1.
Sci Rep ; 11(1): 10958, 2021 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-34040095

RESUMO

To propose a new method of reducing the scan length of head trauma while keeping the diagnostic efficiency of the examination in order to develop DRL in an African context. This is a retrospective single-center study including 145 patients who had cranial examinations on a 64-barettes scanner. All head trauma cases were selected. The interpretations of these CT scanners by the three radiologists of the service were noted to determine the acquisition limit. All patient acquisition lengths have been recorded. The acquisition limit for head trauma ended in clinical routine at cervical spine 4 (C4). The average scan length was 23.03 cm. Out of the CT scan results for 145 patients, only 2 (1.37%) had a C3 level cervical spine fracture and 2 (1.37%) at C4. By respecting the principles of radiation protection, this result has shown us that it is possible to limit the acquisition length of the CT scanners indicated for head trauma. The limit of the optimized scan length that we proposed is at cervical spine 2 (98.62%). Now, all head trauma are limited on cervical vertebra 2 in our hospital. The use of this new method is beneficial when the clinical indication of the examination and the type of trauma (multi-trauma) are taken into account. Based on the principles of radiation protection and the clinical indication for the examination, reducing the scan length from C4 to C2 is an effective way to reduce the dose absorbed by the patient.


Assuntos
Vértebras Cervicais/diagnóstico por imagem , Traumatismos Craniocerebrais/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Lesões do Pescoço/diagnóstico por imagem , Adolescente , Adulto , Idoso , Camarões , Vértebras Cervicais/efeitos da radiação , Criança , Pré-Escolar , Feminino , Hematoma Epidural Craniano/diagnóstico por imagem , Hematoma Subdural/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/efeitos adversos , Tomografia Computadorizada Multidetectores/ética , Órgãos em Risco , Doses de Radiação , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Proteção Radiológica/legislação & jurisprudência , Estudos Retrospectivos , Fraturas Cranianas/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Ferimentos não Penetrantes/diagnóstico por imagem , Adulto Jovem
2.
Sci Rep ; 11(1): 4663, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33633210

RESUMO

There is currently no Pediatric Regulatory Diagnostic Reference Level (DRL) in Cameroon to standardize protocols in hospitals. France, a European country, has DRL allowing them to optimize their examination protocol. For the sake of radiation protection, we have proposed to evaluate the dose and acquisition parameters delivered to our pediatric patients to optimize the protocols used. We also compared the 75th percentile values of dose parameters by acquisition between the three hospitals to Diagnostic Reference Level (DRL) of France. In this retrospective and evaluative multicenter study, a total of 320 patients who had at least one cranial CT scan were enrolled from three medical centers. The CT acquisition parameters including tube potential (kV), tube current (mA), slice Thickness (T), spiral or sequential scanning techniques, volume CT dose index (CTDIvol), and dose length product (DLP) were analyzed. CTDIvol values in our centers were found up to 17.42%, 46.01%, 21.56% respectively for children aged 1-4 higher than values of France's DRL. For those aged 5-9, we obtained 44.58%, 43.15%, 42.21% respectively. In addition, for children aged 10-14 there are also up to 47.73%, 44.11%, 46.39% respectively higher than values of France's DRL. It is similary for DLP values. The study showed a significant dosimetric overshoot compared to the France's DRL and prompted us to make corrections to the protocols used and to a more rigorous monitoring of the principles of radiation protection and optimization rules in pediatric computed tomography in our hospitals. Our results have led us to make changes to our protocols which are the subject of a new dosimetric evaluation. The development of DRL for improving the pediatric CT scan in our country is necessary to optimize our protocols. Our results have led us to make changes to our protocols which are the subject of a new dosimetric evaluation. It would be necessary to set up a quality control structure in Cameroon and their applications in current practice.


Assuntos
Encéfalo/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Humanos , Lactente