated lessons learned may potentially be applied to an expanded multicenter study of about 170,000 medical radiation worker component of the MPS.


Assuntos
Proteção Radiológica , Estudos de Viabilidade , Humanos , Doses de Radiação , Proteção Radiológica/métodos , Radiometria/métodos , Estudos Retrospectivos
5.
J Nucl Med Technol ; 50(1): 10-16, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34750237

RESUMO

CE credit: For CE credit, you can access the test for this article, as well as additional JNMT CE tests, online at https://www.snmmilearningcenter.org Complete the test online no later than March 2025. Your online test will be scored immediately. You may make 3 attempts to pass the test and must answer 75% of the questions correctly to receive Continuing Education Hour (CEH) credit. Credit amounts can be found in the SNMMI Learning Center Activity. SNMMI members will have their CEH credit added to their VOICE transcript automatically; nonmembers will be able to print out a CE certificate upon successfully completing the test. The online test is free to SNMMI members; nonmembers must pay $15.00 by credit card when logging onto the website to take the test.α-emitting radionuclides provide an effective means of delivering large radiation doses to targeted treatment locations. 223RaCl2 is Food and Drug Administration-approved for treatment of metastatic castration-resistant prostate cancer, and 225Ac (225Ac-lintuzumab) radiolabeled antibodies have been shown to be beneficial for patients with acute myeloid leukemia. In recent years, there has been increasing use of α-emitters in theranostic agents with both small- and large-molecule constructs. The proper precautionary means for their use and surveying documentation of these isotopes in a clinical setting are an essential accompaniment to these treatments. Methods: Patient treatment data collected over a 3-y period, as well as regulatory requirements and safety practices, are described. Commonly used radiation instruments were evaluated for their ability to identify potential radioactive material spills and contamination events during a clinical administration of 225Ac. These instruments were placed at 0.32 cm from a 1.0-cm 225Ac disk source for measurement purposes. Radiation background values, efficiencies, and minimal detectable activities were measured and calculated for each type of detector. Results: The median external measured dose rate from 223RaCl2 patients (n = 611) was 2.5 µSv h-1 on contact and 0.2 µSv h-1 at 1 m immediately after administration. Similarly, 225Ac-lintuzumab (n = 19) patients had median external dose rates of 2.0 µSv h-1 on contact and 0.3 µSv h-1 at 1 m. For the measurement of 225Ac samples, a liquid scintillation counter was found to have the highest overall efficiency (97%), whereas a ZnS α-probe offered the lowest minimal detectable activity at 3 counts per minute. Conclusion: In this article, we report data from 630 patients who were undergoing treatment with the α-emitting isotopes 223Ra and 225Ac. Although α-emitters have the ability to deliver a higher internal radiation dose to the exposed tissues than can other unsealed radionuclides, they typically present minimal concerns about external dose rate. Additionally, α-radiation can be efficiently detected with appropriate radiation instrumentation, such as a liquid scintillation counter or ZnS probe, which should be prioritized when surveying for spills of α-emitters.


Assuntos
Neoplasias da Próstata , Radioisótopos , Humanos , Masculino , Radioisótopos/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...